- Before
- Owns 11 works and reads every consultant report for them, then types the grades into the EAM by hand. “I paid for 148 pages and I get to read them properly once.”
- Now
- Opens the report beside its findings, every row tied to its sentence, and decides only the findings the agents question — with the 2021 sentence and the work orders beside each one.
One five-yearly survey, from 148 pages to the EAM
Lumina Utilities runs Kestrel Bay Water Treatment Works. Arden Hale Consulting has finished its five-yearly condition assessment, KBW-CA-2026 Rev 0: 148 pages, surveyed 1–18 September 2026, issued 2 October, received 12 October. Here is what happens next, screen by screen, in the working solution.
- 01Tue 13 Oct
The report opens beside its findings table
Hannah Okafor · Asset engineerHannah owns the treatment works in the south region and reads every consultant report for them. The review screen shows the report itself on the left, page by page, and the 63 assets in scope on the right, each with its 2021 grade from KBW-CA-2021. The 2026 column still reads “not read”.
“Not read yet. Six agents will read all 148 pages, match every asset to the register, check each reading against its limit and compare every grade with the 2021 survey and the work history. You decide on anything they question.”
- 02One click
Six agents read the survey, step by step
Six agentsShe clicks Read the report. The report reader takes in 5 sections, 31 tables, 108 photographs and 9 test certificates in Appendix C. The asset matcher finds 63 of 64 assets in the register. The findings extractor pulls 142 findings and 38 readings, the limits checker tests the readings against 10 limits, and the history checker compares every grade with 2021.
Asset matcher: “Matched 63 of 64 assets to the register · MCC4 is not in the register · P-03 serial differs.”
- 034 min 12 s later
Twelve findings need her; the rest are ready
Hannah Okafor · Asset engineerThe screen opens on Needs you: 12 of 142 findings. Raw water pump P-03 shows Serial differs, MCC4 Not in register, and seven rows are Out of limit, including CB-03 contact resistance at 142 µΩ, transformer T1 oil at 38 kV and acetylene at 4 ppm, raw water pump P-02 at a polarisation index of 1.4 and the DN600 rising main wall at 6.1 mm.
“Read by six agents in 4 min 12 s · 142 findings and 38 readings from 148 pages · 7 out of limit · 6 grades questioned against the 2021 survey · 12 need you”
- 04Any row
Every reading, tied to its sentence and its limit
Findings extractor and Limits checkerClicking transformer T1's insulating oil row scrolls the report to section 4.10 on page 32 and highlights the sentence: breakdown voltage 38 kV, certificate LAB-26-0912. The row shows the reading against the IEC 60422 limit of ≥ 40 kV for equipment below 72.5 kV, and the recommended action.
Limits checker: “Filter and dry the oil; resample after treatment.”
- 05The question
The roof rose from 2 to 4 with no repair on record
History checkerArden Hale graded the filter building roof covering 4, good. In 2021 Pellow & Marsh Engineers graded it 2, with blistering, splits and water getting into the filter gallery. The work history shows only gutter clearing in March 2023 and a temporary patch in January 2024; roof replacement CP-2023-118 is deferred, not started. Photograph 5.4 shows a single-ply membrane, but the filter building has built-up felt.
History checker: “The chemical building roof was relaid in single-ply in June 2024 (work order 4502216). The surveyor may have graded the wrong roof.”
- 06Decided
Hannah keeps grade 2 and asks Arden Hale
Hannah Okafor · Asset engineerThree sources sit side by side — this report's sentence on page 52, the 2021 sentence on page 28, and the work orders — and the asset history draws the grade over 2016, 2021 and 2026 with the questioned rise dashed. Hannah chooses Keep grade 2 and ask Arden Hale. Accepting grade 4 would have needed a written reason, shown to the condition assessment lead with the summary.
“Kept grade 2 · question sent to Arden Hale · 11 still need you” — answer due in 10 working days under framework FW-0417.
- 07Since 2021
Every grade that moved, and why
History checkerChanges since 2021 sets the two surveys against each other for the 63 assets in both: 49 held their grade, 9 got worse, 5 improved. Six grades are questioned, among them backwash pump P-07, which rose 2 → 4 while its vibration stayed the same (6.9 mm/s in 2021, 6.8 now), and CB-07, graded 4 while its trip time is 71 ms. Seven element grades that improved are explained by completed work, such as the CB-05 mechanism overhaul in July 2022.
“Improved, with the work that explains it · 7 — accepted by the History checker”
- 08Seven defects
Every reading past its limit becomes a defect
Hannah Okafor · Asset engineerReadings shows the 38 readings against their limits, each with its standard, source page and recommended action: replace the L2 vacuum interrupter on CB-03 at the next outage; restrict CB-07 to manual switching until it trips within 60 ms; rewind or replace the P-02 motor and run P-01, P-03 and P-04 as duty. Hannah clicks Raise defects for all 7, and DN-8841208 to DN-8841319 are drafted for the maintenance planner.
“7 defects drafted for the maintenance planner · 4 findings still need you”
- 09Released
Wen releases the update; the health index recalculates tonight
Wen Li · Asset data stewardThe EAM update file holds a condition update or reading for every finding, each with its source page. Hannah sends 138 ready updates to Wen Li; 4 stay held until they are decided. Wen releases them, and the register correction for P-03 (serial KX-22-80417, Kestner KS-450, installed 2024) and the new asset record for MCC4 are waiting for her.
“Wen Li released 138 updates · Kestrel Bay WTW health index recalculates tonight”
- 10For capital planning
A one-page summary, signed twice
Graham Pell · Condition assessment leadThe update writer drafts the summary from the findings and Hannah's decisions, every line linked to its page. It tells capital planning to keep filter building roof replacement CP-2023-118 in the 2027 plan, and says the DN600 rising main at 6.1 mm against 7.0 mm supports bringing its renewal forward. Hannah signs and sends it to Graham Pell, who signs and sends it to Imogen Shaw.
In one line: “The filter building roof is not improved: it stays at grade 2 until the consultant explains a grade the work history does not support.”