Custody transfer measurement at a plant tailgate, from drawing to notice
A sales gas station at a plant tailgate read its heating value high for weeks, and the month's statement has not gone out yet. Here is the morning that prices the error and puts it in front of the buyer, on the working screens.
demoThe station, both companies, the contract wording and every figure here are sample data.
- 0109:40
Three duty runs, a check meter, and a chromatograph 0.6% high
Measurement analystThe station opens as it is built: filter separator, three ultrasonic duty runs, a check meter on the header, the flow computer, the chromatograph with its calibration standard and heater. Each part carries its last check. Under the drawing, the heating value strip shows this station stepping up while the station downstream on the same gas stays flat.
- 0209:40
A cabinet heater tripped before a 19 °F night, with no alarm
Measurement analystOpening the analyzer cabinet heater shows the station event log: the heater fault, a 19 °F night, and the automatic calibration that ran the next morning. The agents offer this as the likely cause, for a person to confirm: the calibration gas went short of heavy components in the cold. The expired certificate the technician found moved no reading.
- 0309:40
The lab read 1,036.7, and nobody set it beside the chromatograph
Measurement analystThe spot sample point is marked never compared. Its lab report, emailed to the measurement mailbox, read 1,036.7 Btu per cubic foot while the chromatograph was reporting 1,043.0. It was filed. A person found the fault later, and the first agent cycle priced it. From here on, each report is compared when it arrives.
- 0409:43
17 gas days, known definitely, so the fallback clause does not apply
Measurement analystAcross 31 daily calibration reports, the heavy-component factors stepped down at one calibration and came back when the standard was replaced; the meters' speed of sound and the downstream station agree on the same days. The tolerance clause allows 0.5% and the error is 0.60%, so the correction clause applies to the known period.
- 0509:43
Each gas day is a row, and the rows add to 44,611 MMBtu
Measurement analystRead volume, read and true heating value, and the overstatement, day by day. At the sample contract price of $3.00 that is $133,833 off a bill not yet sent. The screen also shows the fallback, half the days since the last check: 14 days, $110,319. Nothing posts from here, and the statement stays held.
- 0609:49
Hexanes plus fell 79.0% at one calibration, and no alarm sounded
Measurement leadThe analyst sends the working to the lead, and nothing reaches the buyer. Before she can sign she must open four records herself. The first is the calibration report: the response factor changes against the day before, and an alarm window of plus or minus 100% that let them through. That window is a finding of its own.
- 0710:01
Four records opened, then her signature on $133,833
Measurement leadShe opens the standard's certificate, the correction clause and the day-by-day working, and her own opening is what counts. Then she signs. The chain across the top moves to countersigned, with the contracts manager, because the amount is above $50,000. A send-back would clear her openings and need a reason.
- 0810:04
The contracts manager reads the correction clause in its own words
Gas contracts managerClause 9.4 is quoted, never paraphrased: correct to zero error for the period known definitely, otherwise half the time since the last check. The contracts manager opens it and the working before the countersign button turns on. Unclear wording comes to this desk, never to an agent.
- 0910:13
Notice sent with the working, and the statement still held
Gas contracts managerCountersigned at 10:10, the notice of correction goes to the buyer with the working attached, inside the contract's notice clock. Sent notices are frozen by version. The buyer's measurement representative, who witnessed the tests on the old cylinder, now has it. The lead decides and posts only after that reply.