- Before
- Alone in the control room from 19:00 to 07:00, unsure whether the storm card's 55 is still right. The SOP is on a shared drive, the jar tests in a spreadsheet and the card on the wall.
- Now
- Asks in plain words and gets the dose, the pump rate and each line of the working with its source. Can try any other dose against the permit before touching the pump.
Water operator knowledge search on a storm night, as the river rises
A treatment works on a river supplies 38 ML/d, or 38 million liters a day. It is the night shift. One treatment operator is alone in the control room, and the senior operator is on call. Here is what happens, screen by screen, in the working solution.
A worked example on sample data. Names, IDs and figures on the screens and in this section come from the demo.
- 0119:00 to 02:30
A dry-weather handover, then the river rises
Treatment operatorThe day operator hands over at 19:00. The weather is dry, alum is at 18 mg/L, all 6 filters run, and a storm is due after 23:00. The shift log fills from the plant historian and the weather feed. Intake turbidity reads 6 NTU at 22:00 and 19 at 00:40. The settled water alarm sounds at 2.5 NTU at 01:50. By 02:30 the intake reads 45 NTU. Alum is still on the dry-weather setting, 18 mg/L and 44 L/h on the pump.
Handover: “Dry weather. Alum 18 mg/L, all 6 filters in service, filter 4 due a wash. Storm forecast after 23:00.”
- 0202:41
“Coagulant dose at 45 NTU?”, answered as a worked dose
Treatment operatorThe operator asks in their own words. A live, read-only strip from the plant historian sits above the answer. The intake reads 45 NTU, raw pH 7.3 and alkalinity 34 mg/L. Water is at 9.2 °C, flow is 38.0 ML/d and settled water is 2.9 NTU. The answer is to raise alum to 38 mg/L, or 93 L/h on the pump. Each line of the working has a source. The latest jar test found 35 mg/L best at 40 NTU. SOP Table 2 adds 0.6 mg/L per NTU above that. Then 38 g/m³ × 1,583 m³/h ÷ 645 g/L gives 93.3 L/h.
“Raise alum to 38 mg/L · Liquid aluminum sulfate on the dosing pump, for raw water at 45 NTU and 38.0 ML/d”
- 037.8 seconds
The SOP, the permit, the jar test and the plant, read in order
The six agentsThe run log shows each step. The question reader took the works, the stage and the chemical from the question and the live readings. The procedure finder found the coagulation SOP, revision 9, §5.3, §5.4, §5.6 and Table 2. It also found the equipment manual §4.2 and flagged the storm card as replaced. The dose calculator split the change into two steps under the step-size rule. The permit checker checked 9 limits, all inside. The senior operator's approved note sits beside the jar-test curve.
The senior operator's approved note: “Above 40 NTU, step the alum up in tens and watch the coagulation pH, not the settled turbidity.”
- 04Try the storm card
The storm card says 55. The permit check turns red
Treatment operatorAt 38 mg/L every meter is green. Treated-water aluminum is 0.060 mg/L, against the permit's 0.200 and a works target of 0.100. Filtered turbidity is 0.12 NTU against 0.30. The pH is 6.7, inside the SOP range of 6.4 to 6.9, with 15 mg/L of alkalinity left. The operator slides the dose to the storm card's 55. Aluminum goes to 0.230 mg/L and pH to 6.2. Alkalinity left drops to 6.5, below the minimum of 10.
“Breaks permit condition 4.2: aluminum 0.230 mg/L. Also outside the SOP: alkalinity 6.5 mg/L.”
- 05Log 55 instead?
A dose outside the permit needs the supervisor
Permit checkerIf the operator tries to log the red dose, the solution stops the entry. It offers to send the dose to the on-call senior operator to decide, with the permit check attached. This rule is locked on in Settings. The permit checker does not soften or hide a limit. The warning goes on the shift log: “Operator tried 55 mg/L (the storm card): warned”.
“A dose outside the permit cannot be logged without the on-call supervisor. This rule is locked in Settings.”
- 06Has this happened before?
The same storm card, the same river, a few years earlier
Incident matcherBeside the answer, the incident matcher shows a past incident. Raw water rose to 52 NTU. The night operator followed the storm card and raised alum from 20 to 60 mg/L in one step. The pH fell to 6.1 and treated-water aluminum reached 0.24 mg/L. The report gives the root cause. The card was written for alkalinity of about 55 mg/L, and no jar test had been run at storm levels that month.
“Notified to the regulator · 2.1 ML run to waste · service reservoir flushed”
- 0702:44
Step 1 set and signed, and the senior operator told
Treatment operatorThe operator sets the pump to 69 L/h, or 28 mg/L. That is step 1 of 2, because SOP §5.3 allows at most 10 mg/L per step. The operator signs the shift-log entry the knowledge keeper drafted with the reason. The agents do not write to the plant, so the operator sets the pump. The night's total change will pass 15 mg/L, so the senior operator is told and acknowledges at 02:45.
The senior operator, on call: “Good. Watch the pH, not the settled.”
- 0803:12
Withdraw the storm card: a note waiting for the process scientist
Senior operator, on callAfter the warning, the senior operator phones in a note. The knowledge keeper drafts it in the senior operator's own words, with the evidence. It waits with two more notes for the process scientist. One says filter 4 needs twenty minutes run to waste after a backwash. The other says the river's second flush comes six to eight hours after the first peak. The senior operator retires in 66 days. Of their 38 notes, 24 already appear in answers.
The note: “Withdraw the storm card. It was right for the old water. Tonight it would have taken us over on aluminum again.”
- 0903:59
The follow-up jar test agrees: 38 mg/L
Treatment operatorSOP §6 asks for a follow-up jar test within 2 hours of any change over 10 mg/L. Six jars are set up from the answer, from 30 to 50 mg/L in steps of 4. The operator imports the bench readings from the turbidity meter and pH meter. The lowest settled turbidity is 0.7 NTU, at 38 mg/L. The test is saved as the new reference for river water at 30 to 60 NTU.
“The answer holds. Lowest settled turbidity at 38 mg/L (0.7 NTU), the dose set at 02:54.”
- 10The permit view
Nine limits, one warning, no breach
Water quality compliance managerThe compliance manager owns the permit, version 4. The view lists the nine conditions a dose can move. They are aluminum, turbidity at each filter, outlet pH, free chlorine, contact time, trihalomethanes, iron, manganese and chlorate. Each shows the permit limit, the works target, the 30-day high and tonight's prediction. Tonight there is one warning, at 55 mg/L. There were no breaches in the last 12 months.
“Permit text is quoted word for word · owner: compliance manager”