WorkflowBilling, Credit & Collections

Rate Code Validation

Rate code validation that checks each account nightly and finds each wrong tariff with its clause, its proof and the refund or back-bill worked out

See one case, screen by screen ↓
Watch with transcript →

Built forRates analystsRates and tariff managersKey account managersBilling analysts

The Problem Today

When a property changes use, nobody tells billing, so the wrong tariff runs for years until a complaint finds it.

$63M
refunded with interest for misclassified homes, one US utility published

Four records nobody compares

  • Licenses
  • Tenancies
  • Title deeds
  • Meter data
  • The bill still computesBilling checks that the sum adds up, and stops there
  • Back-bills past the limitUnder-billing found too late can no longer be billed

The Solution

  1. The tariff book as rulesEach rule on use, load, household and riders tied to its clause
  2. Accounts checked nightlyLicenses, tenancies, deeds and recent hourly use checked together
  3. Months rebilled on the right tariffEach month on the wrong tariff priced again, with tax
  4. Cleared, then signedThe analyst clears it, and the manager signs large refunds and back-bills

Built-in controls

  • No account moved on one signal alone
  • Refund and back-bill limits held both ways
  • Key account managers see a change first

What You Get

More tariff errors are caught by the utility itself, before a regulator orders refunds with interest.

  • Businesses on home tariffs foundSeen in the meter's load shape, confirmed by a license
  • The biggest cause, countedAccounts where occupancy changed and the tariff stayed
  • Under-billing recovered tooBack-bills raised before they are time-barred
In short

What is Rate Code Validation?

Rate code validation software checks that each utility account is on the tariff, or rate code, it qualifies for. When it is not, the software works out the refund or back-bill. Rate Code Validation checks each account each night against the eligibility rules in the tariff book. A rates analyst then clears each account it flags.

How to choose AI solutions for utilities →

Updated

The problem

An account can stay on the wrong tariff for years, because the bill still adds up

A utility bills each account on a tariff, the price plan it qualifies for. The rate code on the account says which tariff applies. When the way a property is used changes, its tariff should change too. A house run as a nursery may become a family home, or a ground-floor unit may open as a grocery. A warehouse may raise its connected load, the power it can draw. A title deed may change hands, or rooftop solar may be connected. Often nobody tells billing.

The billing system's checks do not catch it. Before each invoice goes out, they check that the bill adds up. They do not check that the account still belongs on its tariff. So the bill still computes, and no warning fires. Rate audits check the record, and the record looks right too. Checking by hand does not reach far. With the sample utility's 1,184,400 accounts, checking 50 accounts a week covers about 0.2% of them in a year. So a wrong code comes to light years later, through a complaint, an internal audit sample or a regulator's order. By then the refund is large. The back-bill, the charge for past months the customer underpaid, is past the legal time limit. Under-billing past that limit is revenue lost for good. Over-charging harms the customer and exposes the utility to the regulator.

typical$63Mand more in refunds with interest for misclassified homes at one US utility, approved by the regulator in 2026
typical43,000homesor so in multifamily buildings, billed on the single-family rate class. That is about 10% of that utility's multifamily customers
typical$1.78Mover-billed to its own city by a municipal utility, on mis-set accounts over eight years
Where the days go when one wrong tariff is correctedestimated
By hand28 days
With the solution2.6 days
  • Getting the account onto a list to check, from a monthly extract or the nightly check15 → 0.1 d
  • Pulling the record, licenses, tenancies, deeds and meter reads3 → 0.2 d
  • Rebilling each month on both tariffs, with VAT and the limits3 → 0.2 d
  • Manager review and signature3 → 1.1 d
  • Raising the rebill in billing2 → 0.9 d
  • Writing the customer letter2 → 0.1 d

Our estimate for one account on the wrong tariff, in working days, by hand and with the solution. The figures with the solution follow the medians on the Results screen. The median is 2.4 days from a red cell to a corrected bill.

How it works

Nightly rate code validation, tariff book to signed correction

What comes in
Every account, every night5 sources · tariff book, billing, licenses and leases, hourly reads, premise register
Agents at work
Tariff book readerrules + clauses
Then
Account profilerrecord · load
Document checkerlicense · lease · deed
Usage shape reader90 days hourly
Then
Rebill calculatorrefund · back-bill
Then
Customer letter writercustomer's language
A person decides
Rates analystclears each red cell
What comes out
Account on the right tariff
Refund or back-bill
Signed record
One case, step by step

A nursery became a family home, but stayed on the commercial tariff for 26 months

The sample utility bills 1,184,400 accounts from the current edition of its tariff book. One night the check runs from 01:00 to 02:47. Here is what happens next, screen by screen, in the working solution.

A worked example on sample data. Names, IDs and figures on the screens and in this section come from the demo.

  1. 0101:00-02:47

    Each account against each rule, overnight

    Six agents · the nightly check

    The tariff book reader turns the current edition into six eligibility rules tied to 41 clauses. Next, the account profiler reads 1,184,400 accounts with their tariff history and load. Alongside it, the document checker matches 642,180 licenses, tenancies, deeds and certificates. The usage shape reader scores 1,092,600 meters on 90 days of hourly reads. By 02:31 the rebill calculator has rebilled, month by month, each account that breaks a rule. By 02:44 the letter writer has drafted 1,100 notices.

    “1,312 break a rule · 214 worth over $1,000 come first”

  2. 02Morning

    A grocery on a home tariff, seen in its load shape

    Rates analyst

    The analyst's tariff check lists accounts down the side and the six rules across the top. The rules are premise use, connected load, usage shape, household status, riders and tariff code. Each usage-shape cell draws the meter's 24 hours against what its tariff expects. A ground-floor unit in an apartment building is billed R1 Residential. But its load is flat from 07:00 to 23:00 each day, which matches the shop template with a score of 0.88. A business license for a grocery has been active at the premise for 19 months.

    The fix: R1 → C1 from the license date · 19 months wrong, back-bill held to the 12-month limit · $5,502.45 incl. VAT

  3. 03One click

    A family home on the commercial tariff for 26 months

    Rates analyst

    The first red cell on the list is a house billed C1 Commercial. The premise-use cell reads “License canceled · tenancy residential”. The panel beside it quotes the clause. It draws the home's usage shape against the daytime office shape that C1 expects. It also shows the fix, already worked out. The house moves to R1 Residential from the month the family moved in, with 26 months rebilled.

    Clause 4.2: “C1 applies to premises used for trade, with an active business license or a commercial lease registered at the premise.”

  4. 04The account

    The nursery closed, and billing was not told

    Document checker and Account profiler

    The account shows the tariff history. First it was on C1 for a home nursery under a business license. Then it stayed on C1 for a family home that should be on R1. The license was canceled, and a residential lease for the family starts the next month. Each record opens from the evidence list. These are the license register, the lease records, the premise register and the hourly meter reads.

    Premise register: “C1 Commercial since the nursery opened · not changed at the move-in”

  5. 05The proof and the money

    A home’s evenings, and each month rebilled

    Usage shape reader and Rebill calculator

    Ninety days of hourly reads show a home. Use is lowest from 08:00 to 15:00 and peaks from 19:00 to 23:00. Weekend daytime use is 24% above weekdays. The house template scores 0.91, while the daytime office template that C1 expects scores 0.22. The rebill calculator prices the same kWh on R1 for each of the 26 months. That is 70,035 kWh, billed at $25,032.25 on C1 against $17,470.38 on R1, before VAT.

    Refund to the customer: $7,940.00 incl. VAT · 26 months, each month shown

  6. 06The letter

    The refund notice, drafted for the customer

    Customer letter writer

    The letter says what was wrong, the new tariff, the months and the amount. The utility has corrected the tariff and will refund $7,940.00, including VAT, as a credit on the next bill. A table shows each month. The letter apologizes for the utility's error and says the customer does not need to do anything. The analyst approves the wording, and the letter waits for the signature.

    “Drafted by the Customer letter writer · sent after the rates and tariffs manager signs”

  7. 07Cleared and signed

    The analyst clears the cell, and the manager signs the refund

    Rates and tariffs manager

    The analyst clears the cell. This refund is over $5,000, so it goes to the rates and tariffs manager. The manager signs each back-bill and each refund above that line. The sign-off shows the steps in order. Agents proposed with the evidence, the analyst cleared and the manager signed. Next the billing analyst raises the rebill in billing, and the letter goes out.

    “Rates and tariffs manager signed the $7,940.00 refund”

  8. 08A key account

    A cold store owed a refund, and a call before the letter

    Key account manager

    A warehouse in an industrial area is billed C1 Commercial. A load upgrade raised its connected load, the power the site can draw, from 380 to 1,250 kVA. A demand meter was fitted, but no tariff change was raised. Clause 3.1 puts sites of 400 kVA and above on I1 Industrial. Rebilled over 16 months with the demand charge, the cold store operator is owed $105,352.80. Accounts of 400 kVA or more go to the key account manager as well as the rates and tariffs manager.

    Run log: “Key account · key account manager to call before the letter”

  9. 09Not moved

    One signal is not enough

    Usage shape reader

    A townhouse shows more daytime use in recent months. It scores 0.71 against the office template, below the 0.80 the settings require. The document checker finds no business license and no commercial lease at the premise. The cell stays amber and the account stays on R1. It will be looked at again in 90 days.

    “The usage shape alone does not change a tariff. A license, tenancy or record must agree.”

  10. 1014 weeks live

    Money put right both ways, inside the limit

    Rates and tariffs manager

    Since go-live, the Results screen shows $3.92M refunded to 1,507 over-charged customers before they had to complain. It shows $1.77M back-billed to 979 accounts inside the 12-month limit, with installments. In all, 2,486 accounts were corrected and signed, and no back-bill went over the limit. The biggest cause was occupancy that changed while the tariff did not, on 945 accounts.

    “Median 2.4 days from a red cell to a corrected bill. Before, a wrong tariff was found when the customer complained or an audit sample reached it.”

Who it’s for

The four roles who fix a wrong rate code

The same wrong tariff, worked by the four roles who fix it, first by hand and then with the agents.

Rates analyst
Clears cells, releases refunds up to $5,000
Before
Works a list of suspect accounts from a monthly extract, 40 to 60 checks a week by hand. Can check the record, but cannot see how the place is really used.
Now
Opens a grid of each account that broke a rule last night, red first. Each cell shows its clause, its documents, the meter's shape and the money already worked out.
Rates and tariffs manager
Owns the tariff book, signs back-bills
Before
Owns the tariff book and signs each back-bill and each refund over $5,000. Needs the clause, the proof and the months in front of them first.
Now
Signs from one list of refunds and back-bills, each with both tariffs month by month and the limit already applied. Publishes rule changes as a new version.
Key account manager
Reviews accounts of 400 kVA and above
Before
Looks after 38 large industrial accounts. Hears about tariff errors from the customer's auditor, when the call should come from the utility first.
Now
Sees each correction on an account of 400 kVA or more before the letter goes, with the load change, the clause and the refund.
Billing analyst
Raises rebills, sends the letters
Before
Raises each rebill in billing and sends the letters, and needs the corrected months rather than a spreadsheet.
Now
Gets the signed rebill month by month, with kWh, both prices and the difference with VAT, and a letter already drafted.
The agents

Tariff book reader, document checker, usage shape reader and the rest

Six agents read the tariff book, the account, its documents and the meter's hourly shape, and rebill each affected month. The rates analyst clears each red cell.

Tariff book reader

Reads the tariff book and its amendments into eligibility rules, each tied to its clause. The rules cover premise use, connected load band, household status, riders and whether a code is in force. It also names the code that replaces each retired one.

  • Never changes a tariff or a price
  • Each rule cites its clause
  • Shows what an amendment changes before anything is published
Account profiler

Pulls each account's premise type, connected load, household status, riders and dated tariff history. It reads them from billing, the premise register and the connections system.

  • Read only
  • Never merges or edits an account
Document checker

Looks up each business license, lease, title deed and solar connection certificate registered at the premise number. It gives each one's status, its dates and the field that matters.

  • The premise number must match
  • Never accepts an expired document as current
Usage shape reader

Averages 90 days of hourly reads by day of week and hour. It scores the shape against templates for a house, apartment, shop, office, cold store, school and farm. It gives the best match and the match for the tariff billed.

  • Never moves an account on its shape alone. A document or record must agree
  • A match counts as a signal only at 0.80 or above
Rebill calculator

Prices the same kWh and demand on the right tariff for each month on the wrong one, with VAT. Over-charges are refunded for the whole period on record, up to 84 months. Under-charges are back-billed for no more than 12.

  • Never sends a rebill before sign-off
  • Back-bills held to the limit
  • Shows both prices for each month
Customer letter writer

Drafts a short, plain notice that says what was wrong, the new tariff, the months and the amount. It offers installments on a back-bill and apologizes when the error was the utility's.

  • No back-bill letter before the manager signs
  • Never names another customer
Rates analyst

Clears the cell; the manager signs.

Ask in plain words

Questions about wrong tariffs, answered from the records

Ask about an account, a rule, a refund or a back-bill, or say what to change. Each answer points to its records.

Why is this house on the commercial tariff?

Because nobody changed it when the nursery closed. The house was licensed as a home nursery until the license was canceled. Since the next month, a family has lived there on a residential tenancy. The meter shows a home, with an evening peak and busier weekends. Clause 4.2 puts it on R1. Rebilled over 26 months, the utility owes $7,940.00.

Which shops are billed as homes?

There are 183 accounts on R1 or R2 with a shop or office shape above 0.80 and a business license at the premise. The largest is a ground-floor grocery, flat from 07:00 to 23:00 each day and licensed for 19 months. Its back-bill is $5,502.45, held to 12 months.

How much do we owe in refunds from last night?

Last night's check found 788 accounts owed a refund, totaling $2.31M. It found 524 under-billed, worth $1.07M within the limit. On today's list the largest refund is the cold store, at $105,352.80. It is a key account, so its key account manager calls first.

Show the accounts still on retired codes

There are 212 accounts still on a code retired at the start of the year. The new code has the same price, so they move to it without a rebill. A primary school is on today's list. Clear its cell to recode it to G1. The other 211 can be recoded together from the Tariff book.

The screens

The tariff check matrix, a red cell, the rebill and the sign-off

From the working solution, on its sample data. Pick one to see it large.

The tariff checkEach account that broke a rule last night against the six eligibility rules, red first. Each red cell shows its refund or back-bill, with today's tally and last night's run.
A shop on a home tariffThe grocery's flat load from 07:00 to 23:00 against what R1 expects, its grocery license, and the back-bill held to the 12-month limit.
A red cell, openedThe house's premise-use cell beside its evidence. It shows the clause, the home's shape against what C1 expects, and the refund already worked out.
The accountThe house's change from C1 to R1, its tariff history, the meter's 90 days against the templates, the rules it breaks and the evidence.
Rebilled month by monthThe same kWh priced on both tariffs for each of the 26 months, with the refund including VAT, beside the sign-off steps.
The customer letterThe refund notice to the customer, sent only after the manager signs.
Cleared and signedAgents proposed, the analyst cleared, the manager signed, billing raises the rebill and the letter goes out.
A key accountA cold store's connected load raised to 1,250 kVA. The key account manager reviews its move to the industrial tariff and its refund.
One signal onlyA daytime shape below the confidence line and no license at the premise. The account is not moved and is looked at again.
Usage shapesEach account placed by its daytime and evening share and colored by its tariff. Homes billed as shops sit in the wrong cloud.
Refunds and back-billsCorrections waiting for the manager or ready to release, with the change, the months and who cleared each one.
ResultsMoney refunded and back-billed by week, why accounts were on the wrong tariff, and the time from a red cell to a corrected bill.
Tariff rulesThe back-bill limit, refund lookback, sign-off line, nightly schedule and how strict the checks are.
Governance

Two signals, cited clauses and signed refunds in rate code validation

Each red cell cites its clause and its proofEach broken rule shows the tariff book clause, the record and the document behind it. That may be the license, the tenancy, the deed, the load upgrade or the meter reads. Each one opens to the field that matters.
Two signals before an account movesThe usage shape alone does not change a tariff. A license, tenancy or record must agree, and this rule is locked on. With one signal the cell stays amber, and the account is looked at again after 90 days.
The analyst clears, and the manager signsAgents read, check, score and calculate. They do not move an account or send a bill. A rates analyst clears each cell, and the rates and tariffs manager signs each back-bill and each refund over $5,000.
The limits are held, both waysA back-bill for the utility’s own error reaches back 12 months at most, with installments over as many months as were billed back. Over-charges are refunded for the whole period on record, up to 84 months.
Key accounts see it firstAny account with a connected load of 400 kVA or more goes to the key account manager too. That way the customer hears about the correction before the letter arrives.
Each change on the recordEach agent step and each decision is recorded with its time, including who cleared, who signed and what was sent. A settings change is saved as a new rules version, and the rebill keeps both tariffs month by month.
Configuration

Back-bill limit, refund lookback and sign-off for rate code validation

The rates team sets the back-bill limit, the refund lookback, who signs and how strict the checks are. Each change is saved as a new rules version.

SettingDefaultChoose from
Back-bill limit when the error is the utility's12 months1 to 24 months. How far back a corrected account may be billed.
Refund lookbackWhole period, up to 84 monthsWhole period, up to 60 months · up to 84 months · up to 120 months
Manager sign-off$5,000$2,000 · $5,000 · $10,000. Refunds above it, and each back-bill, need the rates and tariffs manager.
Nightly checkEvery night at 01:00Every night at 01:00 · Every night at 03:00 · Every Sunday at 01:00
Usage shape confidence0.800.60 to 0.95. The lowest template match that counts as a signal.
Two signals before an account movesOnAlways on. The usage shape alone never changes a tariff.
Look again at amber cells90 days30 days · 60 days · 90 days
Key accountsOnOn · Off. Accounts with a connected load of 400 kVA or more go to the key account manager too.
Connections

Tariff book, accounts, premise and license registers, and meter data

Tariff book and rate schedulestariff codes, eligibility clauses, riders, retired codes and amendments
Billing and customer accountsrate code, tariff history, premise type and connected load
Premise registerpremise number, type and the account at the premise
Licence, tenancy and land registersbusiness licenses, leases and title deeds
Meter data90 days of hourly reads, export reads and peak demand
Connectionsload upgrades, demand meters and solar connection certificates
What it changes

Refunds paid and under-billing recovered by rate code validation

Each figure carries its label: a target the solution is built to, an estimate, a typical published result, or a proven one.

target
100%
of over-charged customers refunded before they have to complain
demo
$3.4M
a year of wrong tariffs put right: refunds paid, under-billing recovered, the sample's figure
target
12months
the most any back-bill reaches back, with every month shown
12-month limit
refunds go back further

“demo” means seen in the working solution, on its sample accounts. “target” means the design goal, measured in the live solution. “estimated” means our arithmetic on sample inputs. The $3.4M is 1,312 accounts found in one nightly check × $2,590 average yearly difference. The working-days split is our estimate. “typical” means published figures. The Nevada Independent and KOLO (2026) reported NV Energy refunding more than $63M with interest for about 43,000 homes billed on the wrong rate class. Vermont Business Magazine (2014) reported that Burlington Electric over-billed the city by $1.78M. Back-billing limits named for context are Fla. Admin. Code 25-6.106 and 25-30.350, with 12-month limits for electric and water service, and Utility Regulator NI, with 13 months. New York bill S8530 (2025) would require a misclassified account to be moved to the right rate code. Names on the screens are sample data.

Questions

Rate code validation questions from rates and billing teams

What is rate code validation software?

Rate code validation software checks that each utility account is on the tariff, or rate code, it qualifies for. When it is not, the software works out the refund or back-bill. Rate Code Validation checks each account each night against the eligibility rules in the tariff book. A rates analyst then clears each account it flags.

How does rate code validation work?

Six agents share the work. They read the tariff book into rules tied to their clauses and profile each account. They check the licenses, tenancies, deeds and certificates at the premise and score 90 days of hourly reads. Then they rebill each month on the right tariff. Each broken rule becomes a red cell with its clause, its proof and its money.

How does it find a business billed on a residential tariff?

It reads how the meter is used as well as the record. A shop's flat load during trading hours, or a home's evening peak, is scored against shape templates. A matching business license or tenancy confirms it. In the sample, a grocery billed as a home scored 0.88 on the shop template and held an active business license.

Can the usage shape alone change a customer's tariff?

No. The shape is one signal. A license, tenancy or record must agree before an account moves, and that rule cannot be switched off. With one signal the cell stays amber and the account is looked at again after 90 days.

How are refunds and back-bills for misclassified accounts worked out?

The rebill calculator prices the same kWh and demand on the right tariff for each month, with VAT, and shows both prices. Over-charges are refunded for the whole period on record, up to 84 months. Back-bills for the utility's own error stop at the back-bill limit, 12 months in the sample, with installments.

Who has to sign before a customer's tariff changes?

A rates analyst clears each cell. The rates and tariffs manager signs each back-bill and each refund over $5,000. Accounts of 400 kVA or more go to the key account manager too. The agents read, check, score and calculate, but they do not move an account or send a bill.

What happens when the tariff book changes?

An amendment is added on the Tariff book screen. The tariff book reader reads it into rules and shows what would change before anything is published. Then the rates and tariffs manager publishes it. Retired codes move to the code that replaces them. A recode that does not change the price needs no rebill.

What do we share to run the first nightly check?

Your tariff book, billing rules, letter templates and a sample of accounts. The Agentic Solution Engine builds and deploys the solution from those requirements and documents. It goes live once each quality gate has passed. We will walk you through it on your own accounts first.

Run rate code validation
against your own tariff book.

We'll run Rate Code Validation on your own tariff book and a sample of your accounts.