- Starts at 06:30 with the overnight read report and the head-end alarm list. That is 1,287 alarms in one morning, when what is needed is the six things that are actually broken.
- Now
- Opens the network map on six incidents, each with one device, its evidence and its cut-off. Confirms the cause before anything goes to the field.
One night on the network, with a dark router and one fix
A large utility reads its smart meters and water endpoints over a radio network. On a Monday at 21:40, a pole-top router on a residential road loses its power supply. Here is what happens next, screen by screen, in the working solution.
A worked example on sample data. Names, IDs and figures on the screens and in this section come from the demo.
- 01Tue 06:40
The shift opens on a map of the radio network
AMI operations analystThe analyst owns read rates for a block of billing cycles. The map draws this part of the network as it really routes. It shows one collector at the local substation, 13 routers, and each meter and water endpoint as a dot colored by read success. Read success over 24 hours is 99.62%, against a 99.5% target. The overnight alarms read 1,287 → 6 incidents. The next cut-off at risk is Thursday's.
“412 without a read behind the router · 41 re-routed”
- 02Replay the night
The night, hop by hop
AMI operations analystThe scrubber replays Monday 21:00 to Tuesday 06:40. The router reports AC power lost at 21:40 and battery low at 01:58. Its last heartbeat comes at 02:14. From then on, amber spreads out through the meters behind it. By 03:10, 41 have turned blue as they find a new route through a nearby router. Beside the map, the Thursday cut-off forecast falls from 99.8% to 96.8%, below the 99.5% line.
“If nobody acts, 435 meters on this route have no read at cut-off: 318 electricity and 94 water behind the router, and 23 single meters”
- 0306:27-06:31
One device behind 412 silent meters
Root-cause finderThe root-cause finder walks the routing tree. In all, 453 meters share the router as their last parent. They went silent from 02:11 to 02:14, inside 3 minutes of its last heartbeat. Its parent and its neighbor are healthy. The remote fixer pinged it three times at 06:28, with no answer. The outage system shows its feeder energized. Field history shows the battery past its rated 6 years. The root cause is named at 06:31, at 94% confidence.
“Feeder energized, no outage at the pole, so the fault is the router's own power tap”
- 04The device
Everything known about the failing router, on one page
Root-cause finderIt is a pole-top router, fed from its feeder through a pole power tap. Its event timeline runs from the lost AC power to the outage check. Of the meters behind it, 150 are direct, 200 two hops out and 103 three hops out. It has three radio neighbors. Its parent is at −78 dBm and healthy. A second router at −84 dBm took 41 meters. A third at −93 dBm is too weak to re-route to. The last inspection noted the power tap corroded.
Ping, on-demand reads and a work order are one click from the device.
- 05The other five
Six incidents, each with one device behind it
Alarm grouper and Remote fixerThe alarm grouper put the 1,287 alarms into groups by shared parent device, time and event pattern. Of these, 838 are the router's. A collector at a depot drops its cellular link from 01:00 to 05:00, but its reads are buffered. That incident is with the telecom engineer. On 286 meters in one area, a firmware version lets the clock drift past 90 seconds. The remote fixer sent a time sync, and 279 recovered. Another 133 water endpoints from an older batch have low batteries. The read watcher found 1,749 single meters with missed reads, and 1,186 answered an on-demand read at 06:05.
“A root cause below 80% confidence is shown as unexplained”
- 06The week ahead
Eight cut-offs, forecast before the bill run
Cut-off forecaster · for the billing operations leadThe table lists the next eight route cut-offs. Each shows the read rate the cut-off forecaster expects at 23:59 on the day, and the incident that changes it. Thursday's route reads 96.80%, with 435 estimated bills. That drops to 23 if the router is fixed by 15:00 today. The water route with the low batteries reads 98.70%, with 155 bills. That drops to 22 once the batteries are replaced next Monday. The assumptions are printed under the table.
“Re-registered meters back-fill their stored reads within 2 hours; buffered collectors hold 72 hours; scattered single meters at each route's 30-day average.”
- 0706:40
The analyst confirms the root cause
AMI operations analystThe analyst reads the evidence on the rail and confirms. The root cause turns green, and the work order drafter starts writing the order. Nothing goes to the field yet. The order still needs the field meter supervisor's approval, and the 412 orders for single meters are held.
“Root cause confirmed · the Work order drafter is writing the order”
- 08If fixed by 15:00
What the fix time does to Thursday's bills
Cut-off forecasterThe analyst sets “If the router is fixed by” to 15:00 today. Meters re-register and back-fill their stored reads within 2 hours. So Thursday's cut-off goes back to 99.8%, with 23 estimated bills. A fix by Wednesday 12:00 would leave 29 meters unread. A fix by Thursday 18:00 would leave 141. With no fix, 435 stay unread.
“Fixed by 15:00 today · 99.8% at cut-off, 23 estimated bills”
- 09Approved
One order to one pole, in place of 412 meter visits
Field meter supervisorThe order is to replace the power supply and battery on the router at the pole. One crew goes today from 13:00 to 15:00, with the router's power supply unit and a 12 V battery pack. The root-cause finder's evidence goes with it. The supervisor approves, and it goes to the crew's tablets. Today's orders avoid 507 meter visits, and 1,476 this month.
“412 ‘meter not responding’ orders, one per address, are held. They close when the router is back and each meter reads.”
- 10Drafted 06:35
The daily network health report, each number linked
Report writer · for the analystThe report writer drafted it at 06:35 from the night's reads, incidents and forecasts. It covers read success, the six incidents and their actions, and what it means for billing and for the field. When the analyst signs, it goes to billing operations, telecom, field meter services and the AMI operations team.
“Draft · not sent. The Report writer never sends without your signature.”