- Before
- Publishes the day-ahead forecast at 10:00 and runs the power model again when the weather changes. Can give the 3 pm peak, but cannot say what it does to the reservoirs.
- Now
- Forecasts power and water together on each new bulletin. Sees the reservoir path beside the peak. Signs each version, with its meaning recorded.
A heatwave bulletin at 09:40, a signed forecast and an approved fix by 10:34
A utility supplies both electricity and drinking water. On a summer Wednesday, the lead load forecaster has already published Thursday's day-ahead forecast. Then the weather service raises Thursday's maximum. Here is what happens next, screen by screen, in the working solution.
A worked example on sample data. Names, IDs and figures on the screens and in this section come from the demo.
- 0109:40
A new bulletin puts Thursday 2.9 °C hotter at 15:00
Lead load forecasterThe 06:00 run, published at 06:41, had Thursday's peak under the all-time record. It had the north reservoirs at 47 % at midnight, with no conflict. Then the 09:40 bulletin from the weather service puts Thursday 2.9 °C hotter at 15:00 than the 05:30 bulletin did. It also forecasts haze from 09:00 to 17:00. The heatwave band is drawn across all four lanes of the chart before anything is run again.
“Heatwave in the 09:40 bulletin · not yet in the forecast”
- 0210:11
Power and water re-forecast on the same weather
Six agentsThe lead forecaster presses Re-forecast both. The weather reader takes the bulletin and the 51-member ensemble, a set of 51 slightly different weather runs. The calendar keeper confirms a normal working day, with schools still on their summer holiday. Both forecasters then run on that one weather and calendar. The run log fills in the side panel, step by step, with a time on each.
Power demand forecaster: “Thursday 15:00: up 0.54 GW, with its P10 to P90 band, above the all-time record”
- 0310:12
The 15:00 peak, explained driver by driver
Power demand forecasterForecast v2 is set against v1, and each change is tied to its driver. Temperature, up 2.9 °C, adds 0.41 GW. Humidity adds 0.06, haze on rooftop solar 0.05 and building heat carried over from Wednesday 0.02. EV charging and the calendar were checked and did not change. Beside the bars sit the bulletin text the weather reader used, each line cited, and the weather by zone that both forecasts used.
“The temperature effect is strongest from 13:00 to 17:00, when air conditioning is at full load.”
- 0410:12
A dispatch rule drains the north reservoirs
Power and water balance checkerAt the new peak, the reserve margin is 9.2 %, under the 10 % trigger. So the curtailment rule cuts four RO trains at one water plant, 61 MW of load, from 13:00 to 19:00. Water demand rises through the day, most of it after 17:00, when people come home. The north reservoirs feed three zones. At 10:00 they read 57.7 % on SCADA, the control room's live readings. By midnight they fall to 34 %.
“The north reservoirs fall under 40 % at 19:00 and reach 34 % at midnight. A power-only forecast would not have shown this.”
- 05Three fixes
Each option priced in storage, reserve, cost and CO₂
Power and water balance checkerOption A keeps the water plant at full and runs a peaker gas turbine. It gives 45 % at midnight for $78,400 and 218 t CO₂. Option B pre-fills the north reservoirs through the north main from a second reservoir, 22:00 tonight to 20:00 Thursday. It gives 46 % for $5,700 and 45 t CO₂, and the RO cut still frees 61 MW for the peak. That is $72,700 and 173 t of CO₂ less than option A for the day. Option C asks the north zones to save 5 % from noon. It gives 37 % and five hours under the minimum. Each option shows its storage path and who acts.
Option B is recommended. The balance checker only proposes options. It does not change a plant schedule or send a dispatch instruction.
- 0610:21
Forecast v2 signed, with the meaning of the signature
Lead load forecasterThe signature box shows what is being published. That is the new 15:00 peak with its P10 to P90 band and the revised water forecast. Both were made from the 09:40 bulletin, and they replace v1. The lead forecaster chooses the meaning, “Approved for dispatch and production planning”, and signs with a password. On publish, v2 goes to unit commitment, fuel nominations, the water control room and energy trading.
Only the lead forecaster publishes. The forecasters draft.
- 0710:34
The shift manager approves option B
Dispatch shift managerThe lead forecaster sends option B to the shift manager with a note. It reads: “Heatwave Thursday: north reservoirs short by midnight on the current plan.” The shift manager approves at 10:34. The plan goes to the power station and the water control room, which opens the north main valve at 22:00. The water production planner is told. Option A would have had the fuel scheduler booking gas for the peaker.
“Option B approved by the shift manager at 10:34 · north reservoirs 46 % at midnight”
- 08Back on the forecast
The north reservoirs hold at 46 % overnight
Lead load forecasterThe Forecast screen now shows v2, published at 10:21. The north main transfer is drawn on the coupling strip, from Wednesday 22:00 to Thursday 20:00. The storage lane stays above the 40 % line. The same strip shows the link working the other way too. Four steam units at the power station are held at 1.42 GW overnight, because the water units they feed need steam.
“North main opens at 22:00 tonight. The four RO trains still give 61 MW to the peak.”
- 09On the record
v1 is replaced and kept as it was
Forecast versionsEach version is kept, with what it was made from, its peak and water total, its status and who signed it. Thursday's v1 shows Replaced 10:21. Tuesday's v2 already carries its actual peak and its MAPE, 1.7 %. The v1 against v2 chart shows the change by hour. The largest is +0.54 GW at 15:00.
“Each version is kept · a version is published only with the lead forecaster's signature”
- 1001:00 each night
Scored by hour and by heat day, with drift found
Accuracy trackerThe accuracy tracker scores each published version against actuals. Over 90 days, the joint forecast's day-ahead MAPE is 2.4 %, against 3.6 % for the previous model. The error is highest at the afternoon peak and again at 21:00, when EV charging and evening cooling overlap. On the 14 heat days of the summer, its day-ahead power error was 2.9 %. The previous model, run in parallel, scored 5.1 %. The tracker found one zone's water forecast running 2.6 % low each day since 2,140 new connections came on. A retrain is ready.
The accuracy tracker retrains a model only with approval. This retrain waits for the head of system planning.