Run the evaluations, decide positions and sign each trend statement
- Poolability, model and Q1E worked in view
- Their own draft challenged before use
- Excursions read tray by tray
Stability study management software that draws each chamber shelf by shelf, reads every approved result onto its tray, applies ICH Q1E in the open and sends clients a co-signed trend statement.
Follow one 18-month result to a signed statement ↓The stability program lives in a LIMS schedule, a chamber spreadsheet, a regression in a spreadsheet and a letter written in Word. When a long-term result lands, the stability lead copies it into the regression, pools the batches because it is quicker, draws a straight line and writes to the client.
Nobody tested whether the batches could be pooled, the degradant curves upward, and the line runs past what the guideline allows. The client files on it, and the regulator cuts it later. Meanwhile a humidity excursion is judged for the whole chamber, so either every tray is questioned or the one capsule tray on the top shelf passes on the average.
Built forQC stability leadsStability coordinatorsQA stability reviewersHeads of QC
When pooling goes untested and the line runs past the Q1E limit, the shelf life a client files promises more than the data hold.
Four records, joined by hand
Built-in controls
Clients file the shelf life their data support, with the evaluation shown so their regulator can follow it.
The QC stability lead reads a client's 18-month result for three tablet batches at 30 °C / 75% RH, while the client hopes to file a longer shelf life.
demoThe CDMO, its chambers, clients, people, products, batches and results are sample data.
Facilities confirm what happened in a chamber; the client owns the shelf-life proposal.
Run the evaluations, decide positions and sign each trend statement
Pull each time point in its window and load the chambers
Give the second signature on statements and excursion assessments
Answer for the stability program to clients and inspectors
Each agent reads the stability records without changing them and hands a named person the next step.
Keeps each pull inside its window, proposes the year's commitment batches and finds chamber space.
Reads each LIMS-approved result and places it on its tray and time point.
Checks each result against its trend, chooses the model, tests poolability, computes each batch's bound and the Q1E ceiling.
Reads probes and the mapping study to find which trays an excursion touched, on which shelf and for how long.
Reads the draft as the client's regulator would and raises each weak point.
Drafts the trend statement with a source on each sentence and prepares its transmittal.
Slopes differed at p = 0.002 against Q1E's 0.25, so each batch was fitted on its own; the shortest meets 0.50% at month 30.6.
Residuals ran high at months 0 and 18 in all three batches; on a straight line one batch's bound would have reached month 47.
A lyophilized product's water at month 9 read 1.5%, above the range its earlier points predicted and still inside NMT 2.0%; its next statement waits for the laboratory check.
Of 25 trays in the chamber during a humidity excursion, 5 in moisture-permeable packs or with capsules went to a person.
demoSample data, from the working solution.
Around the statement: the excursion, the week's results, the pulls, the year's commitments and the rules in force.
demoSample data, from the working solution.
Stability study management software runs a stability program: studies, chambers, pulls, results, trends and statements. Here it draws each chamber tray by tray, reads every approved result as it lands, applies ICH Q1E with the working shown, and drafts a statement two people sign before the client receives it.
With no significant change at accelerated and a statistical analysis, the shelf life may reach up to twice the period of long-term data, but no more than twelve months beyond it. Where batches differ, the shortest one governs.
Only when an analysis of covariance at the significance level Q1E names shows slopes and intercepts do not differ. Otherwise each batch is fitted on its own with the pooled error, and the shortest bound decides.
Each new result is compared with the range its own study's earlier points predict, using the interval in the site's procedure. A result outside it goes to a laboratory check even while it is still inside the limit.
No. The statement says what the data support; the client owns the shelf-life proposal and its filing. The QC stability lead and the QA stability reviewer sign before anything is sent.
Tray by tray, from the probe on each shelf, the time above tolerance and how well the pack keeps moisture out. Trays in sensitive packs go to the stability lead, and a facilities engineer confirms the cause before QA signs.
It cannot be logged as on time. The pull schedule shows each tray's window and its place in the chamber, and once the window has passed the pull stays locked until someone raises a deviation. The pull scheduler never logs a pull itself.
New client products join shared lines sooner, with every residue limit still defensible.
1-min demoQuality Risk Management (ICH Q9)Risk files that move with the evidence, so no score rests on a control that stopped working.
1-min demoGMP Inspection ReadinessThe record gap is found by your own back room, disclosed and logged, before an investigator reads the page.
1-min demoSend a stability study's results and protocol, and we will test pooling, apply Q1E and draft the statement for your review.