- Before
- Finds out after the fact that a control was out of contract or a unit had changed, once the numbers are already in the warehouse.
- Now
- Sees each file stop at the station where it fails, with the evidence beside it, and decides each stop on the conveyor.
CRO data integration for one plasma export whose concentration unit changed
A weekday morning, 09:40. The bioanalysis CRO drops a plasma concentration workbook on SFTP: LC-MS/MS concentrations of one compound in mouse plasma after an IV and an oral dose, 9 samples, under section 2 of its statement of work. Here is what happens next, screen by screen, in the working solution.
A worked example on sample data. Names, IDs and figures on the screens and in this section come from the demo.
- 0109:40
Six CROs on one intake conveyor
Study monitorThe study monitor follows the studies the sponsor runs at six CROs. The intake conveyor has a lane for each CRO and four stations: Received, Mapped, QC-checked, Loaded. This week: 38 deliverables, 30 loaded, 1 ready to load, 4 stopped for a decision, 1 waiting on the CRO, 2 on the way in. The bioanalysis CRO's new file sits at Received.
Drift watch: “Before a single value is mapped, each file is compared with its CRO's last accepted layout: headers, column order, units and value ranges.”
- 02One click
Stopped at Mapped: the concentration unit changed
Template drift checkerThe deliverable classifier matches the workbook to its CRO, study and contract section. The template drift checker compares its header with that CRO's template v3, last used on the previous study, and finds four changes. Sample became Sample ID and Flag became BLQ, matched by meaning. Route and Time (h) swapped places, matched by name. Column E went from “Conc (ng/mL)” to “Conc (µg/mL)”, and that stops the file.
The template drift checker does not accept a unit change on its own.
- 03What would have loaded
1.284 ng/mL, or 1,284 ng/mL
Study monitorThe diff shows what an import would have done: the IV sample at 0.25 h reads 1.284 and would load as 1.284 ng/mL instead of 1,284 ng/mL, and an oral sample would load as 0.451 instead of 451. The CRO's last three runs at 0.25 h read 1,190–1,410 ng/mL, so the values agree with the new header. The study monitor chooses “Convert × 1,000 and save template v4”. The rule is applied, template v4 is saved and the data steward who owns the template is informed.
The other choices on the same screen: “Query the CRO” or “Hold the file”.
- 04QC-checked
Two samples reported as 0, below the 1.0 ng/mL limit
Study-spec checkerThe rest of the intake runs. The result extractor reads 9 samples, IV and oral, each with its cell in column E; the unit and identity normaliser converts the values to ng/mL and matches the compound through the shipped manifest. The study-spec checker stops at two samples taken at 24 h, which the export writes as 0 with flag BLQ. Loading 0 would pull exposure down.
Suggested: “Load both as "below LLOQ (1.0 ng/mL)", not as zero.”
- 0509:49
All checks passed or decided
Study monitorThe study monitor loads both as below LLOQ. The inspector now reads: “Every check passed or is decided. 9 values mapped to house units, each citing its cell or page.” Both decisions sit on the file with the monitor's name: the schema drift converted × 1,000 with template v4 saved, and the two samples loaded as below LLOQ.
- 0609:51 · Loaded
Nine values in the research data warehouse
Warehouse loaderOne click on “Load 9 values”. The warehouse loader checks the records against house schema v4, writes them with house units, qualifiers and flags, holds back no values, links each to its page or cell and refreshes the SAR view for the program. The deliverable moves to Loaded, eleven minutes after it arrived.
The warehouse loader loads only when each exception on the deliverable is decided.
- 07Any value
A value opens to its source cell
DMPK scientistIn the review, the workbook sits beside the record grid. Click the compound, IV at 0.25 h, and a line runs to cell E5: as reported 1.284 µg/mL, in house units 1,284 ng/mL, confidence 97, “µg/mL converted to ng/mL (× 1,000) by the rule approved today”. The two 24 h samples read <LLOQ (1.0 ng/mL), not zero.
- 08Same morning
The change becomes template v4
Research data stewardOn File templates, the CRO's plasma concentration export is now v4: column E reads µg/mL → ng/mL. The quarter's drift log gains its newest row: this study, unit changed, converted × 1,000, template v4, decided by the study monitor. Earlier rows show how harmless changes were handled: a sheet renamed at one CRO was matched by content, and a column moved at another was matched by name.
Renamed or moved columns are matched above 95% confidence; a unit change in a header always stops the file.
- 09Next on the list
The CRO marked it Pass. The contract does not.
Study-spec checkerThe ADME CRO's metabolic stability study, 96 values from human and mouse liver microsomes on day 8 of 10, is read with a page or cell for each value, and 46 are converted to house units. On page 6 the verapamil control on MLM plate 2 ran at 17.9 min. The CRO's SOP accepts 3–20 min and calls it Pass; section 4.2 of the contract allows 3–15 min, and the report notes a second freeze–thaw of the microsome lot on that plate.
The study-spec checker does not mark a failed control as passed: the contract range wins over the CRO's SOP.
- 10On the exceptions board
Hold, flag, record, or query the CRO
Study monitor and data stewardEach exception arrives with its evidence and a proposed decision. For the plate 2 control: hold the 22 MLM values and ask the CRO to repeat the plate with a fresh microsome lot. For a compound whose replicates show a CV of 31% against the contracted 20%: load with a “high variability” flag. For one that precipitated at 1 µM and was not incubated: record as “not tested, solubility”. Another CRO reports a compound ID that is not on the shipped manifest, so the data steward decides whether it is a listed compound with two digits swapped on the tube label.
“The agents propose. A named person decides.”