Raw material variability is the reason two batches made to the same recipe, on the same line, by the same team, do not perform the same. It is also the reason a process scientist holding two low-viability batches and a stack of certificates of analysis feels stuck: every certificate says pass. The mistake hiding in that feeling is treating a specification as a description of the process when it is only a threshold — a lot at the very top of its allowed range and a lot in the middle both read "within specification", and your cells do not read the certificate. The useful question is not whether a lot was in specification but where in its range it sat, and which other batch took the same lot. That is a comparison across every material of two batches, which is a genealogy query rather than a certificate review, and it is the comparison Botminds' Manufacturing Batch Analytics runs in one click.
The worked example is sample data in the product: a fictional autologous CAR-T therapy on Line C2 at a fictional plant in Leiden, with a fictional supplier called Halvern. The published research and the regulations are real and linked where they appear.
Two outliers, every material compared, one lot shared
68.9%
viability at harvest on CRV-26-0431 — under the 70% release limit
72.4%
on CRV-26-0418 — under the 75% action limit
1lot
shared by the two batches across every raw material compared: culture medium MED-24-0917
81.2%
in-process viability on day 6 of a third batch already using the same lot
Why does an in-specification lot still move the output?
Because a specification encodes what is acceptable, and a process responds to what is actual. The two are related but they are not the same statement. A medium specification of 280 to 320 mOsm/kg says that the supplier and the manufacturer agreed, at some point, that anything inside that band would not cause a problem they could foresee. It says nothing about whether the cells grow identically at 296 and at 318.
There are three ordinary mechanisms behind that. The first is simple dose-response: a culture parameter can have a steady effect across the whole allowed band, so the edges of the specification behave measurably differently from the middle. The second is interaction: a lot at the top of one range may be harmless on its own and matter when combined with a second parameter also at the top of its range. The third is that specifications are often inherited — set at a scale, a cell line or a supplier that has since changed — and nobody re-derives them because every lot keeps passing.
None of this makes the specification wrong. It makes the specification an insufficient question. A release decision needs a pass mark; an investigation needs a position.
Specification limits are pass marks; your process has a response curve
The practical consequence is that an investigation should treat each incoming attribute as a continuous variable, not a binary one. Two lots that both pass can sit at opposite ends of their band, and when a batch goes wrong the first thing worth knowing is whether its materials were unusual for your plant — not whether they were unusual for the specification.
"Unusual for your plant" is a statement about your own receipt history. If your last thirty lots of a medium arrived between 294 and 304 mOsm/kg and one arrives at 318, that lot is an outlier by your own experience even though it is comfortably inside a 280 to 320 band. That comparison requires receipt values to be stored as numbers rather than scanned into a certificate folder, which is a common blocker to doing any of this.
Where a received value sits in its range, written out
The position
(received − lower limit) ÷ (upper limit − lower limit)
A number between 0 and 1. The middle of the band is 0.50; a plant can set its own flag — above 0.85 or below 0.15, say — for lots that pass but deserve a look.
Incoming quality
The suspect lot
(318 − 280) ÷ (320 − 280) = 0.95
Culture medium MED-24-0917, received at 318 mOsm/kg against a 280–320 specification: 95% of the way up its allowed band.
Sample data in the product
The other lots
(296 − 280) ÷ 40 = 0.40 … (302 − 280) ÷ 40 = 0.55
The medium lots around it ran 296–302 mOsm/kg — between 40% and 55% of the band. The suspect lot is not near them.
Sample data in the product
What it is not
position ≠ cause
A position is a lead. On three batches it is a correlation, and correlation on three points is a reason to look, never a root cause.
The investigator
The published evidence: one material as the major source of variability
This is not a hunch. A 2025 study of commercial antibody manufacture, published in Biochemistry and Biophysics Reports, states the general problem in its abstract: "Variability in the compositions of these complex raw materials can significantly impact product yields." The specific finding is sharper. Investigating their own commercial process, the authors report that "Analysis of the cell growth process identified a single raw material (RM) as the major contributor to variability in productivity during commercial antibody production".
Read that twice if you own a process. Not a contributing factor among many — the major contributor, for a product in commercial manufacture, from a material that was being accepted lot after lot. The study went on to build predictive models from infrared spectra of incoming lots: forty-one lots of the material were screened on receipt, of which twelve were used for one product and eighteen for another, with five used in both. The useful lesson for a plant that is not going to build spectral models tomorrow is the simpler one underneath: the material was identified as the dominant source of variability by looking across lots and batches, not by reading any one certificate.
The same paper notes why the variability exists at all: "Raw material variability can result from source location, production process, material age, and likely other conditions". Three of those four are invisible on a certificate of analysis, and the fourth — age — is often recorded somewhere nobody joins to batch performance.
Where variability comes in: source, process, age — and media preparation itself
There is a fifth source that sits inside the plant's own four walls, and it is often investigated last. Media prepared on site from powder is not a fixed article; it is the output of a process with its own parameters. A 2019 study in Engineering in Life Sciences ran a designed experiment over media preparations, varying temperature, specific power input and preparation time, and found that the routine quality indicators moved with them: "The P-media quality indicators which are typically used in industrial media preparation such as osmolality and pH as well as the pCO2 concentration at the end of the media preparations were all affected by temperature, specific power input, and preparation time".
The authors' conclusion is the part worth carrying into an investigation: "The presented results reveal the need for online spectroscopic methods during the preparation process and show that media variability can already be introduced by variation in media preparation parameters, with a potential impact on scale-up to a commercial manufacturing process." In other words, an osmolality difference between two batches may have arrived with the supplier's lot, or it may have been created on site during preparation. Those are different findings with different corrective actions, and a certificate review cannot distinguish them.
Practically, that means an investigation into a suspect material should always ask when and how the medium was prepared, and compare preparation records alongside the incoming certificate. If preparation parameters are not recorded to a resolution that would show a difference, that gap is itself a finding.
Reading a certificate of analysis as a position in a range, not a pass mark
Changing how certificates are read costs nothing and changes what investigations can see. The two readings below use the same document and reach different places.
A pass-or-fail certificate review against a position-in-range review
Pass-or-fail review: Does every attribute fall inside its specification?
Position-in-range review: Where inside its specification does each attribute fall, and how does that compare with our own receipt history?
Pass-or-fail review: A disposition: accepted. Often the only thing that reaches a system as data.
Position-in-range review: The numeric value of each attribute, with its limits, against the lot code.
Pass-or-fail review: A failing lot, and nothing else.
Position-in-range review: A drifting supplier, an unusual lot, and a lot shared by two bad batches.
Pass-or-fail review: None; it is what most plants already do.
Position-in-range review: Typing or extracting the values on receipt. The cost is one data-entry habit, not a system.
Pass-or-fail review: Explain any batch.
Position-in-range review: Prove causation. It produces a candidate, which then needs a designed check.
Pass-or-fail review: Release of the incoming lot — where a pass mark is exactly the right instrument.
Position-in-range review: Investigation and trending — where a pass mark is the wrong instrument.
There is a limit worth stating. Most certificate values come from the supplier's own laboratory, and 21 CFR 211.84 allows exactly that — "In lieu of such testing by the manufacturer, a report of analysis may be accepted from the supplier of a component, provided that at least one specific identity test is conducted on such component by the manufacturer, and provided that the manufacturer establishes the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals." A position-in-range reading inherits whatever measurement variability the supplier's method has, so a 318 against a history of 296 to 302 is a lead to check, not a measurement to build a conclusion on.
The comparison that finds it: every lot of two outlier batches, side by side
The move that turns a pile of certificates into a candidate is mechanical: take two batches that both went wrong, list every material lot, every piece of equipment and every shift either used, and find the rows that match. It is the simplest possible analysis and it is often skipped, because assembling two complete bills of materials from four systems by hand can take most of a day.
In the sample data, two batches sat below the lower control limit of 83.4%: CRV-26-0431 at 68.9% viability at harvest, under the 70% release limit, and CRV-26-0418 at 72.4%, under the 75% action limit. Comparing every raw material lot of the two found exactly one shared: culture medium MED-24-0917 from Halvern, received at 318 mOsm/kg — the top of its 280 to 320 range, where the other lots ran 296 to 302.
The shared-lot comparison in Manufacturing Batch Analytics: every material, one match
Starting material · apheresis
CRV-26-0431CV-4471-LD
CRV-26-0418A different donation
ReadingAutologous: one donation per batch, so never shared and never a shared cause.
Selection beads
CRV-26-0431SEL-3307
CRV-26-0418A different lot
ReadingDifferent lots.
Lentiviral vector
CRV-26-0431LVV-2241
CRV-26-0418LVV-2238
ReadingDifferent lots; copy number stayed inside the 5.0 limit on both.
Culture medium
CRV-26-0431MED-24-0917 · Halvern
CRV-26-0418MED-24-0917 · Halvern
ReadingThe one row that matches. Received at 318 mOsm/kg, the top of its 280–320 range.
Activation reagent
CRV-26-0431ACT-7730
CRV-26-0418A different lot
ReadingDifferent lots; a plausible suspect ruled out by the comparison itself.
Cytokines IL-7 / IL-15
CRV-26-0431CYT-1182
CRV-26-0418A different lot
ReadingDifferent lots, from different receipts.
Cryomedium
CRV-26-0431CRYO-5521
CRV-26-0418A different lot
ReadingDifferent lots; CRV-26-0431’s is not the lot in the separate supplier recall.
One row the comparison does not cover is worth adding by hand. Equipment, line, operator and shift are shared by almost everything on a single-line process — both outliers ran on Line C2, and so did the eighteen batches that behaved normally — so a shared row only becomes a lead when the batches performing normally did not also have it. That filter is what separates a candidate from a coincidence, and it applies to materials as much as to equipment.
Two cautions belong with the result, and the page would be dishonest without them. First, the comparison produces a candidate, not a cause: a shared lot between two bad batches is exactly what you would expect to find by chance if the two batches shared many materials. Second, the osmolality difference is a correlation observed on a handful of batches — two at harvest and one still in expansion. It is the lead the comparison produced. Calling it the root cause in a deviation would be asserting something the data cannot support, and a reviewer should push back if anyone does.
One batch's genealogy, from apheresis to drug product, with viability by medium lot

The chart the two outliers came from, with the rule that marked them

Viability at harvest by culture medium lot, over the last twenty batches
What the rules already require you to do about variability
For advanced therapies the expectation is explicit and unusually direct. The European Commission's GMP guidelines for ATMPs state that "The quality of starting and raw materials is a key factor to consider in the production of ATMPs. Particular attention should be paid to avoiding contamination and to minimising as much as possible the variability of the starting and raw materials."
"Minimising as much as possible the variability" is not satisfied by accepting lots that pass. Minimising variability requires knowing what the variability is, which requires numbers, over time, by lot — the position-in-range habit described above, kept as a series. A firm that can show a plot of an incoming attribute against its own history, and a supplier conversation that followed from it, is meeting that expectation. A firm with a folder of passed certificates has evidence of acceptance, not of minimisation.
The same logic connects raw material work to process verification: incoming material quality is one of the data families a continued verification programme is expected to trend, and a shift in a supplier's lots shows up there before it shows up in a deviation. Continued process verification, batch by batch sets out where the limits in this page's ladder come from.
Can you reject a lot that meets its specification?
Commercially it depends on your contract; technically there is nothing stopping you from quarantining and investigating a lot that passes, and plenty of reason to. The relevant constraint is the opposite one: having accepted a lot, you may not use the specification as a defence if your own data says it behaved differently. The honest positions are these.
You can hold a passing lot pending investigation, as a precautionary measure your quality system records. You can decline to use a lot on a specific product while using it elsewhere, if your data supports the distinction. You can tighten your own incoming specification below the supplier's, which is a change control and a supplier conversation rather than a rejection. What you cannot do is quietly set aside a lot without a record, because the lot's status is part of the material's history and a later investigation will need to know what you did and why.
What you should not do is reject on a single correlation. The sample data has one shared lot across two batches and one suspicious receipt value. That is enough to hold, sample and review. It is not enough to tell a supplier its material is out of control, and a supplier relationship spent on a lead that does not survive the next ten lots is a real cost.
What to do before the next feed: the hold, the sample, the review
The reason this kind of analysis has to be fast is that processes do not wait. In the sample data a third batch, CRV-26-0436, was already in expansion using the same medium lot, at 81.2% in-process viability on day 6, with its next feed due at 14:00. The firm's own procedure, SOP-MFG-0211 section 6.4, asks for a raw material lot review before the next feed. An analysis that takes three days produces a finding about a batch that has already been fed.
Seven checks on an incoming lot that a pass-or-fail release does not make
- Record the numeric value of every attribute, not just the disposition
A stored number can be plotted; a stored "accepted" cannot. This is the one change that makes all the others possible.
- Compare each value with your own receipt history, not only with the limits
A lot at 318 in a 280–320 band is in specification and unusual for a plant whose last lots ran 296–302. Both statements are true and only one is useful in an investigation.
- Record where the lot sits in its band as a number
Position makes lots comparable across attributes with different units, and makes a drifting supplier visible before any lot fails.
- Capture the preparation parameters when media are made on site
Published work has shown osmolality, pH and dissolved carbon dioxide moving with preparation temperature, power input and time — variability you created, not variability you received.
- Keep material age and storage history with the lot
Age is named in the literature as a source of variability and is rarely joined to batch performance, because it lives in a warehouse system.
- Check that a shared row is not shared with the good batches too
The line, the operator and the vessel are often common to everything. A shared material is only a lead if the in-range batches did not use it.
- Decide what would change your mind before you look
Write down the check that would confirm or kill the lead — the next batch on the same lot, a retained sample, a spiking study — and run it. A lead nobody tried to refute becomes a conclusion by default.
In the product, the comparison, the chart and the procedure passage come back inside one session, each with the query or the cited section beside it, and a person confirms the answer before it is saved. The deviation is drafted with a proposed classification, and the quality unit decides the class; the hold on a raw material lot needs the Qualified Person's signature. What the trace behind that comparison actually walks is set out in the two walks of a lot genealogy. To run the comparison on your own batches, start from Manufacturing Batch Analytics.
Questions people ask
What causes lot-to-lot variability in cell culture media?
Published work points to the material's own origins and handling — a 2025 study of commercial antibody manufacture lists source location, production process and material age among the causes — and to the preparation step itself. A 2019 designed experiment on media preparation found osmolality, pH and end-of-preparation carbon dioxide all affected by temperature, specific power input and preparation time, so some of the variability a plant sees in its medium is created on site rather than received.
How do you investigate a raw material as a root cause?
Start with the comparison rather than the certificates: list every material lot, vessel, line and shift of the affected batches and find the rows they share but the unaffected batches do not. Then position the suspect attribute within its range against your own receipt history. Then design a check that could refute the lead — the next batch on the same lot, a retained sample, or a deliberate test — before writing anything as a cause.
What does osmolality tell you about a medium lot?
It is a cheap, routine indicator of the medium's overall composition and preparation, which is why it is used as a quality indicator in industrial media preparation. It is an indicator, not a mechanism: a lot at the top of its osmolality range may differ in several components at once, and osmolality is the symptom that is easy to measure. Treat an unusual value as a reason to look at the composition, not as the explanation.
Does GMP require you to minimise raw material variability?
For advanced therapy medicinal products, yes in those words: the European Commission's ATMP guidelines say particular attention should be paid to "minimising as much as possible the variability of the starting and raw materials". For other products the requirement is less direct but points the same way, through incoming control, supplier qualification and the expectation that process data including incoming material quality is trended.
Can you reject an in-specification material lot?
You can hold it, investigate it, decline to use it on a particular product, or tighten your own incoming specification below the supplier's — all with a record of what you did and why. What you should not do is reject on a single correlation across two batches: that is enough to hold and sample, not enough to conclude. And whatever you decide, the lot's status has to be recorded, because a later investigation will need it.
How do you compare two batches to find a shared lot?
Build both batches' complete bills of material from the lot links rather than from the batch records alone, add equipment, line, operator and shift, and intersect them. Then subtract the rows that the batches performing normally also share. The remainder is the candidate list. Done by hand across four systems this can take most of a day; done from a genealogy that already holds the links it is one query.