- Before
- Owns 214 controls and four audits this season, each with its own spreadsheet: one password control, tested four times by four auditors who ask for it four ways.
- Now
- Opens each control at the center of its web, reads both texts for each link and confirms the ones waiting in the morning.
A password control, four audit programs and one test for the season
A Tuesday at the sample utility. The audit season is close: ISO 27001 surveillance next month, the IEC 62443 assessment of the water SCADA the month after, the water cyber attestation due at year end, and the NERC CIP audit on site early in the new year. Here is what happens to one control, screen by screen, in the working solution.
A worked example on sample data. Names, IDs and figures on the screens and in this section come from the demo.
- 01Morning
The crosswalk opens on the password control
Head of cyber GRCThe head of GRC owns the utility's library of 214 controls. Overnight, from 02:10 to 02:31, the agents checked the library against 762 requirements in five frameworks. The password and shared-account management control, owned by the identity and access lead, sits at the center of the web, linked to 7 requirements in 4 frameworks: three in NERC CIP, two in IEC 62443, one each in NIST CSF and ISO 27001. One link is waiting for a decision.
“tested once · was 4” · Owner: identity and access lead · quarterly
- 0202:22
One link re-proposed, with both texts side by side
Crosswalk mapperThe framework reader found that the latest ISO 27001 Statement of Applicability reworded three controls, so the crosswalk mapper proposed the ISO 27001 A.5.17 link again. The head of GRC clicks the node and reads the requirement and the utility's control side by side, with the mapper's reason and the evidence against the requirement: the vault workflow's issue, reset and rotation procedure, on page 5.
Why they match, full: “The Annex A control asks for a management process for authentication information; the control’s vault workflow is that process.”
- 03One click
The link is confirmed by a person
Head of cyber GRCNothing counts toward coverage until a person confirms it. The head of GRC confirms the link, and it is recorded under their name; it can still be challenged later. The other links waiting across the library stay in the queue.
“ISO 27001 A.5.17 confirmed · 26 links still waiting across the library”
- 04Trace the evidence
One report meets all seven requirements
Evidence matcherThe head of GRC presses Trace the evidence. The password vault's policy and rotation report for the last quarter runs out along each link, and each requirement's own parameter is ticked as it lands: length 14 against CIP's 8 with three character types, the oldest password 11 months against 15, lockout after 5 tries with an alert, 23 default accounts changed, 1,284 accounts managed.
“One evidence item, 7 requirements, 4 frameworks · collected once”
- 05Page by page
Each passage tied to the requirement it satisfies
Evidence matcherIn the evidence view, the report's passages carry margin notes. The 37 local accounts on one relay model at several substations support at most 6 characters; they are set to the device maximum, which CIP-007-6 R5.5 allows without a technical feasibility exception. Of 1,906 evidence items this cycle, 683 satisfy requirements in two or more frameworks, so they are collected once.
CIP-007-6 R5.5: “or the maximum the Cyber Asset supports”, met at the device maximum
- 06The whole library
Eleven gaps, before the auditor finds them
Gap finderThe coverage heatmap shows each family of each framework, sized by its requirements and colored by how well the utility's controls cover it: 751 of 762 requirements fully covered, 7 partial and 4 with no control. IEC 62443 FR 1 shows 42 of 44, with SR 1.11 partial and SR 1.13 without a control. The overlap grid shows why testing once works: 179 controls serve both NERC CIP and ISO 27001.
“751 of 762 requirements fully covered · 7 partial · 4 no control”
- 07Before the IEC 62443 assessment
A compensating control, accepted with an end date
Chief information security officerOne gap: the 14 HMI workstations in the water treatment control room alert the SOC after 5 failed logins but do not lock out, because a locked HMI mid-shift would leave the operator blind to the filters and dosing. The water OT security engineer, who owns the control, proposes a compensating control: alert on 5 failures in 10 minutes, the SOC calls the shift supervisor within 15 minutes, and lockout comes with the planned HMI upgrade. The CISO accepts it until the upgrade date.
“Accepted until the HMI upgrade · signed by the CISO · on the audit trail”
- 0802:31
One test per control, with the strictest sample
Test plannerThe test planner merges each program's test of the same control: 214 tests this season, not 612, feeding 426 audit samples across five programs, with testing in the weeks before the first audit. The password control's test takes a sample of 60 accounts for the last quarter and feeds NERC CIP, IEC 62443, NIST CSF and ISO 27001.
“398 duplicate tests avoided · $1.1M a year, estimated · 398 × 22 h × $125”
- 09Sent to sign
The plan goes to internal audit
Head of cyber GRCThe head of GRC sends the season's plan to the internal audit manager with a note: samples are set to the strictest auditor for each control, and the password control uses 60 accounts for CIP-007 R5 and the 62443 assessment.
“Signed plans cannot be changed, only revised.”
- 10Signed
One signed plan for the season
Internal audit manager, IT/OTThe internal audit manager signs plan v1. Testing runs in the weeks before the first audit, and each control is tested once for each program it feeds: the ISO 27001 surveillance audit, the IEC 62443 assessment, the water cyber attestation, the NERC CIP audit and the CSF self-assessment.
“The internal audit manager signed the plan · 214 tests, testing starts on the set date”