- Sees
- Replays, the rows they reopen and the team queue
- Signs
- Reopens rows, drafts revisions, sends study requests; signs nothing he drafted
A biological evaluation plan reopened by the blue masterbatch in a shaft
An irrigated ablation catheter family with 22 product codes, 14 materials and 31 test reports. The tubing supplier changes the carrier resin and dispersant behind the shaft's blue color.
demoThe catheter family, the supplier, the people, the study numbers and the chemistry values are sample data.
- 01Morning
12 rows closed in revision C, and a change record against the shaft jacket
Biocompatibility specialistThe map draws the catheter from the femoral vein to the left atrium, with four numbered contacts: tip and ring electrodes, shaft, irrigation fluid path, and the handle in a gloved hand. Beside it sit the rows the plan must address, each with its kind of cover and its sources. A yellow banner says a change record alters the shaft jacket colorant.
- 02Replay
9 of 12 rows rest on evidence made with the old masterbatch
Biocompatibility specialistHe runs the replay. The agents read the change record and supplier notice, find the proximal jacket material in 22 of 22 product codes, and pull the chemistry and finished-device tests made with the old masterbatch. Then they split the rows by what each stands on: 4 on chemistry, 5 on tests of the finished device, 3 untouched because the handle holds no PEBA.
- 0309:11
Four rows reopen at once; five stay closed, waiting for the toxicologist
Biocompatibility specialistReopening is the safer move, so it takes effect when he clicks. Keeping the five tested rows closed is the looser move, so each one now reads closed, to confirm, and waits for the toxicologist to open it and agree. Their test article was the finished catheter with the old masterbatch, so they stand only if the new jacket proves chemically equivalent.
- 0409:14
Revision D leaves the four reopened rows open for a study she will choose
Biocompatibility specialistThe drafter writes plan revision D from the replay: what changed, the four rows reopened, the eight that stay closed, the ethylene oxide residual check on the first three lots with the new jacket, and who signs. Each reopened row is to be closed on a study the toxicologist adds. The specialist sends it for signature. He cannot sign a revision he drafted.
- 0509:20
The old animal test ran on one curve only, so it cannot close this row
ToxicologistAcute systemic toxicity rests on chemistry. Her screen shows the sum: a threshold of 3.0 µg/mL, which is 60 µg per device, and margins of safety of 17, 14 and 162 for the three compounds above it. The animal test covered the unidirectional U1 curve only, so it stays as support. A row counts as read only after 3 seconds on screen.
- 0609:35
Signed at 09:35, after she opened all four rows and added the comparison
ToxicologistSigning stayed locked until each reopened row had been read. She adds CC-26-058 to the plan: the new jacket against the old, polar, semi-polar and non-polar solvents, the same 3.0 µg/mL threshold. She re-enters her password and signs with the meaning shown: approval of this plan revision as the basis for the biological evaluation. Both study requests can now go to the lab.
- 0709:38
The filing question goes to the change team; the agents decide no filing
Regulatory affairs specialistShe logs FQ-26-212 in the regulatory information system: does the masterbatch change need a premarket supplement or a 30-day notice, and a change notification for this class III family. Beside it sit the checks the planner proposed, three devices each with the same solvents, and residues on the first three lots. The panel says plainly that the toxicologist adds studies, and nothing else does.
- 0809:38
The trail holds four separate reads before the one signature
Regulatory affairs specialistTwenty entries so far. Each read of a reopened row is its own line, three minutes apart, each marked as on screen for more than 3 seconds before deciding. Then the study added, the signature with its meaning, and her filing question in her own words. Agent steps are logged too. The trail is kept for the life of the device plus 10 years and downloads as a CSV.
- 09Afternoon
The map now marks the changed jacket in orange, and the report waits
Biocompatibility specialistBack on the map, the changed proximal jacket runs in orange along the shaft, and the row list counts 4 reopened and 5 to confirm. The banner says revision D is signed and that the report stays blocked until each planned study returns: the residual check and the extractables comparison. His next stop is the study requests.