- Before
- Starts at 07:00 with the overnight queue and works it all day. Sorts by code and joins data by hand, looking for the one alarm in eighteen thousand that is on fire.
- Now
- Opens the stream and the 23 incidents it folded into, each with its alarms, its likely cause and the team that acts.
One Tuesday, 18,214 meter alarms become 23 actions
A large utility reads its electricity and water meters over AMI, its smart meter network. On an ordinary Tuesday, the shift lead runs the alarm queue in the metering center. Here is the day, screen by screen, in the working solution.
A worked example on sample data. Names, IDs and figures on the screens and in this section come from the demo.
- 0114:20
The whole day's alarms on one screen, and what they folded into
AMI operations analyst, shift leadEach alarm since midnight is one tick, in a row per family. The families are power fail, power restored, voltage, tamper and cover, temperature, register and firmware, battery, comms and water flow. Under the stream, a summary shows what was taken out. That is 4,860 duplicates, 2,408 blips under 3 seconds, 2,512 alarms from planned work and 1,522 information-only alarms. The other 6,912 were kept and folded into 23 incidents, each a group of alarms with one cause. The incidents sit in seven team lanes, with safety alarms at the top of each lane.
“18,214 alarms → 23 need action”
- 02Replay 06:12
A wall of last gasps folds into one outage
AMI operations analystAt 06:12:41 the meters on one feeder, a line out of a substation, start sending last gasp. The last one arrives at 06:13:19. The analyst replays the window, and 1,860 last gasps fold into one incident. It is a feeder outage at one primary substation, covering 1,860 meters. The analyst sees why the incident exists before opening it.
“1 incident · Feeder outage · 1,860 meters”
- 0306:14:21
An outage ticket proposed before the first customer calls
Stream reader, Noise filter, Event correlator, RouterThe stream reader attached each meter's feeder, spur and transformer. The noise filter checked its 5 rules. No power came back inside 3 seconds, and the morning's planned outage is on a different feeder. So nothing was taken out. Next, the correlator placed the 1,860 meters on one feeder, three spurs and 12 transformers. The router then proposed a top-priority (P1) outage ticket for the control room. At 06:16 the control engineer confirmed it.
Router: “1 min 40 s after the first last gasp. First customer call 06:19”
- 0406:58
448 meters still off, all beyond one fuse
Event correlator · distribution control engineerAt 06:57 a switch closes to restore two of the three spurs, and 1,412 meters come back. The 448 that fail the restore ping all sit beyond one fuse on the third spur, on three transformers. The likely cause is a blown fuse, at 91%. Less likely is a recloser locked out, at 7%. A recloser is a switch that trips and retries by itself. Three customers on one of those transformers use life-support equipment at home.
Proposed: “Send a crew to the fuse”, for the control engineer to confirm · “Call the 3 life-support customers”, for customer care
- 0514:11
A hot socket reaches field service in two minutes
Router · field service dispatcherA meter at one home reports socket temperature 78 °C at 13:31, 84 °C at 13:52 and 92 °C at 14:11. The limit is 75 °C. Voltage imbalance at the socket is rising alongside. The electric oven and heat pump share the circuit, with a load of 41 A. The likely cause is a loose jaw in the meter socket overheating under load, at 88%. The router sends it to field service as P1, on a 5-minute clock. At 14:13 the dispatcher confirms the safety visit.
Socket temperature high is a safety code. It is not taken out or folded away.
- 06Make safe
A remote disconnect, proposed for the supervisor to decide
Field service dispatcherUntil the socket is replaced, a remote disconnect is an option. The proposal goes to the field service supervisor with the alarm history attached. The solution has already checked the account. There is no life-support or medical flag, and no weather protection in force today. The supervisor decides.
“Agents never disconnect, reconnect or dispatch.”
- 0702:41
A cover-open flag, with the consumption behind it
Revenue protection scorer · revenue protection investigatorAt another home, the meter reports a cover open at 02:14, then six magnetic-field alarms up to 02:40. The scorer adds what makes it a lead. Use fell 61% from the night of an earlier cover-open, while the neighbors on either side stayed flat. There is no open work order, and the last visit was an earlier meter test. The score is 0.91, against a case threshold of 0.70. The investigator took it at 08:12.
“A tamper score is not proof. This solution does not contact the customer. The revenue protection investigator decides whether it becomes a case.”
- 08All day
Each alarm taken out names its rule and who approved it
Noise filter · Rule tuner · head of meteringOf the day's alarms, 11,302 needed no action. Each was taken out by one of five rules, with its approver and date. One rule comes from the control engineer's switching order for the planned outage, added at 08:40. The rule tuner proposes a new rule for reverse-energy blips on solar homes. There were 4,118 such alarms in 90 days, and none led to an action. The rule would not hide any home that has no registered solar. It runs only if the head of metering approves it.
Always kept: load-side voltage while disconnected · socket temperature high · backflow
- 09Hand-offs
Each team on its own clock, each decision with a name
Seven teams, each with the person on shiftSeven teams each get their incidents, their clock and the person on shift. They are the control room, field service, revenue protection, meter shop, water network, AMI network and customer care. The hand-off log shows who confirmed what. For the hot socket, the dispatcher confirmed the safety visit. The water network team sent an inspector to a nursing home for a backflow. The dispatcher also booked a two-person visit to a home where the house side of a disconnected meter is live.
“Today, safety: 3 of 3 · hot socket 2 min · live load side 3 min · backflow 3 min”
- 1030 days
The month, in the numbers the head of metering reports
Head of meteringIn 30 days, 577,227 alarms became 687 incidents. Approved rules took out 62% of today's alarms. The 76 safety alarms reached a person in a median of 2 min 40 s, against a 5-minute clock. None went over it. Outages were confirmed from the meters in a median 1 min 52 s, and 204 field visits were avoided.
“Safety alarms to a person · 2 min 40 s · median, 30 days · clock 5 min · none missed”