Device History Record Review by Exception

Device history record review that reads each page against the spec in force on the build date, and stops a serial only where its record fails.

Follow 24 tables from 08:02 to release at 08:26 ↓
Watch with transcript →
The problem

Quality reads a whole history record to find the one line that is wrong

Finished tables sit in quarantine while a reviewer reads each serial’s record against the device file and each signature against the procedure. Most of those pages are clean, so most of that reading finds nothing, and the release clock runs while it happens.

The misses hide where a tired reader rarely looks. A value passes today’s limit but not the limit in force on its build date, because the traveler was printed on the old form. A good reading came from a tester whose calibration lapsed the week before. One verifier box stays blank among dozens of signatures.

Built forQA release specialistsRecord reviewersProduction supervisorsSite quality directors

The Problem Today

Every finished device waits while quality reads its whole history record, though most pages hold nothing wrong.

400K
lot and serial records closed yearly by one large maker our estimate

Checked by hand today

  • Travelers
  • Test prints
  • Revisions
  • Calibration
  • Old limits on old formsA form printed before a change still says pass
  • Lapsed testers read fineA good number from an expired tester looks good

The Solution

  1. Read each pagePaper travelers, test printouts and label prints, value by value
  2. Use the spec of the dayEach value against the revision in force on that serial’s build date
  3. Check the tester’s dateEach test instrument’s calibration on the day of the test
  4. Stop only what failsA stopped serial goes to the person who can fix it, with its page

Built-in controls

  • Agents never release, hold or close a serial
  • The reviewer opens a sample before signing
  • Release takes a second person and an e-signature

What You Get

Clean devices leave quarantine the morning their records arrive, and a named person decides each stop.

$4.8M
yearly at one large maker, in hours, failures and cash our estimate
  • A release file people signedOne row per serial, with its signer and its reason
  • Evidence an auditor can followWho opened, decided and signed what, and why
  • Each tester checked on the dayA lapsed calibration found before release, not after
One work order, one morning

Device history record review on one work order: 1,136 pages, three stops

Twenty-four powered surgical tables, built over a week and packed, wait in quarantine for their records. The last scanned page lands at 07:38, and this is what happens next.

demoThe plant, its tables, the people and each reading are sample data.

  1. 0108:02

    1,136 pages in for 24 tables, and not one of them read yet

    QA release specialist

    The last page reached the scan station at 07:38: 848 traveler pages plus test printouts, exports and label prints. The route card lays out the 19 stations of the routing with each serial still in the pages-in bin. Release is due within two working days of the last operation, and the clock shows 34 hours left.

  2. 0208:06

    Twenty-one serials reach ready for QA, and three stop where their records fail

    QA release specialist

    Seven agents read the pages and walk each serial’s tag along the routing. Twenty-one reach ready for QA. Three stop with a reason chip: 0422 at torque verification with a signature missing, 0409 at the lift load test, already asked of the production supervisor, and 0417 at electrical safety, tester out of calibration. Two need her decision.

  3. 0308:06

    Two tables drifted 4 mm, and only one of them is out of limit

    QA release specialist

    The spec in force view puts each serial on its kitting date. Rev D of the device file took effect the day 0409 was kitted and tightened lift drift to 3 mm or less. Its traveler was still the rev C form, which printed 5 mm and said pass. Serial 0403 also drifted 4 mm, built under rev C, and is correctly clean.

  4. 0408:06

    Each value within limit, and still a stop: the analyzer was past its due date

    QA release specialist

    Earth leakage 212 µA against a 500 µA site limit, touch current 38 µA: the printout passes. The safety analyzer was due for calibration two days before this test ran, and the other 23 serials were tested on a second analyzer. The agents’ plan ends in a proposal: hold for a retest on that one, which the test technician can run today.

  5. 0508:06

    The calibration record: out at the lab, with its as-found result not back

    QA release specialist

    One citation opens the calibration record as the calibration system exported it: a 12-month interval, due two days before the test, out for calibration since the day after it, as-found result not back. Below it the panel notes that earlier results must be assessed when equipment is found not to conform. Close with a reason stays shut until that result is in.

  6. 0608:13

    The reviewer opens three sampled clean serials, then signs for all 21

    Device history record reviewer

    The sample is drawn at random when the read finishes: 10% of the clean serials, at least 3, here 0403, 0412 and 0420. His sign button stays shut until each one is open. He signs the review of the 21 with his password at 08:13, and the release step lists them ready, noting that he cannot release what he reviewed.

  7. 0708:21

    A blank verifier box cannot be filled after the fact, so 0422 goes back

    QA release specialist

    Four column-to-base bolts were torqued within spec, but the verifier box on traveler page 22 is blank. She has already held 0417 for a retest, which takes effect at once. For 0422 she picks the reason code, second-person verification missing, and signs it back to production for a witnessed re-check and a late entry.

  8. 0808:26

    Twenty-one tables released the morning their pages arrived

    QA release specialist

    She opens one clean record herself, as the settings require, then releases the 21 under her e-signature, meaning released for distribution. The route card moves them to the released bin. Three are still out, each with its owner: 0409 with production, 0417 held for a retest, 0422 sent back. The agents release nothing and hold nothing.

  9. 0908:26

    Only a release signature moves a serial out of quarantine in the ERP file

    QA release specialist

    The release file the ERP loads holds one row per serial: release or keep in quarantine, the reason, who reviewed, who released and the signature meaning. The router rebuilds it after each decision. Twenty-one rows read release, and 0409, 0417 and 0422 stay in quarantine with their reasons, so no serial leaves on a default.

Same 4 mm of drift, two build dates, two different answers

Six tables were kitted under rev C and eighteen under rev D. Each value is held to the limit in force on its own build date.

SerialsRevision on the build dateDrift against the limitResult
0403Rev C4 mm against 5 mm or lessIn limit, not stopped
0409Rev D4 mm against 3 mm or lessOver the limit, stopped
0401 to 0406Rev CSix serials on the old limitHeld to rev C
0407 to 0424Rev DEighteen serials on the new limitHeld to rev D

demoSample data, from the working solution. Against today’s rev D, 0403 would fail. It was built before rev D, so it is not flagged.

About 18 reviewer hours a work order, down to about one

Our estimate for this work order, from line-by-line reading against the records a person opens here.

Serials in the work order24
Reading one record line by line45 min
Reading the whole work order by handabout 18 h
Records a person opens here3 sampled clean serials, 2 stops, 1 more clean record6
At about 10 minutes eachabout 1 h

estimatedOur estimate.

Around the release

The rest of the record, the floor’s questions and the release trail

What the reviewer, production and the site quality director see on the same work order.

One serial’s recordStation by station: each value against the limit in force, the instrument and its calibration on the test date, who signed and who verified, and the source page.
Label and UDI checkEach printed label against the record and the label spec: device identifier for the configuration, serial and manufacture date. All 24 match here.
Production and testOne question per serial, each with its page, for production and test. Each answer is checked again by the agents before anyone can release.
Who agreedRead by the agents at 08:06, reviewed at 08:13, released at 08:26, with each open stop and its state. Reviewer and releaser are different people.
Audit trailEach read, opening, decision and signature in order, people and agents alike, with the reason and the signature meaning. The site quality director can export it.
Stop rulesWhat stops a serial, the sample and the release clock. Calibration, signature and unreadable-page rules are locked on, and a looser change starts on the next work order.

demoSample data, from the working solution.

QA release decides each stop, and the reviewer never releases

Holding or sending back takes effect at once. Closing a stop with a reason waits for a second person.

QA release specialist
Sees
Each stop with its page, its source and the agents’ plan
Signs
Holds, sends back or closes each stop, and releases clean serials
Device history record reviewer
Sees
The sampled clean serials and each typed note in its exact words
Signs
The review of the clean set, and a countersignature on any close
Production supervisor
Sees
One question per serial with the traveler page
Signs
Nonconformances, witnessed re-checks and late entries
Test technician
Sees
Which test to rerun and on which instrument
Signs
Retest results, and no release
Calibration coordinator
Sees
Each record measured on an instrument after its due date
Signs
As-found results from the calibration lab, and no record decisions
Site quality director
Sees
The release clock and the full trail
Signs
Nothing: read only, with exports for audits
The agents

Seven agents read and check each page; none of them releases a serial

Each has one check and hands what fails to the router.

Record reader

Reads traveler scans, test printouts, execution entries and label prints, and maps each value and signature to its serial and station.

  • Never guesses an unreadable value
Spec-in-force checker

Finds the device file revision in force on each build date and the traveler form actually used.

  • Never applies today’s revision to an earlier build
Value checker

Checks each recorded value against the limit in that revision.

  • Never rounds a value to pass
  • Never accepts pass without the number
Instrument checker

Looks up each test instrument’s calibration status on the test date.

  • Never accepts a value from an instrument out of calibration on the test date
Signature checker

Checks performer and second-person signatures, dates, corrections and late entries.

  • Never signs, initials or fills a blank
Label and UDI checker

Compares each label print with the record and the label spec.

  • Never prints or reprints a label
Router

Sends each stop to the person who can fix it with the page, keeps the clock and rebuilds the release file.

  • Never releases, holds or closes a serial

Seven systems a release reads, and one file it writes

Each system is read in place. The only thing written is the ERP release file, one row per serial.

Manufacturing execution systemTest-station entries and work orders
Scan stationPaper traveler pages as they arrive
Quality management systemNonconformances, as signed references
Product lifecycle managementDevice file revisions and change orders
Calibration management systemInstrument due dates and certificates
Label printing systemThe label print log
ERPReceives the release file; serials leave quarantine only on a release row

What QA release teams ask about device history record review

What is device history record review by exception?

Device history record review by exception means people read only what fails. Agents read every page of each serial’s record, check each value, signature, instrument and label, and stop a serial only where something is missing, out of limit, unsigned or measured on an out-of-calibration instrument. A reviewer samples the clean serials and QA release decides.

What counts as an exception?

A missing value, or one out of limit against the revision in force on the build date. An instrument out of calibration on the test date, or a missing or late signature. A label mismatch, an unreadable page, or a traveler form that differs from the revision in force.

Does DHR review by exception work with paper travelers?

Yes. Scanned traveler pages, test-station printouts and label prints are read alongside electronic entries. Handwriting the reader is unsure of is checked against the matching export, and an unreadable page stops the serial with a request to rescan.

Who releases the serials?

The QA release specialist, under her own e-signature with its meaning. The reviewer and the releaser are always different people, and the agents release nothing.

What happens when a tester was out of calibration?

Each result measured on it after its due date stops, however good it reads. The calibration coordinator owns the impact list and records the lab’s as-found result; until it is back, a stop cannot be closed with a reason.

Can a stop rule be relaxed?

The administrator proposes and QA release approves with an e-signature. A looser rule starts on the next work order, a tighter one at once, and the calibration, signature and unreadable-page rules stay locked on.

What about a unit held by complaint handling?

It shows as one signed reference that stays unopened by the agents, and the serial cannot be released from here.

Bring one work order’s records
and the spec it was built to.

We’ll read each page and show you which serials stop, and why.