On older plates the last number is the biggest impeller the casing takes. The sample caught 7 trimmed pumps read that way.
09:10 to 09:31: the pump class, filled, sent back and filled again
A master data team fills the equipment register ahead of a system move, one class at a time. On this morning the pumps went through, and came back.
demoSample data: the plants, the people and the register.
- 01First thing
86 classes as tanks, and the whole register sits at 49.1%
Master data leadThe tank farm shows 286,400 equipment records in 86 classes at three sites. A tank’s level is the share of its required attributes that are filled, against a dotted target of 85%. The agent suggests pumps next: 6,240 records at 37% with 15,998 pages on file. Isolation valves sit lower, but few of their pages exist.
- 0209:10
Pumps at 37.0%, and one maker spelled 14 ways
Master data leadThe pump tank holds 149,760 required attributes: 24 for each pump. 55,411 are in the register with no page behind them yet, and 94,349 are blank. Impeller diameter sits at 20%, maximum impeller at 11%, seal drawing at 7%. Under the tank, one pump maker appears 14 ways. The lead starts the batch, and nothing reaches the register until a sample passes.
- 0309:13
15,998 pages read, 76,378 values proposed, 17,971 left blank
Master data leadAgents work through drawings, datasheets, manuals, nameplate photos and repair records, and 14 spellings become one name on 1,383 records. Of the 55,411 values already held, 41,204 match a page, 12,795 have no page and 1,412 disagree and go to the steward. The tank climbs to 88.0%, hatched, because it is proposed and nothing is written yet.
- 0409:16
400 values to read, and the proposal hidden until each one is read
Discipline data reviewerThe rotating equipment reviewer gets the batch and a sample: 240 ordinary values with 2 wrong allowed, 120 safety values with none, and 40 blanks. Each value is read on its own page first, and the proposal shows only after. The top line says what a pass means: if 1 in 45 ordinary values were wrong, this sample would catch it 9 times in 10.
- 0509:17
The plate says 11.75 inches; the agent read 13 from the model code
Discipline data reviewerOn a lean amine pump the nameplate carries its impeller on its own line: 11.75. The proposal is 13.00 in, taken from the last number of the model code. On older plates from this maker that number is the largest impeller the casing takes, and this one was trimmed. The reviewer marks the proposal wrong and picks the reason: read from the wrong place.
- 0609:19
Seven wrong sizes, and the whole pump batch goes back
Discipline data reviewerThe agent points to the other values in the sample read by the same rule. The reviewer reads each plate: 7 are wrong, and 2 are right because those impellers are full size. That is over the limit, so the batch goes back with its reason. Nothing is written, and the tank falls back to 37.0%.
- 0709:25
The impeller rule is fixed by maker, then tested on the nine plates
Equipment class stewardThe lead proposes a new rule: take the size from an impeller line or a later shop record, use the model code only where that maker puts the fitted size in it, and otherwise leave it blank. The steward tests it before countersigning: on the 9 plates, 7 sizes correct to the impeller line and 2 stay, and 40 more plates show no new wrong value.
- 0809:31
The rerun lands lower, at 87.6%, with 574 sizes left blank
Master data leadThe rerun reads 1,698 impeller sizes again. 1,124 now come from a real impeller line or a shop record, and 866 of those changed. 574 have only a model code behind them, so they stay blank with that reason. The tank stops at 87.6%, below the first run, and the screen says why. A fresh draw of 400 values is ready for the reviewer.
- 0909:31
One of the 574: a crude pump with no impeller on its plate
Master data leadThe lead opens one of them, an atmospheric bottoms pump. Its datasheet states no fitted impeller, and the model code gives only the casing maximum of 15.00 in. So impeller diameter stays blank, with the reason only a model code gives a size, until the pump is next opened.