- Before
- “Don't tell me the clock — tell me the overnight where I can actually fix it.” Matches clocks to routings, stock and rosters by phone.
- Now
- Opens a board with the slot already proposed, checked twice and explained; approves, moves it or asks for a tail swap, with a reason code.
One MEL deferral, from a running clock to a planned fix
Corvane Airways runs 300 aircraft from its Denver hub. On the night of Tuesday, October 6, at ORD, the crew of N818CV, a 737-8, wrote up “TAT PROBE HEAT caution on descent; reset, no effect.” The heater element was open, and the item was deferred under MEL 34-11-02, Category C. Here is Monday morning in the working solution: the maintenance controller works with the agents in plain conversation, sees the evidence behind every answer, and signs the decision.
- 01Monday, 06:40
412 open deferrals, and six need a person
Rosa Delgado · Maintenance Controller, MCC DenverRosa's Today screen shows 412 open deferrals on 214 of 300 aircraft, 73 clocks inside 72 hours with 70 already fix planned, 6 that need a person — 3 of them hers — and 0 past their limit since go-live on March 2. The clock agent's morning briefing names the first one: N818CV, expiring Friday at 23:59.
Clock agent: “First: N818CV, Category C, expires Fri 23:59 — we found Wednesday at DEN with the part and the people.”
- 02The board
The board, the proposal, and a second agent that checked it blind
Rosa Delgado · Maintenance ControllerFix slots draws every tail with an open MEL item as its next ten days of flying, the deferral clock running under it to its expiry, and every overnight and long turn marked as proposed, possible or no fix here. Beside the board, the slot finder agent proposes Wednesday, October 14 at DEN, 22:50–05:55: 2 probes in bin H4-12-03, Kai Ramos and Dee Walsh free 23:30–02:30, a 2 h 25 job, and 1 d 21 h left on the clock after the fix, at confidence 0.93. The check agent recomputed the clock without seeing that answer, and agrees.
Check agent: “I recomputed it without seeing that answer: Category C, day of discovery Oct 6 excluded, so the clock expires Fri, Oct 16, 23:59 MT. The plan is legal and the (M) procedure closes on return to service. I agree. Thursday at ORD stays the backup.”
- 03A question
She asks the agents what could go wrong
Rosa Delgado · Maintenance ControllerRosa types her question into the conversation beside the board: what if the IAH flight Wednesday runs late? The slot finder agent answers with the numbers and cites the task card and the ORD night roster it read. Nothing she asks books or moves anything; the answer only tells her what the plan can absorb.
Slot finder agent: “The window is 23:30–02:30 for the people, and the aircraft can land as late as 00:05 and still fit the 2 h 25 job. Later than that, Thursday at ORD is the backup; I would tell you by 23:00 Wednesday.”
- 04Run again
Seven steps, each with what it read
The agentsRosa asks the agents to run again and watches each step. The clock agent reads tech log TL-818-04471 and MEL 34-11-02 at Revision 41. The slot finder reads N818CV's routing for Oct 12–21: five overnights before expiry, and SAN and LAS have no Corvane maintenance. The parts agent finds TAT probe P/N 0912DC-4 at DEN 2, ORD 1, SFO 0. The crew agent reads the night rosters for avionics-authorized technicians.
“Nothing is reserved, booked or sent until a person approves.”
- 05Four overnights
Why Wednesday at Denver wins
Slot finder agentThe fix plan scores the four overnights the agents checked before expiry; Monday night at SAN has no Corvane maintenance and is not scored. Tuesday at SFO scores 0.48: no probe, and 4 of 4 avionics technicians booked. Wednesday at DEN scores 0.93: 2 probes in bin H4-12-03, Kai Ramos and Dee Walsh free, 1 d 21 h left after the fix. Thursday at ORD, 0.71, is the backup — 21 h left is under the 24-hour planning margin. Friday at LAS, a contract station, is not viable.
The job: task card 34-11-21-000-801 (2 h 00) and the operational test (0 h 25), inside a 3-hour window with 35 minutes spare.
- 06Signed
She approves with a reason code and her e-signature
Rosa Delgado · Maintenance ControllerRosa picks reason code P1 — earliest slot with part, people and time — and signs. She could instead use another slot, ask the OCC for a tail swap, or reject the plan and send the agents back with an instruction.
“I approve this fix plan as Rosa Delgado, Maintenance Controller — e-signature.”
- 07Fix planned
The part reserved, the people booked, the work order released
Parts, crew and records agentsOnly after her signature do the agents act: the parts agent reserves probe S/N 7741 in bin H4-12-03 for work order WO-26-88412, the crew agent books Kai Ramos and Dee Walsh on the DEN night shift, and the records agent releases the work order to DEN line. N818CV's lane now reads Fix planned, and the warning ladder is paused while the plan holds.
- 08Before the COMAT cut-off
Part moves on named flights, for stores to approve
Luis Ferreira · Stores PlannerWhere the best overnight lacks the part, the parts agent proposes the move. N411CV needs a first officer wiper motor at EWR: P/N 2W-5532-1 from DEN bin W2-04-11 on CV 618, Monday 11:20 → 16:58, for the Tuesday EWR fix — COMAT cut-off 10:20. Luis approves the three moves one by one or together.
“Nothing ships until the stores planner approves.”
- 09No slot before expiry
An extension drafted, never granted
Records agent · for Grant Whitcomb, Director of MaintenanceN836CV's Category B cowl anti-ice valve indication expires Tuesday at 23:59, and no valve reaches SEA until Wednesday 10:00. The records agent drafts a one-time 3-day repair interval extension to Friday 23:59 and the FAA notice; the check agent confirms eligibility. The other way is shown too: refuse, and the OCC covers with a spare 737-8. For N918CV, Rosa's tail-swap request is already in the OCC's queue.
“Drafted by the records agent; sent only by the Director after approval.”
- 10Third time in 30 days
The cause, not a third indicator
Repeat-defect agent · with Owen Price, Reliability EngineerN827CV has its third deferral of MEL 28-41-02, center tank fuel quantity indication, in 30 days; the indicator was replaced twice. The repeat-defect agent reads both work orders and the wiring data: both reports came after rain at IAH, and tank wall connector D4072 carries both signals. It proposes troubleshooting D4072 at DEN on Thursday, at confidence 0.78.
“Rosa Delgado or Owen Price decides · a third indicator is not proposed.”