- Before
- Owns the inventory, closes each quarter and answers the assurer — from spreadsheets, re-keyed invoices and cylinder logs.
- Now
- Opens the inventory as one chart, posts what the agents have read and checked, and releases evidence packs. “I want every tonne to have a parent — a page someone can open.”
One SF6 top-up, from a paper log to the disclosure total
Lumina Utilities runs electricity and water. On Tuesday 13 October 2026, three days after its Q3 close, the year-to-date inventory stands at 2,528,142.6 tCO₂e. Overnight, a substation supervisor's handwritten cylinder log has been scanned. Here is what happens next, screen by screen, in the working solution.
- 01Morning
The inventory opens as one live chart
Hannah Okafor · Sustainability reporting leadHannah owns the inventory. Her home screen is the inventory itself: 13 sources on the left flow into Scope 1 (1,347,822.6 tCO₂e), Scope 2 (296,660.0, location-based) and Scope 3 (883,660.0), and on to gross emissions of 2,528,142.6 for 1 Jan – 13 Oct 2026. Beside it, two records read this morning wait for her to post, and the totals feed the IFRS S2, GRI 305-2 and CDP 7.8 lines.
“Every tonne from its source, through its scope, to the disclosure total · Q3 closed 10 Oct”
- 02One switch
How good is the data behind each flow?
Hannah Okafor · Sustainability reporting leadColour by data quality recolours every flow: measured by a meter or stack monitor, calculated from activity records with a factor, or estimated from spend, population or averages. 55.8 % of the total is measured, 35.8 % calculated and 8.4 % estimated — the weak flows are plain at a glance: capital goods, freight, wastewater treatment and most of purchased goods.
Assurers sample hardest where data is estimated.
- 0312 Oct, 15:40
A density alarm, a top-up, a paper log
Ravi Menon · Substation maintenance supervisorAt Harrowgate 132 kV, breaker CB-204 in bay 4 raises a stage 1 density alarm. Ravi tops it up from cylinder SF-88213 — 41.362 kg before, 41.183 kg after, gas pressure 5.9 to 6.4 bar g at 20 °C — and writes it on log SF6-LOG-2026-0146. The scan reaches Source records at 09:12 next morning, beside 1,486 records read this quarter.
“Nothing reaches the inventory without its record”
- 0409:12
The handwriting read, the breaker and cylinder matched
Source reader and SF6 balance keeperThe Source reader reads 11 handwritten fields with 0.99 confidence and checks the 3 in 41.183 against the scale photo. The SF6 balance keeper matches CB-204 in the asset register — a GIS breaker installed 2011, nameplate charge 18.6 kg — and cylinder SF-88213, issued by Halden Gases on 2 Sep at 41.940 kg. A 0.5 bar rise on 18.6 kg means 0.17–0.19 kg expected; 0.179 kg is consistent.
Source reader: never guesses a value it cannot read — reads below 0.95 confidence go to a person.
- 0509:13
4.2 tCO₂e — and the third top-up this year
Factor matcher and Quality checkerThe Factor matcher applies GWP 23,500 (IPCC AR5): 0.179 kg is 4,206.5 kgCO₂e, or 4.2 tCO₂e. The Quality checker finds CB-204 was also topped up on 14 Mar (0.164 kg) and 22 Jun (0.171 kg): 0.514 kg this year, 12.1 tCO₂e, 2.8 % of its charge. That crosses Lumina's leak rule, so it drafts leak repair WO-77815: a gas-camera leak search at the planned outage on 27 Oct, and a new bay 4 density monitor seal if the leak is confirmed.
Leak rule: “3 top-ups in 12 months or 2% of charge a year”
- 0609:31 · posted
Hannah sends the repair and posts the tonnes
Hannah Okafor · Sustainability reporting leadHannah sends WO-77815 to Tomás Reyes for approval, then posts the log. The SF6 flow pulses with “+4.2 tCO₂e · SF6 · Harrowgate CB-204”: SF6 rises from 1,842.6 to 1,846.8, Scope 1 to 1,347,826.8 and gross emissions to 2,528,146.8 tCO₂e. No agent can post; the record waited for her.
Checks: “Harrowgate CB-204: third top-up this year, 2.8% of charge. Repair WO-77815 sent to Tomás Reyes.”
- 07Any tonne
The lineage, one record at a time
Daniel Brandt · Group financial controllerOpen the activity data and every record has its chain: source record SF6-LOG-2026-0146 → 0.179 kg read from Ravi Menon's handwriting → GWP 23,500 from factor set 2025 → 4.2 tCO₂e, checked by the Quality checker → IFRS S2 29(a)(i) and GRI 305-1. Below it, every cylinder log this year, each with its activity, factor and status.
“Treat it like the ledger: no posting without a document.”
- 08Mass balance
SF6 kept by mass balance, breaker by breaker
Tomás Reyes · Environmental compliance engineerThe SF6 screen shows the four terms for 38 substations and 612 breakers: a 21.400 kg decrease in storage, plus 260.000 kg bought, minus 120.000 kg returned to the supplier, minus 82.811 kg charged into new equipment — 78.589 kg emitted, × 23,500 = 1,846.8 tCO₂e. Breakers are ranked by gas lost against the 2 % line: CB-204 at the top, then Brenmoor GIS bay 2 and Ostler Road CB-11 being watched.
“Breakers by gas lost this year · rule: repair at 3 top-ups in 12 months or 2% of charge a year” — CB-204: “Repair sent · WO-77815”
- 09Draft, year to date
The IFRS S2, GRI 305 and CDP drafts follow the inventory
Disclosure drafterEvery figure in the drafts is live from the inventory and opens the flow behind it. The IFRS S2 paragraph 29 table now reads 1,347,826.8 for gross Scope 1, and the draft text says every SF6 top-up is traced to a signed cylinder log. The sign-off chain runs Hannah (prepared), Tomás (reviewed), Mei-Lin Chow (signed) and Daniel Brandt (co-signed); the panel lists what changed since the last review.
“The Disclosure drafter writes; it never publishes or signs. Changes after review reopen the chain.”
- 10The assurer asks
The cylinder log is one click away
Evidence packer · for Grace Liu, Kestrel & RoweKestrel & Rowe's sample request AS-14, due 20 Oct, asks for every CB-204 top-up this year, the mass balance and the GWP. The Evidence packer has six items ready: logs 0039, 0091 and 0146, the four-term mass balance, the factor set 2025 approval and the postings. The pack could not leave until log 0146 was posted; now Hannah releases it.
“Please provide the cylinder logs for every top-up of CB-204 at Harrowgate this year, the SF6 mass balance and the GWP used.” — Grace Liu