- Before
- Checks the biggest bills in the key-account run in a spreadsheet next to an interval export. Knows that a wrong bill still adds up, which is how it gets through.
- Now
- Opens each stopped bill beside its own 15-minute data. Each billed number is drawn on the readings, and each difference is explained and cited. Stops or releases the bill, with the corrected bill already drafted.
A cold store's September bill, stopped the morning before release
The utility builds its September key-account run on the night of the 10th. The run holds the month's demand-billed draft bills, and the release window closes at 18:00 on the 13th. One of them is for a cold store at a logistics park that added a blast-freezer line in September. Here is what happens to its bill, screen by screen, in the working solution.
A worked example on sample data. Names, IDs and figures on the screens and in this section come from the demo.
- 01Overnight
Each draft bill checked, the whole run
Monthly key-account runThe run is built at 22:00 on the 10th. Each draft is checked against its own 15-minute data, contract and meter records. By morning the release run shows each bill as a dot, placed by money at stake. Most passed all checks. Another 39 are for review, with an explained difference inside the stop rule. And 9 are stopped, with $193,795 of errors: $77,215 over-billed and $116,580 under-billed. Their causes run from a PT ratio keyed wrongly to a winter on-peak window used for a summer month.
Stop rule: more than $1,000 or 0.5% of the bill
- 02Morning
The draft bill, beside its own 15-minute readings
Key-account billing specialistThe specialist opens the cold store's account. On the left is the September bill as the customer will see it, line by line, marked DRAFT · NOT RELEASED. It totals $531,919.53. In the middle are the month's intervals, with the billed demand of 2,480 kW drawn as a dashed line across them. The true interval peak is 2,140 kW, on the 29th at 14:45. That gap of 340 kW is worth $13,940.00 on the demand charge.
“Recommended: stop · $14,783 over · the specialist decides. A stopped bill is held until its correction is released.”
- 03Seconds per agent
Six agents read the bill, the contract and the field order
The check runThe specialist runs the checks again to watch them. The draft bill reader finds 7 lines, with billing demand taken from the maximum-demand register. Next, the contract and tariff reader reads the special supply agreement and its second amendment. It finds 7 billing terms and cites each one. The meter configuration checker finds the field order for a CT change. The interval recalculator rebuilds demand from 2,880 intervals, none estimated. Each step takes between 1.4 and 2.1 seconds.
“Field order: CTs 200/5 → 300/5 on the 22nd at 10:40 · multiplier 4,800 → 7,200 · billing applied 7,200 to the whole month’s register”
- 04The cause
An old peak, scaled with the new multiplier
Meter configuration checkerThe meter crew replaced the CTs on the 22nd for the new blast-freezer feeder. With the existing PTs, that took the multiplier from 4,800 to 7,200. The register's highest value was set on the 16th at 14:15, under the old CTs. It read 1,653 kW at ×4,800. Billing read the register once at month end and applied ×7,200 to it, giving 2,480 kW. The account's history shows twelve months billed at their interval peak. September is the first billed above it.
“CTs replaced 200/5 → 300/5 · multiplier 4,800 → 7,200 · for the new blast-freezer feeder”
- 05The contract
The clause the draft did not follow
Contract and tariff readerThe special supply agreement opens with each billing term highlighted and cited in the margin. Peak is the highest of the month's fifteen-minute intervals (5.1). Contract demand is 1,500 kW (5.2). The ratchet is 75% over 11 months (5.4). On-peak runs 12:00 to 18:00 from May to October (6.2). A power-factor adjustment applies below 0.90 (7.1), and any correction needs a written note (9.1). Clause 8.3 is marked “Not followed on the September draft”.
Clause 8.3: “the billing determinants shall be computed separately for each part of the period, using the ratio in force for that part.”
- 06Line by line
Power factor: the right rate on the wrong base
Interval recalculatorCapacitor bank 2 was out from the 9th to the 15th. The month's average power factor is 0.89, from 1,102,670 kWh and 564,890 kVArh, and clause 7.1 adds 1%. But the 1% was taken on a demand charge built from 2,480 kW. On the true demand it is $4,154.33, against the $4,293.73 drafted. Time-of-use energy agrees with the intervals within 0.01%. It was split at the CT change as clause 8.3 asks, so it needs no change.
“The 1% adjustment is right; what it is 1% of is not.”
- 07Mid-morning
The specialist stops the bill, with the reason on the record
Key-account billing specialistThe reason is drafted from the evidence. Billing demand of 2,480 kW is the register peak of the 16th, scaled with the new multiplier of 7,200. The interval peak is 2,140 kW, on the 29th at 14:45. Clause 8.3 was not applied. The specialist signs the stop with their own account. Releasing the bill as drafted would have needed a written reason too.
“Bill stopped by the key-account billing specialist, signed with the specialist's own account.”
- 08Stopped
What the wrong peak would have done next
Variance explainerThe bill is held, and the customer sees nothing until the corrected bill goes out. The variance explainer shows why stopping it matters beyond September. Under clause 5.4, a 2,480 kW peak would hold a ratchet floor of 1,860 kW until next August. The true floor is 1,605 kW. On the winter load forecast, that is 1,105 kW-months over-billed from November to April.
“1,105 kW-months over-billed, Nov to Apr · $45,305”
- 09Five minutes later
The corrected bill is signed and released
Key-account billing specialistThe correction and note writer has drafted the corrected bill beside the draft, line by line. Demand drops from 2,480 to 2,140 kW (−$13,940.00). The power-factor adjustment falls $139.40 and tax falls $703.97. Now the total due is $517,136.16, which is $14,783.37 less. The next 11 bills are listed with the wrong and the true ratchet floor. The specialist signs and releases it in place of the draft.
“Corrected bill released by the key-account billing specialist”
- 10Before the bill lands
The customer hears it from the utility first
Key account managerThe note goes to the key account manager to approve and send to the customer's energy manager, with the finance controller copied. It says in plain words what was found. Larger current transformers went in for the blast-freezer line. Billing scaled the peak of the 16th with the new ratio. The 15-minute readings show a peak of 2,140 kW. The bill and the interval readings are attached. No agent sends anything to a customer.
“Your September bill is $517,136.16, $14,783.37 less than it would have been. The correct peak will be used for your demand floor over the next eleven months.”