SearchWater Operations

Water Operator Knowledge Search

Water operator knowledge search that answers from your SOPs and permit, and checks each dose against the permit before you set it

See one case, screen by screen ↓
Watch with transcript →

Built forTreatment operatorsSenior operatorsProcess scientistsCompliance managersNetwork technicians

The Problem Today

On a storm night one operator works out a dose from four scattered sources, and nothing checks it against the permit.

21%
of water utility staff can retire within 5 years published

Four places, searched at night

  • SOP
  • Permit
  • Jar test
  • Manual
  • The storm card is out of dateWritten for water with more alkalinity than the river has now
  • A phone call for each doseEach change confirmed with the on-call supervisor

The Solution

  1. Ask in plain words, on shiftLive turbidity, pH, alkalinity and flow read from the plant, never written to it
  2. Dose worked out from the sourcesJar test, SOP table and chemical strength give the dose and pump rate, with sources
  3. Checked against the permitAluminum, pH, turbidity and chlorine predicted, with a breach shown in red
  4. The operator sets the doseSigned into the shift log. A red dose needs the on-call supervisor

Built-in controls

  • Permit text quoted word for word
  • Read-only: nothing writes to the plant
  • Expert notes used only once approved

What You Get

Fewer storm nights end above a permit limit, and the senior operators' know-how stays after they retire.

3 min
to work out, check and log one storm-night dose, down from 48 our estimate
  • Fewer late-night callsA dose with its sources at the control desk while the river rises
  • Storm know-how keptSenior operators' notes pinned to the clause they explain
  • Old storm cards foundReplaced documents still in use on the plant floor are flagged
In short

What is Water Operator Knowledge Search?

It is a search tool for treatment operators and network technicians. It answers from the works' own SOPs, equipment manuals, permit, jar tests and incident reports, and each line has a source. A chemical dose comes back as a worked calculation with a permit check beside it. A procedure comes back as numbered steps with the SOP and permit text quoted.

How to choose AI solutions for utilities →

Updated

The problem

A night operator works out a storm dose from four places, and nothing checks it

At night one operator runs the water treatment works alone. When a storm hits, the river turns muddy fast. Its turbidity, how cloudy it is, measured in NTU, can rise from 6 to 45 in a few hours. The operator must then change the dose of alum, the chemical that clumps the dirt so the filters can catch it. This step is called coagulation. The answer to “what dose now?” is spread out. The 46-page coagulation SOP, or standard operating procedure, is on a shared drive. The permit sits in the compliance team's library. The last jar test, a bench trial of doses, is in a lab spreadsheet. The pump's chemical strength is in an equipment manual. And a laminated storm card is taped by the dosing panel. Too little alum, and dirt carries through to the filters. Too much in soft water, and the pH crashes, so aluminum stays dissolved and passes the filters.

The person who knows how the river behaves is the senior operator on call, who retires in 66 days. Most of that knowledge is not written down. The storm card also no longer fits the water. It was written for raw-water alkalinity of about 55 mg/L. Since water from an upland source was blended in, it has been 30 to 38. A few years ago a night operator followed the card and raised alum from 20 to 60 mg/L in one step. Aluminum in the treated water then stayed above the permit limit for 5 h 20 min.

typical21%of water utility staff can retire within 5 years
Where the minutes go in one storm-night dose decisionestimated
By hand48 minutes
With the solution3 minutes
  • Finding the current SOP clause and dose-correction table8 → 0.1 min
  • Finding the latest jar test for this turbidity level5 → 0.1 min
  • Working out the pump rate, alkalinity used and pH by hand6 → 0.2 min
  • Checking the dose against the permit limits5 → 0.1 min
  • Calling the on-call supervisor to confirm20 → 2 min
  • Writing the shift-log entry4 → 0.5 min

Our estimate for one coagulant dose change on a night shift, in minutes, by hand and with the solution.

How it works

A plain question in, a cited dose and a permit check out

What comes in
Sources inThe works’ document library · SOPs, manuals, permits, jar tests, incidents
Agents at work
Question readerworks, chemical, live plant
Then
Procedure finder
Dose calculator
Then
Permit checker9 limits, warns first
Incident matcher
Then
Knowledge keepershift log and expert notes
A person decides
Treatment operatorsets the dose, signs
What comes out
Worked, cited dose
Permit check
Signed shift-log entry
One case, step by step

Water operator knowledge search on a storm night, as the river rises

A treatment works on a river supplies 38 ML/d, or 38 million liters a day. It is the night shift. One treatment operator is alone in the control room, and the senior operator is on call. Here is what happens, screen by screen, in the working solution.

A worked example on sample data. Names, IDs and figures on the screens and in this section come from the demo.

  1. 0119:00 to 02:30

    A dry-weather handover, then the river rises

    Treatment operator

    The day operator hands over at 19:00. The weather is dry, alum is at 18 mg/L, all 6 filters run, and a storm is due after 23:00. The shift log fills from the plant historian and the weather feed. Intake turbidity reads 6 NTU at 22:00 and 19 at 00:40. The settled water alarm sounds at 2.5 NTU at 01:50. By 02:30 the intake reads 45 NTU. Alum is still on the dry-weather setting, 18 mg/L and 44 L/h on the pump.

    Handover: “Dry weather. Alum 18 mg/L, all 6 filters in service, filter 4 due a wash. Storm forecast after 23:00.”

  2. 0202:41

    “Coagulant dose at 45 NTU?”, answered as a worked dose

    Treatment operator

    The operator asks in their own words. A live, read-only strip from the plant historian sits above the answer. The intake reads 45 NTU, raw pH 7.3 and alkalinity 34 mg/L. Water is at 9.2 °C, flow is 38.0 ML/d and settled water is 2.9 NTU. The answer is to raise alum to 38 mg/L, or 93 L/h on the pump. Each line of the working has a source. The latest jar test found 35 mg/L best at 40 NTU. SOP Table 2 adds 0.6 mg/L per NTU above that. Then 38 g/m³ × 1,583 m³/h ÷ 645 g/L gives 93.3 L/h.

    “Raise alum to 38 mg/L · Liquid aluminum sulfate on the dosing pump, for raw water at 45 NTU and 38.0 ML/d”

  3. 037.8 seconds

    The SOP, the permit, the jar test and the plant, read in order

    The six agents

    The run log shows each step. The question reader took the works, the stage and the chemical from the question and the live readings. The procedure finder found the coagulation SOP, revision 9, §5.3, §5.4, §5.6 and Table 2. It also found the equipment manual §4.2 and flagged the storm card as replaced. The dose calculator split the change into two steps under the step-size rule. The permit checker checked 9 limits, all inside. The senior operator's approved note sits beside the jar-test curve.

    The senior operator's approved note: “Above 40 NTU, step the alum up in tens and watch the coagulation pH, not the settled turbidity.”

  4. 04Try the storm card

    The storm card says 55. The permit check turns red

    Treatment operator

    At 38 mg/L every meter is green. Treated-water aluminum is 0.060 mg/L, against the permit's 0.200 and a works target of 0.100. Filtered turbidity is 0.12 NTU against 0.30. The pH is 6.7, inside the SOP range of 6.4 to 6.9, with 15 mg/L of alkalinity left. The operator slides the dose to the storm card's 55. Aluminum goes to 0.230 mg/L and pH to 6.2. Alkalinity left drops to 6.5, below the minimum of 10.

    “Breaks permit condition 4.2: aluminum 0.230 mg/L. Also outside the SOP: alkalinity 6.5 mg/L.”

  5. 05Log 55 instead?

    A dose outside the permit needs the supervisor

    Permit checker

    If the operator tries to log the red dose, the solution stops the entry. It offers to send the dose to the on-call senior operator to decide, with the permit check attached. This rule is locked on in Settings. The permit checker does not soften or hide a limit. The warning goes on the shift log: “Operator tried 55 mg/L (the storm card): warned”.

    “A dose outside the permit cannot be logged without the on-call supervisor. This rule is locked in Settings.”

  6. 06Has this happened before?

    The same storm card, the same river, a few years earlier

    Incident matcher

    Beside the answer, the incident matcher shows a past incident. Raw water rose to 52 NTU. The night operator followed the storm card and raised alum from 20 to 60 mg/L in one step. The pH fell to 6.1 and treated-water aluminum reached 0.24 mg/L. The report gives the root cause. The card was written for alkalinity of about 55 mg/L, and no jar test had been run at storm levels that month.

    “Notified to the regulator · 2.1 ML run to waste · service reservoir flushed”

  7. 0702:44

    Step 1 set and signed, and the senior operator told

    Treatment operator

    The operator sets the pump to 69 L/h, or 28 mg/L. That is step 1 of 2, because SOP §5.3 allows at most 10 mg/L per step. The operator signs the shift-log entry the knowledge keeper drafted with the reason. The agents do not write to the plant, so the operator sets the pump. The night's total change will pass 15 mg/L, so the senior operator is told and acknowledges at 02:45.

    The senior operator, on call: “Good. Watch the pH, not the settled.”

  8. 0803:12

    Withdraw the storm card: a note waiting for the process scientist

    Senior operator, on call

    After the warning, the senior operator phones in a note. The knowledge keeper drafts it in the senior operator's own words, with the evidence. It waits with two more notes for the process scientist. One says filter 4 needs twenty minutes run to waste after a backwash. The other says the river's second flush comes six to eight hours after the first peak. The senior operator retires in 66 days. Of their 38 notes, 24 already appear in answers.

    The note: “Withdraw the storm card. It was right for the old water. Tonight it would have taken us over on aluminum again.”

  9. 0903:59

    The follow-up jar test agrees: 38 mg/L

    Treatment operator

    SOP §6 asks for a follow-up jar test within 2 hours of any change over 10 mg/L. Six jars are set up from the answer, from 30 to 50 mg/L in steps of 4. The operator imports the bench readings from the turbidity meter and pH meter. The lowest settled turbidity is 0.7 NTU, at 38 mg/L. The test is saved as the new reference for river water at 30 to 60 NTU.

    “The answer holds. Lowest settled turbidity at 38 mg/L (0.7 NTU), the dose set at 02:54.”

  10. 10The permit view

    Nine limits, one warning, no breach

    Water quality compliance manager

    The compliance manager owns the permit, version 4. The view lists the nine conditions a dose can move. They are aluminum, turbidity at each filter, outlet pH, free chlorine, contact time, trihalomethanes, iron, manganese and chlorate. Each shows the permit limit, the works target, the 30-day high and tonight's prediction. Tonight there is one warning, at 55 mg/L. There were no breaches in the last 12 months.

    “Permit text is quoted word for word · owner: compliance manager”

Who it’s for

Night operator, senior operator, scientist, compliance and the network crew

A storm night at the works, from the control desk to the compliance office. Here is how each of the five handled it before, and how they handle it now.

Treatment operator
Sets each dose, signs each entry
Before
Alone in the control room from 19:00 to 07:00, unsure whether the storm card's 55 is still right. The SOP is on a shared drive, the jar tests in a spreadsheet and the card on the wall.
Now
Asks in plain words and gets the dose, the pump rate and each line of the working with its source. Can try any other dose against the permit before touching the pump.
Senior operator
On-call supervisor, close to retiring
Before
Takes the 3 a.m. calls after 31 years at the works. Knows how the river behaves in a storm, mostly from memory. Alum does not chase turbidity, and the pH is what to watch.
Now
Has notes recorded in their own words and pinned to the clause they explain. Once approved, they show in answers with their name. Decides any dose outside the permit.
Process scientist
Owns the treatment SOPs and dose curves
Before
Revises the SOPs and signs off dose-curve changes. Meanwhile storm cards and old quick guides live on the plant floor. A rule outside the SOP is not a procedure.
Now
Approves or rejects each expert note with its evidence. Sees the replaced documents still on the floor, and reads each answer rated wrong.
Water quality compliance manager
Owns the permit
Before
Reports breaches to the regulator after the lab sample comes back. Wants to know before the sample does.
Now
Sets the works targets inside the permit. Sees each limit a dose can move, its margin and each warning shown on a shift.
Network technician
Repairs mains and returns them to supply
Before
Repairs mains in the dark. Has to know the flush volume and the field tests before a main goes back into supply.
Now
Gets the mains-repair SOP as numbered steps with the flush volume worked out and the field readings checked against each limit.
The agents

The reader, finder, calculator, checker, matcher and keeper behind each question

Six agents read the SOPs, the permit, the jar tests and the live plant behind each answer. The operator sets each dose, and the supervisor decides anything outside the permit.

Question reader

Reads the operator's question in their own words. Pulls the latest readings from the plant historian: raw turbidity, pH, alkalinity, temperature, flow and the current setting. From these it works out the works, the stage, the chemical and the pump.

  • Read-only on plant data. It never writes to the plant
  • Never guesses a works or a chemical, and asks when two match
Procedure finder

Searches the SOPs, equipment manuals, permits, standards, lab methods, incident reports and approved expert notes. Returns each passage with its document, revision and clause, preferring the current revision.

  • Cites document, revision and clause
  • Quotes permit and safety text word for word and never rewrites it
  • Labels an outdated document, such as an old storm card, as superseded
Dose calculator

Starts from the latest jar test for the river's current turbidity. Applies the SOP correction table. Turns the dose into a pump rate using the chemical strength and the current flow. Works out the alkalinity used and the pH. Splits the change into steps under the step-size rule.

  • Never sends a setpoint to the plant
  • Keeps to the SOP's largest allowed step
  • Shows each input and its source
Permit checker

Predicts aluminum, filtered turbidity, pH, alkalinity, chlorine, contact time and by-products for the proposed dose. Compares each with the permit limit and the works target. Green is inside both, amber is outside a target and red is outside the permit, with the clause.

  • Never softens or hides a limit
  • A red dose cannot be logged without the supervisor
Incident matcher

Finds past water-quality incidents with conditions like tonight's. Shows each beside the answer, with what happened, why and the lesson it left.

  • Always shows the root cause and the status
Knowledge keeper

Drafts the shift-log entry from each answer. Drafts notes in the senior operator's words from recorded sessions and calls. Gathers the plant evidence and proposes SOP changes.

  • The operator signs each entry
  • Never publishes a note or changes an SOP. The process scientist approves each note
On-call supervisor

Decides any dose outside the permit.

Ask in plain words

Dose, procedure and permit questions answered from the works' own files

The assistant answers from the works' SOPs, permit, equipment manuals, jar tests, incident reports and approved expert notes. It cites each one. These answers use the sample data.

Why not the storm card's 55 mg/L?

The water has changed. The storm card was written years ago for raw alkalinity of about 55 mg/L. Since the upland blend it has been 30 to 38, and tonight it is 34. At 55 mg/L, alum uses up 27.5 of it, leaving 6.5. That is below the minimum of 10. The pH falls to about 6.2 and aluminum stays dissolved. The outlet would reach 0.23 mg/L, above the 0.200 in permit condition 4.2. That is what happened in the past incident on file.

Set up tonight's follow-up jar test

It is due within 2 hours of the change over 10 mg/L, so by 04:41. Set six jars around 38 mg/L in steps of 4: 30, 34, 38, 42, 46, 50. Take raw water from the intake tap rather than the inlet channel. Use the lab method's 2 / 15 / 20 minute timing.

Which limits can tonight's dose move?

Nine conditions of the permit are checked on each dose answer. For alum, four of them move. They are aluminum (4.2) and filtered turbidity (4.3), plus two SOP limits that protect them: pH 6.4 to 6.9 and alkalinity of at least 10. At 38 mg/L all are inside. The safe range tonight is 30 to 42 mg/L.

What has the senior operator said about storm nights?

Nine of their 38 notes are about coagulation in storms. Tonight's answer used this one: “step the alum up in tens and watch the coagulation pH, not the settled turbidity”. Two more wait for the process scientist. One is about the river's second flush six to eight hours after the first peak. The other is about withdrawing the old storm card. The senior operator retires in 66 days.

The screens

The dose answer, the permit check, the jar test and the expert notes

From the working solution, on its sample data. Pick one to see it large.

The dose answerLive plant readings, the question, the dose and pump rate with each line sourced, and the permit check beside it.
How the answer was workedThe steps to set, the jar-test curve, the senior operator's approved note, the replaced storm card and the agents' run log.
Try another doseThe storm card's 55 mg/L turns the permit check red. Aluminum breaks permit condition 4.2, and pH and alkalinity fall outside the SOP.
A red dose needs the supervisorThe operator cannot log a dose outside the permit. It goes to the on-call supervisor with the permit check attached.
Step 1 logged and signedThe operator sets the pump and signs the drafted entry, and the on-call supervisor is told.
A procedure answerReturning a repaired main to supply: numbered steps quoted from the SOP, the flush volume worked out and the field readings checked.
The follow-up jar testSix jars around the answer and bench readings imported. The best dose is compared with the one set and saved to the dose curve.
The permit and its limitsEach condition a dose can move, with the permit limit, works target, 30-day high, tonight's prediction and margin.
Procedures and sourcesAn answer can cite 1,204 documents, from SOPs and permits to expert notes and storm cards, each with revision, owner and status.
Has this happened before?Past water-quality incidents with what happened, why, the lesson and the timeline. They show beside answers when conditions match.
The shift logReadings, questions, answers, warnings and setpoint changes in order, with drafted entries waiting for the operator's signature.
Expert notesA retiring senior operator's knowledge, in their own words, pinned to the clause it explains and waiting for the process scientist.
Permit and dose rulesLimits and works targets, what warns and what stops, and the order sources are trusted in.
Governance

Sourced lines, locked permit rules and signed entries for water operators

Each line cites its sourceEach line of an answer cites a document, revision and clause, a jar test, or a plant reading with its time. Open any citation to read the passage it came from.
Permit text quoted word for wordPermit conditions and safety steps are quoted word for word. Procedure steps taken from the SOP are marked as quoted. Replaced documents are labeled superseded wherever they appear.
Agents read the plant and do not write to itLive readings come from the plant historian, read-only. “Agents may write setpoints to the plant” is locked off in Settings. The operator sets each dose.
A red dose needs the supervisorA dose outside a permit limit shows in red with the clause. It cannot be logged without the on-call supervisor, and that rule is locked on. A total change over 15 mg/L in one shift is reported to the supervisor.
Expert notes are drafts until approvedNotes from senior operators keep their author's name and words, and carry their evidence. They reach answers only when the process scientist approves them. A rejection keeps its reason on record.
Each answer on the recordFor each answer, the record keeps the question, the sources and the calculation inputs. It also keeps the warnings shown and who signed. Each signed entry goes on the shift log with its time.
Configuration

Permit limits, step rules and source order for operator knowledge search

The limits each dose is checked against are settings. So are what warns, what stops and the order in which sources are trusted. Each change is saved as a new version.

SettingDefaultChoose from
Permit limits and works targetsPermit limits read from the permit and locked; works targets set inside themAmber from the works target. Red at the permit limit. For pH, amber outside 6.4 to 6.9, red below 6.2 or above 7.1. For alkalinity left, amber below 10, red below 7
A dose outside the permit cannot be logged without the supervisorOnAlways on
Warn when a prediction passes the works targetOnOn · Off
RampAt most 10 mg/L per step, 10 minutes apartOn · Off
Follow-up jar testWithin 2 hours of a change over 10 mg/LOn · Off
Show replaced storm cards in answers, marked supersededOnOn · Off
Agents may write setpoints to the plantOffAlways off. Agents read the plant and never write to it
Sources, in the order they are trustedPermit, SOPs, equipment manuals, standards and lab methods, approved expert notes, incident reports, storm cardsStorm cards never outrank an SOP
Connections

SOPs, the permit, the plant historian, jar tests and the shift log

SOPs and O&M manualstreatment and network SOPs with revision, owner and review date, and equipment manuals with chemical strengths
Permits and standardsthe works' permit conditions, the utility's drinking water quality standard and lab methods
Plant historianlive intake turbidity, pH, alkalinity, temperature, flow, settings and alarms, read-only
Jar testsbench readings from the turbidity and pH meters, and the works' dose curve
Incident reportspast water-quality incidents with timeline, root cause and lesson
Shift log and expert sessionshandovers, readings and signed entries; recorded walk-throughs and calls with senior operators
What it changes

Checked doses and kept storm knowledge for the water operator team

Each figure carries its label: a target the solution is built to, an estimate, a typical published result, or a proven one.

target
0answers
shown outside a permit limit without a warning, the design goal. Each dose is checked
100% of doses
checked against the permit
typical
21%
of water utility staff can retire within 5 years; their storm knowledge stays
target
< 1minute
to a cited dose on the night shift, where a call-out takes 20 minutes
Today20 min call
With the answer< 1 min

“Demo” means seen in the working solution, on its sample works data. “Target” means the design goal, measured in the live solution. “Estimated” means our estimate, here the split of minutes for one dose change on a night shift. “Typical” means published figures, here AWWA 2025, which found 21% of water utility staff can retire within 5 years. The limits come from published rules. Aluminum at 0.2 mg/L is the indicator value in the EU Drinking Water Directive 2020/2184. It is also the top of the US EPA secondary standard range of 0.05 to 0.2 mg/L. The 0.3 NTU filtered turbidity limit is from the US EPA surface water treatment rules. Names on the screens are sample data.

Questions

Water operator knowledge search questions from treatment managers

What is water operator knowledge search?

It is a search tool for treatment operators and network technicians. It answers from the works' own SOPs, equipment manuals, permit, jar tests and incident reports, and each line has a source. A chemical dose comes back as a worked calculation with a permit check beside it. A procedure comes back as numbered steps with the SOP and permit text quoted.

How does the coagulant dose calculation work?

The dose calculator starts from the latest jar test at the river's current turbidity. It applies the SOP's correction table. It turns the dose into a pump rate, using the chemical strength from the equipment manual and the current flow. It then works out the alkalinity used and the predicted pH. In the sample, 35 mg/L at 40 NTU plus 0.6 mg/L per NTU gives 38 mg/L. That is 93 L/h on the pump, set in two steps.

Does it check every dose against the drinking water permit?

Yes. Before an answer is shown, the permit checker predicts each limit the dose can move. In the sample works there are nine. It marks each green, amber or red against the works target and the permit limit, with the clause. The operator can slide to any other dose and see which limit it would break. A dose outside the permit cannot be logged without the on-call supervisor.

How does it keep a retiring operator's knowledge?

The knowledge keeper drafts notes from recorded sessions and calls with senior operators, in their words. Each note is pinned to the SOP clause it explains and backed by plant evidence. The process scientist approves or rejects each note. Approved notes appear in answers with the author's name. Replaced storm cards and quick guides are flagged and can be sent for withdrawal.

Can the agents change setpoints on the plant?

No. The agents read the plant historian read-only and do not write to the control system. That setting is locked off. The operator sets each dose on the pump and signs the shift-log entry the knowledge keeper drafts.

Does it work for network technicians as well as treatment operators?

Yes. A network technician can ask, for example, when a repaired main can go back into supply. They get the mains-repair SOP as numbered steps with the flush volume worked out. The field chlorine and turbidity readings are checked against each limit.

Who decides a dose outside the permit?

The on-call supervisor. The operator sets each dose and signs each entry. The on-call supervisor decides anything outside the permit and is told of large changes. The process scientist owns the SOPs and approves expert notes. The compliance manager owns the permit limits and works targets. Each answer, warning and signature is kept on the record.

Which documents does a treatment works load first?

Your SOPs, equipment manuals, permit, jar-test records and incident reports. The Agentic Solution Engine builds and deploys it from those requirements and documents. It goes live once each quality gate has passed. We will walk you through it on your own works and a past storm night first.

Search your own SOPs
and permit on a past storm night.

We'll run Water Operator Knowledge Search on your own SOPs, permit and a past storm night.