Before a new medicine reaches people, laboratory studies test it for harm. Each study ends in a final report under Good Laboratory Practice, or GLP: one signed document that gathers the plan, the data, the specialists' reports and a quality assurance statement. A regulator's reviewer may see only that report, so every number in it has to match the records underneath.

This guide is for anyone who writes, checks, signs or pays for GLP study reports: study directors, contributing scientists, report coordinators, quality assurance auditors, test facility managers, sponsors' toxicology leads and the people deciding whether to automate toxicology report writing. No background needed. It covers documents and decisions only, and how to run a study is outside it.

See one case, screen by screen →
Watch with transcript →
A quick example · fictional

Imagine you are a study director at a contract laboratory. Your 28-day study of a fictional antibody, Veltrimab, code VLT-TOX-028, has ended. The data package reached you on Monday, October 5, 2026, and the draft report is due on October 16. You will sign for every number in it.

Section 4.2 needs food consumption for the males in Group 4. Weeks 1 to 3 read 24.6, 25.1 and 25.7 grams per animal per day. Week 4 is empty. The study log says a technician weighed the food on September 12, and that day's balance file never reached the export.

The easy move is to reuse 25.7 from the week before. The table would look complete, the four-week mean would appear, and nothing on the page would show that the Week 4 figure is a copy of Week 3.

Export of Oct 5 · sheet FC_Males
Week 3, Group 4
25.7
Week 4, Group 4
empty (cell E5)
Weeks 1 to 4 mean
empty
Corrected export of Oct 6, signed
Week 3, Group 4
25.7
Week 4, Group 4
25.9
Weeks 1 to 4 mean
25.3
1 empty cell1 record to findand one sentence that waits until it is found.

So you ask the technician. She sends a corrected export, the first one stays on file, and the sentence is written from the real value, 25.9. Had the value been lost for good, the report would say "not recorded".

Careful report work catches the blank that someone could have filled, and leaves the study director a report where every number leads back to a record.

Preclinical Study Report Automation guide
Part A · Understand it

GLP study reports in full: 21 CFR 58.185, OECD rules, raw data, QA statements, signatures and where the rules stand in 2026

What a final report must hold, who answers for it, how its numbers go wrong, what inspectors cite and what regulators say about AI, explained without selling anything. It stays with documents and decisions. If you are new to toxicology, start here.

01 · In plain words

A GLP final report is the one document that speaks for a finished laboratory study

A company developing a medicine has to show regulators what the medicine did in laboratory studies before it can test it in people, and again at later stages of development. Each of these nonclinical studies, meaning studies done outside the clinic, follows a written plan. Many follow a set of record-keeping rules called Good Laboratory Practice, or GLP. Those rules say who is responsible, what has to be written down and how long it must be kept.

One named scientist, the study director, is the single point of control for each study. When the work is over, technicians and specialists have produced thousands of records: weights, laboratory values, the pathologist's findings, the concentration measurements. A few specialists write their own signed reports. Those records and reports are the raw material, and the study director turns them into the final report.

The final report does three jobs. It says what was planned and what actually happened. It summarizes the data in tables and sentences. And it states the conclusions, in the study director's name. A separate group, quality assurance, checks that the report matches the records and adds a signed statement saying when it inspected the study. Then the study director signs and dates the report, and it goes to the archive and to the sponsor's filing.

The hard part is copying with care. The same value can appear in a data sheet, a table, a results sentence, a summary and a conclusion. People usually move it by hand and check it by hand, and they have to keep all those places in agreement when a late correction arrives. A reviewer at the agency may never see the underlying records, so the report has to be right on its own.1

From the last study day to a signed GLP report, in five steps

  1. The study ends and specialists finish their workVLT-TOX-028's recovery animals complete their period on September 29, 2026. Pathology and toxicokinetics reports follow.
  2. The data package reaches the study directorOn October 5: the signed plan and amendment, data exports, one signed contributor report and the report template.
  3. The report is written and checked against the recordsTables, results, summary and conclusion, with every number traced. Missing values and missing data are chased here.
  4. Quality assurance audits, and its statement is preparedQA compares the report with the raw data, reports what it found and signs a statement of its inspection dates.
  5. The study director signs, and the records go to the archiveA later change can only be made by a signed amendment that says what changed and why.

Step 3 is the subject of this guide, with its hand-offs to steps 4 and 5. The study, people and figures in this example are fictional.

What surprises people new to GLP reports: a one-page rule, a list of dates, exports and separate signatures

The US rule fits on one page

21 CFR 58.185 lists 14 items and three short paragraphs on signing and correcting. Its text dates to 1978, with changes in 1987, so most of a report's shape comes from house templates.2

QA's statement lists dates

Under FDA's rule, the statement specifies when inspections were made and findings reported. The check against raw data is a separate duty, and OECD asks the statement to confirm it as well.3,4

An export may fall outside "raw data"

FDA answered in 1981 that a printout derived from data transferred from laboratory sheets to computer media is not raw data, while a printout from a controlled data-acquisition system can be. What an export counts as depends on how it was made.5

Specialists keep their own signatures

In its 2016 proposal, FDA declined to let one integrated report replace individual scientists' reports. Merged reports, it says, "would obscure the individual scientist's accountability".6

Study director, raw data, QA statement and amendment defined

Study director

The scientist who "represents the single point of study control" and answers for how results are interpreted, documented and reported.7

Raw data

Original records of the study's observations, or exact copies, "necessary for the reconstruction and evaluation of the report".8

QA statement

A statement signed by quality assurance and included with the final report, giving inspection dates and when findings were reported.3

Amendment

The only way to correct or add to a signed final report: a signed, dated addition that names the part changed and the reason.2

Fourteen terms are defined in the one-page summary.

02 · What a final report must hold

The 14 items in 21 CFR 58.185, and where a study director gets each one

In shortFDA's GLP rule names 14 things a final report "shall include", and leaves the order and the headings to you. Four come from the approved protocol and six from facility and test article records. Two are written by the study director from the data, and two are other people's signed documents. A report can follow every heading in a template and still miss one.

The regulation opens with a floor: the report "shall include, but not necessarily be limited to" the list.2 It gives no section numbers and no required order. A house template with nine sections and a template with forty can both carry all 14 items, and each item needs checking on its own. That is why an audit against the template and an audit against the rule can find different things.

58.185(a)What the report must carryWhere it comes fromWhere a typical template puts it
(1)Facility name and address; dates the study started and finishedFacility records, study fileTitle page, introduction
(2)Objectives and procedures in the approved protocol, with any changesProtocol and amendmentsIntroduction, methods
(3)Statistical methods usedProtocol, statisticianMethods
(4)Test and control articles: name or code, strength, purity, compositionTest article recordsMaterials
(5)Their stability under the conditions of administrationTest article recordsMaterials
(6)A description of the methods usedStudy file, standard proceduresMethods
(7)The test system: for animals, number, sex, weight range, source, species, strain, age, identificationProtocol, then study recordsMethods
(8)Dosage, regimen, route and durationProtocol, then study recordsMethods, design table
(9)All circumstances that may have affected the quality or integrity of the dataWritten by the study directorDeviations, compliance section
(10)Names of the study director, other scientists and supervisory staffFacility recordsPersonnel page
(11)Transformations and calculations, a summary and analysis, and the conclusionsWritten by the study director from the dataResults, discussion, conclusion
(12)Signed and dated reports of each individual scientistContributing scientistsAppendices
(13)Where specimens, raw data and the final report are storedArchive recordsArchive statement
(14)The statement signed by the quality assurance unitQuality assuranceFront matter

The last two columns are our reading and a common pattern. The rule names neither sources nor sections.

Only two of the 14 required items are the study director's own writing

The 14 items in 21 CFR 58.185(a), by where each one starts

Facility and test article records: 6 itemsThe approved protocol: 4 itemsWritten from the data by the study director: 2 itemsOther people's signed documents: 2 items
14items
  • Facility and test article records6 items
  • The approved protocol4 items
  • Written from the data by the study director2 items
  • Other people's signed documents2 items

Our reading of the sources 2 · Our classification of the rule's list. Items 2, 3, 7 and 8 start in the protocol; items 9 and 11 are the study director's.

Show the numbers
PartValue
Facility and test article records6 items
The approved protocol4 items
Written from the data by the study director2 items
Other people's signed documents2 items

What the protocol has to carry before the report can

Those four items are only as good as the plan. 21 CFR 58.120 requires an approved written protocol listing, among other things, the purpose, the test system, each dosage level, the type and frequency of tests, the records to be kept and the proposed statistical methods. Any change "shall be documented, signed by the study director, dated, and maintained with the protocol".9 A protocol amendment that nobody carried into the report is one way for the report to disagree with the file.

What the report leaves out by design

Writers sometimes ask how much to reproduce. A report summarizes, and the raw data stays in the archive. OECD asks for "a summary of results" and "all information and data required by the study plan".4 FDA's IND rule separately asks for "a full tabulation of data suitable for detailed review" for each toxicology study meant to support a clinical trial, so a report headed for an IND may carry individual animal tables as appendices.10

03 · The rules and their dates

FDA Part 58, EPA and OECD GLP: what each says about the final report, November 2026

In shortFDA's Part 58 dates from December 1978 and OECD's Principles from 1997, and the report paragraphs have barely moved. FDA's 2016 rewrite is still only a proposal. The two rulebooks agree on most things and differ on vocabulary, on what the QA statement says and on where the compliance statement lives.

The report rules are old, and the proposed rewrite has waited since 2016
  1. Dec 22, 1978FDA Part 58

    Final rule published, 43 FR 59986.

  2. Sep 4, 1987Part 58 amended

    The last change to 58.185's text.

  3. Nov 26, 1997OECD Principles revised

    Adopted by the OECD Council.

  4. Aug 24, 2016FDA proposes a rewrite

    81 FR 58341. No final rule found.

  5. Sep 20, 2021OECD No. 22

    Advisory document on GLP data integrity.

  6. Apr 30, 2026FDA paperwork notice

    Asks for comment on renewing the current Part 58 records, hours unchanged.

Source 2,4,11,6,12,13

Show the numbers
WhenWhat
Dec 22, 1978FDA Part 58
Sep 4, 1987Part 58 amended
Nov 26, 1997OECD Principles revised
Aug 24, 2016FDA proposes a rewrite
Sep 20, 2021OECD No. 22
Apr 30, 2026FDA paperwork notice
Feb 4, 2027IND wording rule

Protocol or study plan, test article or test item: FDA and OECD side by side

PointFDA, 21 CFR Part 58OECD Principles of GLP
The plan is calledProtocol9Study plan4
The substance is calledTest article2Test item4
Who signs the report"Signed and dated by the study director"2Study director, "to indicate acceptance of responsibility for the validity of the data"4
Compliance statementNo such statement in 58.185. The sponsor files one with the IND under 312.23(a)(8)(iii)10In the report: "the extent of compliance with these Principles" should be indicated4
QA statement saysDates of inspections, and of findings reported to management and the study director3Types and dates of inspections and phases inspected, and it "would also serve to confirm that the final report reflects the raw data"4
Specialists' reportsSigned and dated, and part of the final report2"Signed and dated by them", named in the report4
CorrectionsAn amendment that identifies the part and the reason, signed and dated by the person responsible2Amendments with the reason, signed and dated by the study director4
Reformatting for a filingNot addressed in 58.185"Does not constitute a correction, addition or amendment"4

FDA's own comparison page, current April 7, 2015, sets these texts side by side with EPA's GLP rules for pesticides and chemicals. EPA's text says that modifying a final report to meet EPA's submission requirements is no correction, addition or amendment.14

Other rulebooks follow the same pattern. In the European Union, Directives 2004/9/EC and 2004/10/EC apply. National authorities inspect the test facilities, and the European Medicines Agency (EMA) coordinates these inspections for studies in its centralized procedure.15 The UK has its own 1999 regulations.16 Swiss authorities report that the EU is evaluating its GLP Directive in a 2025 to 2026 project. We found no published outcome.17 A report written to both FDA and OECD can take the stricter reading of each row above.

What the 2016 proposal would change, and has not. FDA proposed a GLP quality system with new terms such as "contributing scientist", and a sponsor statement in every submission. We found no final rule on November 3, 2026. FDA's April 30, 2026 paperwork notice still describes the current regulation. The proposal is useful for one thing today: its preamble records FDA's view on merged reports, quoted in section 5.6,12
04 · Raw data and its copies

Why a number in a GLP report has to lead back to an original record, through every copy

In shortFDA defines raw data by what the report needs: the original records "necessary for the reconstruction and evaluation" of it. Between that record and a sentence, a number may pass through a balance file, a system export, a spreadsheet, a table and a summary. Each copy is a place to go wrong, and each needs an owner. Decide in writing what your facility treats as raw data before you trace anything to it.

FDA defines raw data as worksheets, records, notes "or exact copies thereof" that result from original observations. It can include "recorded data from automated instruments" and computer media.8 OECD says "original test facility records and documentation, or verified copies".4 Both let a copy stand in for an original, and both require that it really is one.

That carries a trap for anyone tracing a report to a spreadsheet. In its 1981 questions and answers, FDA was asked whether a computer printout derived from data transferred to computer media from laboratory data sheets is raw data. The answer was "No."5

Of computerized data-acquisition systems that meet its criteria, the same document says "either the magnetic media or hardcopy printouts are considered to be raw data". It also says that if raw data are transcribed and sent to a sponsor for formatting, QA should assure the computer-formatted data accurately reflect them.5

So tracing a report number to an export cell proves the report matches the export. Showing the export matches the original record takes a further step, and your procedures have to say who takes it.

One food weight takes five forms on its way to a conclusion
  1. 1Original record

    The balance reading and who took it, recorded directly and promptly.

    TechnicianRaw data
  2. 2System export

    A file from the data system, delivered with the package.

    Data system or data managerRaw data only if a verified copy
  3. 3Report table

    A group mean, with precision set by the template.

    Report writerSummary
  4. 4Results sentence

    The mean, a difference from control, a marker of significance.

    Report writer or study directorSummary
  5. 5Summary and conclusion

    The same value repeated, then judged.

    Study directorInterpretation

Our reading of the sources 8,18,11 · Our sketch of a common path. Facilities differ on where raw data ends, and should write down their own answer.

Show the numbers
StepWhat happensWhoTime
Original recordThe balance reading and who took it, recorded directly and promptly.TechnicianRaw data
System exportA file from the data system, delivered with the package.Data system or data managerRaw data only if a verified copy
Report tableA group mean, with precision set by the template.Report writerSummary
Results sentenceThe mean, a difference from control, a marker of significance.Report writer or study directorSummary
Summary and conclusionThe same value repeated, then judged.Study directorInterpretation

The ALCOA words behind a traceable GLP number

Data integrity guidance across regulated work rests on the letters ALCOA: attributable, legible, contemporaneous, original and accurate. The UK regulator, the MHRA, adds that the "+" sometimes used refers to complete, consistent, enduring and available, and says there is "no difference in expectations".19 OECD's advisory document on GLP data integrity applies the same thinking to studies. For a report writer, three clauses matter most:

Changes keep the old value

Part 58 says a change must not obscure the original entry, must give the reason and must be dated and identified.18 A corrected export is a new version beside the first.

Copying is the risk

OECD: "Transcriptions should be avoided as they increase the risks of errors and inconsistencies." If unavoidable, "verified by a second person or operated by a validated system".11

Excluded data stays

OECD: "All data (even if invalidated) should be retained with the data set and be available for review."11 See section 7.

How long the records behind a final report are kept

Part 58 ties retention to the filing: at least two years after a marketing application is approved, at least five years after results are submitted in support of an application, or at least two years after the study ends if it is never submitted, whichever is shortest.20 Records go to an indexed archive with a named person responsible. The report must say where they are.2,20 Other authorities set their own periods, so a global program plans for the longest it faces.

05 · Who signs what, and in what order

Contributor reports, QA statement, compliance statement and study director signature: what each signature stands for

In shortA GLP report carries several signatures, and people mix them up. Specialists sign their own reports. Quality assurance signs a statement about its inspections. The study director signs the final report and accepts responsibility for the data. Each signature means something different, and a change after signing has to be made as an amendment.

Four signatures sit around a final report, and the study director's comes after QA's audit
  1. 1Contributors sign

    Pathology, toxicokinetics and other specialist reports, each signed and dated.

    Contributing scientistsBefore the report can rest on them
  2. 2Draft released to audit

    The draft report and data go to quality assurance.

    Study directorHouse procedure
  3. 3QA audits and reports

    Report compared with raw data. Findings go to the study director and management.

    Quality assuranceIndependent of the study
  4. 4QA signs its statement

    Inspection dates and reporting dates, with nothing left open that needs a further audit.

    Quality assuranceIncluded with the report
  5. 5Study director signs

    Signed and dated. The extent of GLP compliance is indicated.

    Study directorThe final report
  6. 6Amendments, if any

    Part, reason, signature, date. QA reviews it too.

    Study director, QAAfter signing

Our reading of the sources 2,3,4 · The rules fix the content of each signature. The exact order is set by your procedures; OECD's QA document assumes QA's statement reflects the report as issued.

Show the numbers
StepWhat happensWhoTime
Contributors signPathology, toxicokinetics and other specialist reports, each signed and dated.Contributing scientistsBefore the report can rest on them
Draft released to auditThe draft report and data go to quality assurance.Study directorHouse procedure
QA audits and reportsReport compared with raw data. Findings go to the study director and management.Quality assuranceIndependent of the study
QA signs its statementInspection dates and reporting dates, with nothing left open that needs a further audit.Quality assuranceIncluded with the report
Study director signsSigned and dated. The extent of GLP compliance is indicated.Study directorThe final report
Amendments, if anyPart, reason, signature, date. QA reviews it too.Study director, QAAfter signing
SignatureWhoWhat it saysWhat it does not cover
Contributor reportEach scientist or specialistThis part of the work is accurately reported by the person who did it2,4The whole study
QA statementQuality assurance unit, separate from the study3When inspections were made and findings reported. Under OECD, it also confirms the report reflects the raw data4FDA: "The QAU is not expected to perform a scientific evaluation of a study"5
Study director's signatureThe study directorOECD: responsibility "for the validity of the data". OECD's study director document adds "a complete, true and accurate representation"4Anything after signing. FDA allows a deputy during leave, identified in the study records5
GLP compliance statementStudy director under OECD; sponsor to FDA under 312.2310,4How far the study followed GLP, or why it did notWhether the findings are right

Why FDA keeps specialists' reports separate from the integrated report

When FDA asked for comments on modernizing Part 58, many respondents suggested one integrated final report in place of the individual scientists' reports. In its 2016 proposal FDA recalled that individual reports exist "to ensure the findings of the individual scientists are accurately reflected", said merged reports "would obscure the individual scientist's accountability" and wrote: "We continue to affirm these statements." In the same passage it said: "we support processes used for the efficient review of the draft study report."6 Faster drafting fits that. Removing the contributor's signed report does not.

What a QA audit of the final report looks for, in OECD's words

OECD's consensus document on quality assurance lists five questions for the report audit:

  1. Plan and procedures. Was the study carried out under them?
  2. Accuracy. Is it "accurately and completely reported"?
  3. Elements. Does it have all the elements GLP requires?
  4. Consistency. Is it "internally consistent"?
  5. Raw data. Are the raw data complete?

QA must be told of all changes made during the audit. Before signing, it should confirm that "no changes to the report have been made which would require a further audit".4

QA is never the author. FDA requires the unit to be "entirely separate from and independent of the personnel engaged in the direction and conduct of that study".3 So a report checker that QA runs on its own is a QA tool. A checker the study team runs before the audit is the study team's tool, and QA still does its own review.

Draft, audited draft and final: what each is good for at FDA

FDA's 1995 guidance on Phase 1 INDs accepts an integrated summary built on "unaudited draft toxicologic reports", with final, "fully quality-assured" reports available on request within 120 days of the start of the human study.21 GLP still applies in full, and a draft can be read by regulators, so its labeling and version control matter from the first release.

06 · One number, many places

Keeping a toxicology report consistent: a percent change and a mean, worked through

In short"Internally consistent" sounds simple until you count the places a value appears. A calculated figure also depends on which inputs and which rounding you used, and two honest people can get different answers. The rule asks you to describe your calculations. Writing the rounding rule down, and calculating one way, prevents most arguments.

A weight gain that appears in three sections of the report

In the fictional study, mean male body weight gain from Day 1 to Day 29 is 142.7 g in the top dose group and 156.8 g in controls. Those two values sit in one spreadsheet row. The difference is:

(142.7 − 156.8) ÷ 156.8 = −8.99%, reported as −9.0%

That figure appears in the results, in the summary and in the conclusion. If a later correction changes 142.7, all three have to change, as well as the table, any table legend and any later summary a sponsor has built on it.

Two honest answers to the same difference in food consumption

Now take the four-week mean of food consumption. The weekly values for the top dose group are 24.6, 25.1, 25.7 and 25.9, and for controls 25.8, 26.4, 26.9 and 27.1 grams per animal per day.

StepTop dose groupControlsDifference
Mean of the four weekly values, unrounded25.32526.55−4.6%
Mean rounded to one decimal first, as the sheet shows25.326.6−4.9%

Fictional example, our arithmetic. The screens in Part B show 25.3, 26.6 and −4.9%, calculated from the two displayed cells.

Neither figure is a mistake, and neither changes what the study found. The trouble comes when the table uses one method and the text the other, or when a QA auditor recalculates with a calculator and gets a different answer from the report. 58.185(a)(11) requires "a description of the transformations, calculations, or operations performed on the data".2 Say in the methods whether percent changes come from displayed or stored values, and apply that everywhere.

A final report has more ways to disagree with itself than with its raw data

Which consistency check catches which kind of slip

RarelySometimesUsuallyNearly always
Against raw dataTable against textText against summaryAgainst the planTyped digit in a tableNearly alwaysUsuallyRarelyRarelyA sentence left behind after a correctionSometimesNearly alwaysNearly alwaysRarelyRounding or percent method mixedSometimesNearly alwaysUsuallyRarelyWrong animal count or group sizeUsuallySometimesSometimesNearly alwaysPlan change not carried into the reportRarelyRarelyRarelyNearly alwaysLate contributor report not folded inSometimesSometimesUsuallyUsually

Our reading of the sources 2,4,22 · Our judgment from the rule text and QA's audit questions, offered as a way to design your checks. Nobody has published these rates.

Show the numbers
Against raw dataTable against textText against summaryAgainst the plan
Typed digit in a tableNearly alwaysUsuallyRarelyRarely
A sentence left behind after a correctionSometimesNearly alwaysNearly alwaysRarely
Rounding or percent method mixedSometimesNearly alwaysUsuallyRarely
Wrong animal count or group sizeUsuallySometimesSometimesNearly always
Plan change not carried into the reportRarelyRarelyRarelyNearly always
Late contributor report not folded inSometimesSometimesUsuallyUsually

Words that have to stay the same from table to conclusion

Consistency reaches past digits. Pathology terms should match across the contributor report, the table and the text. INHAND, a joint naming project of toxicologic pathology societies, offers one shared vocabulary, and its organizers have worked with FDA and the standards body CDISC to bring its terms into SEND, the data standard described in section 11.23 Group names, dose labels, day numbering and units all drift. A report that writes "Day 29" in one table and "Week 4" in another for the same time point is a question QA will ask.

When a report is translated, every check runs again

FDA's drug center has presented a case in which English translations of final study reports did not accurately reflect the raw data: misspellings, omitted paragraphs or amended reports, mislabeled parameters, wrong tables and formatting errors. Some translated versions carried the study director's name printed by the translator. The compliance statement in one translation named different regulations from the original.24 A translation is one more copy, and it needs its own control.

07 · Blanks, exclusions and deviations

What a GLP report says about a missing value, an excluded value and a plan deviation

In shortA number nobody recorded has to stay absent from the report, and the report says so. An excluded value stays on file with a documented reason. Anything that may have affected the data's quality has to be described. Writing these down costs a sentence. Leaving them out is what FDA cites.

Four things you can do with an empty cell in a data export, and one you never do

SituationWhat the report doesWho decidesRecord needed
The value exists, but the file did not transferUses the value from a corrected, versioned exportData owner supplies it; study director acceptsBoth versions kept, with who and when18
The value was never recordedStates "not recorded" and leaves it out of any mean, with the group size notedStudy directorA note to the study file; describe in the report if it may affect the data2
The value was recorded but is invalidExcludes it and says whyStudy director, under rules set in advance where possible11The justification, and the value retained11
Required data is still with a specialistWaits, or goes forward with the conclusion marked pendingStudy director and the specialistThe plan clause and the request
Fill it from last week or a similar groupNeverNobodyQA has to confirm results "accurately reflect the raw data", and this number has no raw data behind it3

OECD's data integrity document is plain about exclusions: data may only be invalidated "where it can be demonstrated through sound scientific or technical justification or logical sense that the data are not representative of the recorded event". For common cases, "the rules to exclude or invalidate data should be defined in advance in the study plan or in SOPs".11

Deviations and unforeseen events: FDA's item (9) in practice

Item (9) of the report list asks for "all circumstances that may have affected the quality or integrity of the data". The word "may" makes this wider than confirmed problems, and it is one of the items FDA cites by number.2,25 The report is the last link: if nobody noted a problem when it happened, nobody can describe it later. 58.33(c) puts the duty on the study director to see that such circumstances "are noted when they occur".7

Two lines to write in every deviation. What happened, with the date and the records. Then the study director's assessment of its effect on the study, because OECD asks them to "assess and document the impact of any deviations".4 "This did not affect the interpretation" needs a reason a reader can check.
08 · The conclusion is a judgment

NOAEL and adversity in a study report: words the study director has to own

In shortMost of a report describes. The conclusion decides. Calling a finding adverse, and naming a no-observed-adverse-effect level, are judgments made and signed by people. This guide treats them only as report content: what the text should show, who writes it, and what stays out of a draft until they have.

The no-observed-adverse-effect level, or NOAEL, is, in plain words, the highest dose tested at which the study's scientists find no adverse effect, compared with the control group. The Society of Toxicologic Pathology's Adversity Working Group calls for it to be set "at the level of the overall study report".26 How a sponsor then uses that figure belongs to other documents and other people, and this guide does not cover it.

The same working group published best-practice recommendations for reporting adversity. In its words: "Adverse is a term indicating 'harm' to the test animal", "Test article-related effects should be described on their own merits", and decisions "to consider them as adverse or nonadverse should be justified".26 For a report writer, that gives a structure: first describe each change, with its group, sex, direction and size. Then give the reasoning. Then, separately and in the study director's name, the call.

How a draft should carry a conclusion that is not yet decided

Described first

Each change stands with its numbers. A reader can disagree with the call and still use the report.

Marked as proposed

A draft conclusion says it is proposed, and what it waits for, such as a contributor report still to come.

Changed visibly

If later data changes the wording, the summary and conclusion change together, and the version history shows it.

Signed by a person

The "interpretation, analysis, documentation and reporting of results" belong to the study director.7

A contributor's findings can arrive after the first draft, as the recovery pathology does in this guide's example. A conclusion written before those findings are signed is a draft of a draft, and the report should say so.

09 · What inspectors cite

FDA GLP inspection findings: where the final report itself gets cited

In shortFDA finalized 44 GLP inspections in fiscal 2024, and in a separate review of 37 inspections, 17 ended with a Form 483. Several recurring items concern the report: deviations left out, circumstances not described, corrections made outside an amendment. Three warning letters show what that looks like in a real file.

44

GLP inspections finally classified by FDA in fiscal 2024, up from 29 in fiscal 2023. This counts by classification date, across all centers.27

FDA BIMO metrics
17 of 37

GLP inspections reviewed for fiscal 2024 ended with a Form FDA 483, the list of observations an investigator leaves at the end.22

FDA 483 trends, FY 2024
0

of the fiscal 2024 GLP classifications were Official Action Indicated, the most serious of three. Twenty-two were Voluntary and 22 needed no action.27

FDA BIMO metrics
Classified GLP inspections rose to 44 in fiscal 2024, from 16 in fiscal 2021

FDA GLP inspections, domestic and foreign, final classified, by fiscal year

33 inspectionsFY2020
16 inspectionsFY2021
33 inspectionsFY2022
29 inspectionsFY2023
44 inspectionsFY2024

Source 27 · Remote regulatory assessments are counted separately. CDER's share in FY2024 was 23.

Show the numbers
PeriodValue
FY202033 inspections
FY202116 inspections
FY202233 inspections
FY202329 inspections
FY202444 inspections
Half of fiscal 2024's GLP inspections needed voluntary action

Inspection outcomes by fiscal year: no action, voluntary action, official action

No action indicatedVoluntary action indicatedOfficial action indicated
FY20202094
FY2021124
FY20222193
FY202316103
FY20242222

Source 27

Show the numbers
No action indicatedVoluntary action indicatedOfficial action indicated
FY20202094
FY20211240
FY20222193
FY202316103
FY202422220

What FDA's FY2024 483 review lists under the study director

FDA sorted its fiscal 2024 GLP citations into four themes: testing facility management, the study director, standard operating procedures and training. It published the themes without counts on its charts. Under the study director theme, three of the nine listed items are about the report:22

Deviations missing

FDA: failure to assure that protocol deviations are included in the final report.

Circumstances missing

"The final study report did not include a description of all circumstances that may have affected the quality or integrity of the data."

Corrections outside an amendment

"Corrections or revisions to the study report were not made in the form of an amendment."

Final reports in three FDA warning letters, 2023 to 2026

LetterWhat FDA said about the reportThe lesson for report writers
Lovelace Biomedical Research Institute, October 6, 202628Under 58.35(b)(6), QA's duty to review the report: "For 20 out of 34 animals, the final study report did not include all the abnormal cageside clinical observations". A second protocol's report had the same gap for "all 48 animals". The first report also left out descriptions of "dosing issues". FDA said the revised reports "did not completely address the individual dosing issues".Comparing a report with its data is QA's duty under 58.35(b)(6). FDA read the revised reports as well.
Vedic Lifesciences Pvt. Ltd., March 9, 202629Reports "did not accurately identify the testing facility", did not name the correct study directors, and the people who signed them "were not involved in the conduct of these studies". Storage locations were also wrong.Items 1, 10, 13 and the signature are facts, and FDA checks them.
SAMM Solutions dba BTS Research, October 20, 202325Cites 58.185(a)(9) for a report that "did not include a description of all circumstances", beside the study director's failure to authorize deviations and QA's failure to confirm the results.An event not recorded when it happens cannot reach the report.

The same findings at EPA and FDA's veterinary center

EPA's January 2026 update lists its 2025 inspection findings under the reporting subpart: names missing from final reports, "miscalculation and misreporting", and "final report does not reflect raw data". It explains why that matters: "EPA reviewers only see derived data in the final report. Reviewers make their regulatory decision based on the submitted final report."1 FDA's veterinary center put the same item first in its 2023 list of top findings in GLP and clinical studies, and listed two more on documents: amended reports that do not clearly say what changed and why, and a QA inspection of the final report missing from the QA statement.30

The worst outcome is disqualification. FDA may disqualify a testing facility when noncompliance "adversely affected the validity of the nonclinical laboratory studies" and lesser actions will not do.31 Short of that, a finding costs time: a written response, a revised report and a study director pulled from other work.

Omissions are harder to see than wrong digits, and cost more to fix late
How much rework it causes once found →
Hidden and expensive: check these first
Visible and expensive
Hidden and cheap
Visible and cheap
Observations left outDeviation not describedCorrection outside an amendmentWrong facility or namesMixed roundingTyped digit
How easy a reader finds it in the report →

Our reading of the sources 22,28,1 · Our judgment, offered as a starting point for a risk-based check list. It holds no published rates.

Show the numbers
ItemHow easy a reader finds it in the report (0–1)How much rework it causes once found (0–1)
Observations left out0.200.75
Deviation not described0.150.60
Correction outside an amendment0.550.70
Wrong facility or names0.700.55
Mixed rounding0.250.25
Typed digit0.600.30
10 · How often copying goes wrong

Transcription error rates: what is measured, and what it means for a toxicology report

In shortNo one has published an error rate for GLP report writing. The nearest careful measure comes from clinical data entry: about one field in 300 wrong before checking, and a check that catches between 40% and 88%, depending on the method and on who runs it. Treat that as a reason to measure your own rate.

In a Japanese kidney transplant registry, two operators keyed 560 forms, and checks found errors in 358 of 104,720 fields, a rate of 0.34%. In reading aloud, one operator reads the keyed data and another compares it with the form. The researchers compared two versions of that with two versions of double entry, each run by the same operator or a different one.32

A check by a different operator catches far more than one by the same operator

Share of single-entry errors detected, by verification method

Double entry, different operator88.3%
Double entry, same operator69%
Reading aloud, different operator59.5%
Reading aloud, same operator39.9%

Source 32 · Clinical registry data, 2003. Report writing may behave differently.

Show the numbers
MethodErrors detected
Double entry, different operator88.3%
Double entry, same operator69%
Reading aloud, different operator59.5%
Reading aloud, same operator39.9%

What those rates would mean on a 400-number report, worked through

Take an illustrative report with 400 hand-copied numbers and borrow the registry's rate. That rate may not transfer, so replace it with your own.

400 numbers × 0.34% ≈ 1.4 slips before checking
1.4 × (1 − 0.883) ≈ 0.16 left after an independent check
1.4 × (1 − 0.399) ≈ 0.8 left after a read-aloud check by the same operator

At 4,000 numbers, the arithmetic gives about 14 slips before checking, and 1.6 or 8.2 left. These figures are illustrative. Copying a known figure into a table may be easier or harder than keying a form, and a tired reader at the end of a long report may do worse. The reasonable conclusions are narrower: slips are expected in a long report, the kind of check matters as much as whether one happened, and the weakest check measured left about 60% of the slips in place.

The better check costs more. The same study reports 74.8 hours for double entry against 57.9 hours for reading aloud, on the same forms.32 Across a long report, the second reader's hours add up.

What we could not find. We found no public figure for transcription errors per GLP report, QA findings per report across the industry, or the share of 483 observations traced to report text. Your QA unit's own records of report audits will tell you more than any published number.
11 · SEND and the report

SEND datasets and the study report: FDA expects them to agree, from the draft onward

In shortFor many toxicology studies, FDA also wants the data in a standard electronic form called SEND. It goes in with the PDF report, including a draft. So a modern study has two presentations of the same results, made by different hands, and a reviewer can compare them. Differences have to be explained in a short guide written for the reviewer.

The Standard for Exchange of Nonclinical Data, or SEND, is a format for submitting study data to FDA. FDA's Study Data Technical Conformance Guide, version 6.3 of October 2026, is nonbinding but specific:33

QuestionWhat FDA's guide says
When is it sent?"At the same time as the nonclinical PDF study report for a commercial IND or NDA/BLA"
Does a draft report count?Yes. "SEND datasets are required when submitting a draft study report", under the dates in FDA's catalog
Does status change it?Draft, interim or final "does not impact whether the SEND requirement applies"
Is it only for GLP studies?"The requirement for SEND is not limited to GLP studies"
What must agree?Results in the report and the datasets should "be traceable back to the original data collected", and the datasets "can be summarized for meaningful group comparison aligned with the study report"
When they differ?The nonclinical Study Data Reviewer's Guide should mention differences that stop incidence tables being "easily reconciled"
When the report goes final?Resubmit only if data changed. An updated reviewer's guide is recommended either way, with the current report version. "This information also applies to amended study reports"

So every change to a report needs one more question: does this change the datasets, or the reviewer's guide? A correction made late in the report and forgotten in the SEND package gives a reviewer two answers. Appendix I of the guide asks for a data submission "consistent with the study report", and the people who create the datasets are often not the people who write the text.33

Research has reached the same seam from the other side. In 2026, authors at one large drug company described a pipeline that reads existing toxicology reports and turns them into structured data aligned with SEND terms. Testing on 200 of their own reports, they found sensitivity "typically above 95%" and precision "frequently exceeding 97%" for histopathology, organ weight and NOAEL-related endpoints, with weaker results on route and substance identifiers, which they tie to uneven reporting habits. All authors are current or past employees of that company.34 The study reads reports. Searching PubMed and the web on November 3, 2026, we found no published test of the opposite job: drafting a GLP report from study data.

12 · AI rules for GLP reports

AI in toxicology report writing: what FDA, EMA and the EU say as of November 2026

In shortNo regulator has written a rule for AI drafting of GLP reports. The existing rules still apply to whoever signs and to the systems used. FDA's AI draft leaves out drafting that does not affect the reliability of results, EMA says your procedures extend to AI in non-clinical studies, and the European GMP draft on AI does not reach GLP. Keep the record and the signature with people.

Most AI rules reach a GLP report only indirectly, and the GLP rules reach it fully

How directly each text bears on drafting a GLP final report, as we read it

NoIndirectlyIn partYes
Reaches the report's recordsReaches the tool or systemFinal text in force, November 202621 CFR Part 58YesIndirectlyYesOECD No. 17 and No. 22YesYesYes21 CFR Part 11YesYesYesFDA AI draft, January 2025IndirectlyIndirectlyNoEMA reflection paper, 2024IndirectlyIn partYesFDA and EMA principles, 2026IndirectlyIndirectlyYesEU AI Act, after the OmnibusNoIndirectlyIn partDraft EU GMP Annex 22NoNoNoFDA CSA guidance, 2026NoNoYes

Our reading of the sources 2,11,35,36,37,38,39,40,41,42 · Our reading, so check it with your own counsel and QA. Details below.

Show the numbers
Reaches the report's recordsReaches the tool or systemFinal text in force, November 2026
21 CFR Part 58YesIndirectlyYes
OECD No. 17 and No. 22YesYesYes
21 CFR Part 11YesYesYes
FDA AI draft, January 2025IndirectlyIndirectlyNo
EMA reflection paper, 2024IndirectlyIn partYes
FDA and EMA principles, 2026IndirectlyIndirectlyYes
EU AI Act, after the OmnibusNoIndirectlyIn part
Draft EU GMP Annex 22NoNoNo
FDA CSA guidance, 2026NoNoYes
TextStatus, November 2026What it means for report drafting
FDA, AI to support regulatory decision-making37Draft, January 2025It does not address AI for "drafting/writing a regulatory submission" where that does "not impact patient safety, drug quality, or the reliability of results from a nonclinical or clinical study". A tool that calculates or selects reported values is harder to place there.
EMA reflection paper, section 2.3.238Final, September 9, 2024"Existing Standard Operating Procedures (SOPs) would be expected to extend to all AI/ML applications in non-clinical studies." OECD No. 17 and No. 22 "should be considered".
FDA and EMA guiding principles39Published January 14, 2026Shared principles for AI across drug development, with no rule on study reports.
OECD No. 17 and No. 2211,35In use; 2016 and 2021Test facility management owns a risk-based validation approach; transcription must be avoided or verified. Written before generative AI, and still the GLP text that applies.
21 CFR Part 1136In forceSignature shows name, date and time and meaning, linked to its record. A signer is a person. Your firm validates systems for "consistent intended performance".
EU AI Act40AI Omnibus in force July 27, 2026; Annex III rules from December 2, 2027; Annex I from August 2, 2028We read a report-drafting tool as outside the high-risk lists. Confirm this with your counsel.
Draft EU GMP Annex 2241Draft; EudraLex lists none on November 3, 2026Covers GMP, so it does not reach GLP reports. Its draft says generative AI "should not be used in critical GMP applications"; EMA's 2026 workshop report says wider scope has been discussed, with no revised text published. Some QA teams will read this as a signal.
FDA Computer Software Assurance42Final, February 2026Scoped to medical device production and quality system software, so it does not cover GLP reports.

Three limits on AI drafting that follow from the GLP rules

A model cannot be a study director, because the rule names a scientist.7 A model's number cannot stand as a result unless someone can reach the record behind it.8 And checking a model's text with the model is weak: OECD asks for a second person or a validated system, and a person has to be able to see what was checked.11
13 · Time and money, as published

How long a GLP report takes: FDA's paperwork estimate, and what nobody publishes

In shortLittle is published. FDA's paperwork estimate puts reporting at about 27.65 hours per response, and half a million hours a year across sponsors. It is a planning number. No public survey times a report from data received to signature, so the useful number is your own.

FDA estimates about 500,000 hours a year for GLP final reports alone

Estimated hours a year in FDA's April 2026 notice, selected Part 58 lines

58.185 Final reports499,774 hours
58.195 Retaining records294,255 hours
58.35 QA records272,926 hours
58.120 Protocols150,878 hours
58.35(b)(7) QA statements18,075 hours

Source 12 · 300 respondents, 60.25 reports each, 18,075 a year. FDA made no adjustment to its previous estimate.

Show the numbers
Part 58 lineHours a year
58.185 Final reports499,774 hours
58.195 Retaining records294,255 hours
58.35 QA records272,926 hours
58.120 Protocols150,878 hours
58.35(b)(7) QA statements18,075 hours

The notice's averages are worth reading closely: 27.65 hours per final report, one hour per QA statement, and 32.7 hours per protocol record.12 An hour for the statement is plausible because the statement itself lists dates; the audit behind it is counted elsewhere. For the report, 27.65 hours is an average over everything from short tests to long studies, and it is an estimate made for paperwork purposes. It is no benchmark for a repeat-dose study.

One public contract shows why a late draft hurts a laboratory's cash

In one public 2006 contract, 40% of the price waited on the draft report

Payment schedule in one GLP toxicology study agreement

At study startOn draft reportOn final report, or eight weeks after the draft
Share of the price, %50%40%10%

Source 43 · One contract from 2006, shown as an example of the mechanism and no benchmark.

Show the numbers
At study startOn draft reportOn final report, or eight weeks after the draft
Share of the price, %50%40%10%

Report dates also touch a sponsor's calendar. Tufts researchers put a day of delay at about $40,000 in direct trial cost, and at about $500,000 in lost sales in their journal article and about $800,000 in their white paper, all from one dataset of 645 drugs.44 Those figures describe trials in Phase II and III. A study report sits earlier, and it costs a day only when a filing is waiting on it, so use them with that limit in mind.

What we could not find. We found no public figure for days from data received to a signed report, cost per report, QA findings per report, the number of GLP reports written worldwide beyond FDA's estimate, or the market for report writing. Vendors quote their own percentages without saying which clock they stopped. Date two events on your next six studies, package complete and report signed, and you will have better evidence than this page.
14 · How teams assemble a report today

Who assembles a GLP report today: study director, contributors, technician, report writer and QA

In shortA study director sits at the center of a small group, and may carry several studies at once. In the fictional sample team, five of 11.2 days go to re-keying and cross-checking numbers that already exist; we found no public figure for a real team. Laboratories write in house, a contract laboratory writes for its sponsor, and software fills in parts of the work.

From study director to archivist: who touches a GLP final report

SD

Study director

The single point of control. Reads the draft against the data, writes or approves the interpretation, signs. May carry several studies.7

Cares about: seeing where a number came from without opening twelve spreadsheets.
CS

Contributing scientists

Pathologist, clinical pathologist, toxicokinetics scientist and others. Each signs their own report, which becomes part of the final report.2

Cares about: their findings arriving in the report as they wrote them.
ST

Study technician or data manager

Owns the in-life records and answers data queries when a value looks wrong.

Cares about: being asked for one exact value, with no guess made in the meantime.
RW

Report writer or coordinator

In larger groups, builds tables and first-draft text and chases everyone. In smaller ones, the study director does this too.

Cares about: fewer rounds spent re-keying tables.
QA

Quality assurance auditor

Independent of the study. Audits the report against raw data and signs the statement. FDA says QA should examine and correlate the raw data records.3,5

Cares about: a record of what was compared, so the audit can be reconstructed.4
TF

Test facility management and archivist

Management appoints the study director and answers for resources and validated systems. The archivist holds the records.20,35

Cares about: study directors' time, and records that can be found.

Six hand-offs between a data package and a signed GLP report

A GLP report changes hands six times in the sample team's 11.2 days

Times shown are the fictional sample team's estimates, 11.2 working days in all

  1. 1Package checked against the plan

    Are all the required tables and signed reports here?

    Report writer or study director1 day
  2. 2Tables re-keyed

    Every table built from the export by hand.

    Report writer3 days
  3. 3Results, summary, conclusion

    Written around the tables.

    Study director, writer3 days
  4. 4Numbers cross-checked

    Every number against the export.

    A second person2 days
  5. 5Missing data chased

    Technician, pathologist, data manager.

    Study director1 day
  6. 6Review and sign the draft

    Then QA's audit starts.

    Study director1.2 days

Fictional example from this guide · From the solution's fictional sample team. No public figure exists for this. Replace them with your own.

Show the numbers
StepWhat happensWhoTime
Package checked against the planAre all the required tables and signed reports here?Report writer or study director1 day
Tables re-keyedEvery table built from the export by hand.Report writer3 days
Results, summary, conclusionWritten around the tables.Study director, writer3 days
Numbers cross-checkedEvery number against the export.A second person2 days
Missing data chasedTechnician, pathologist, data manager.Study director1 day
Review and sign the draftThen QA's audit starts.Study director1.2 days

Where a repeat-dose report's working days go

Five of the sample team's 11.2 days go on moving and checking numbers

Working days from data received to a signed draft, by hand, fictional sample team

Checking the package, chasing missing dataRe-keying tablesWritingCross-checking numbersReview and signature
Days2 days3 days3 days2 days1.2 days

Fictional example from this guide · An estimated split. Your team's will differ.

Show the numbers
Checking the package, chasing missing dataRe-keying tablesWritingCross-checking numbersReview and signature
Days2 days3 days3 days2 days1.2 days

In house, at a contract laboratory or with software: five ways GLP reports get written today

WayHow it worksStrengthWeak point
In-house study groupA sponsor's or laboratory's own study directors and writers, a Word template and spreadsheetsControl and study knowledgePeaks, and hand copying
Contract laboratoryThe laboratory's study director signs; the sponsor reviews drafts, usually over several roundsCapacity and GLP systemsSponsor comments can cross with late data
Study data system reportsTables generated inside the system that collected the dataTables come straight from the dataText, contributor reports and data from other systems stay manual
General AI assistantsA person pastes data and asks for textQuick first wordsNo link from a number to its record, and a validation problem
Report-specific softwareReads the plan, data and template, drafts with links to sourceDrafts with each number tracedNew to QA; needs validation for your use and a pilot
Part B · See it working

Botminds Preclinical Study Report Automation on one 28-day toxicity report

Part A described the work without naming a product. This part shows how Botminds does it, on VLT-TOX-028, the fictional study from the top of the page. Every person, study, number and document in the screens is sample data, and the findings appear only as what the sample report says.

15 · One report, start to finish

The VLT-TOX-028 draft: 156 numbers traced, one blank left empty and recovery data still to come

In shortThis is the example from the top of the page, inside the product. Six AI agents, each a program with one job, read the signed plan, the export and the template, and draft the report overnight. Dr. Lena Ortiz, the study director, reads it beside the export. A blank and a missing report stop her signature until the people who hold those records supply them. She signs; the agents never do.

1

Each number in the draft joined to its cell in the data export

The data package arrives on October 5, with study plan v2.0 and its amendment, the data exports, a signed toxicokinetics report and repeat-dose template v5.2. On the morning of October 6, the agents have drafted nine sections. The header reads 156 traced, 1 blank, 2 gaps and 3 of 9 sections approved.

Lena points at 142.7 g in Section 4.2. The sheet behind it opens at BW_Males, cell E7 lights, and a line joins the two. Below, the screen names the file, the sheet and the three sections that use this value: 1, 4.2 and 5. The export is locked and read-only.

The draft beside its data. Every number is a chip. Pointing at one opens its sheet and lights its cell.
2

A percent change lights both of the cells it comes from

The −9.0% is calculated, so it lights two cells: E7 and B7. The footer shows the working, (142.7 − 156.8) ÷ 156.8. If QA recalculates this figure, it can see at once which inputs the report used.

This is the question from section 6. On screen, percent changes in the sample use the displayed cells, and your house rule decides which you want.

A percent change and its cells. The calculation, both inputs and every section that uses them.
3

The Week 4 cell is empty, so the sentence says so

Cell E5 of FC_Males has no value. The sentence reads "not in raw data", and no four-week mean is stated. The screen names the evidence: empty in the export of October 5, weighing logged on September 12 by Ana Kowalski, balance file not transferred.

The Blanks and gaps view lists this next to a second blocker. Study plan section 9.4 requires microscopic examination of the recovery groups, and that file is not in the package. A minor item asks Lena to confirm one excluded weighing, recorded as spilled.

A red blank. No estimate and no carry-forward. Signature stays blocked while this is open.
Blanks and gaps. Each item carries its evidence and plan clause, says whether it blocks signature, and names who to ask. Section 9.4 here is the sample plan's own text.
4

One request, and the blank becomes a number from a corrected file

Lena clicks "Ask Ana Kowalski". Ana sends VLT-TOX-028_FC_v2.xlsx, signed and versioned, and the first export stays on the record. Week 4 is 25.9. The section is redrafted with a mean of 25.3 against 26.6 g/animal/day in controls (−4.9%), and the consistency checker finds 0 mismatches.

Lena confirms the exclusion of the spilled weighing, and a note appears under the table: which cage, which week, why, and the date of the raw data note. That is the record OECD asks for on excluded data.11

Asking for the value. Each step is shown and kept on the record.
Filled from source. The header now reads 0 blank. The sheet shows the corrected export, dated October 6.
The exclusion, stated. The study director's confirmation adds the note to the results.
5

Recovery pathology arrives, and three sections are redrafted

Section 4.5 shows the gap, and the draft conclusion says plainly what it waits for: "Reversibility is not yet shown". Before the recovery data, the NOAEL reads "proposed", in Section 5.

Lena requests the data from Dr. Omar Haddad, the study pathologist. MI_Recovery.xlsx arrives for 20 animals, signed by him. Sections 4.5, 1 and 5 are redrafted, and the header rises to 166 traced numbers. The conclusion's wording is still Lena's to accept or change. The section drafter proposes adversity and the NOAEL and marks them for her.

Marked as proposed. The draft conclusion says what it waits for, in highlighted words.
Recovery findings. The new paragraph and its numbers come from the pathologist's signed file.
The conclusion, updated. Marked "to review". Signing is still ahead.
6

She signs with a stated meaning, and the draft goes to QA

The dialog shows what she is signing: study report version 1.0, nine sections, 166 numbers traced, no open blanks or gaps, and a warning that six sections are not yet marked as reviewed. She enters her password and chooses a meaning. The fields follow 21 CFR 11.50 and 11.70: printed name, date and time, meaning, and a link to this exact version.36

The sample uses the meaning "release to Quality Assurance for audit", and the draft goes to Dr. Maya Chen. So read this signature as the study director's release of the draft. The page stamp reads "FINAL V1.0", yet QA has not audited this version, so it marks the release of a draft. The GLP final report signature under 58.185(b) belongs after QA's audit, on the report QA's statement describes, and the same dialog offers "final report" and "report amendment" as separate meanings. Your procedures decide the order.2,3,4

Sign the report. The version, the signer, the meaning and the password. Only the study director signs.
A draft released to QA, stamped "FINAL V1.0". Name, date, time and meaning sit on the page. The meaning is release to QA for audit, so read this stamp as the release of a draft. QA's audit has not happened yet, and the final report signature comes after it.

The solution's design targets are 1.4 days from data received to a signed draft, 100% of numbers linked to a data cell with none estimated, and 0.3 transcription findings per report at QA audit. They are targets, to be measured in the live solution and on your own studies. The fictional team's by-hand baselines are about 11 days and 4.6 findings. The sample study's own numbers are the ones on these screens.

16 · Every other screen

Number trace, data package, studies list and rules: the rest of the report writing screens

In shortOne study is the story. These screens show how the same discipline runs across a team: the trace an auditor can download, the package checked against the plan, every blank across studies, a genetic toxicology report waiting on a historical range, and the settings a QA lead would ask about.

Number trace. All 156 numbers in the first draft with their sources, by section. It can be downloaded for QA.
A section with a gap. She can request the data, or add a statement that it is pending.
The package against the plan. Ten requirements and 3,842 values mapped to their clauses and files. Two are not complete, and each row names who to ask. FC is the sample's own label for food consumption; SEND's code for it is FW.45
Requesting recovery data. The same pattern as a blank, shown step by step.
History. People and agents on one list, each step timed.
Blanks across studies. Three open, eight closed in 30 days: six filled from source, two stated by a study director, none estimated.
Another report type. In this genetic toxicology report the historical range is missing from the package, so it stays blank and is not quoted from an old report. Row labels are shortened on this screen.
Studies. Twelve sample reports by stage: repeat-dose, genetic toxicology, reproductive toxicology and others, each to its own template.
Drafting, step by step. Each agent's step is on the record while the draft is built.
A results section. Clinical pathology, reviewed by a contributing scientist before the study director.
Export. Word or PDF, the trace in Excel, and the trace and gap list as appendices. The statements' places are in the template; QA writes and signs its own.
Dashboard. Sample figures across a fictional team. Draft time (3.6 hours) is the agents' writing alone, and turnaround runs from data received to a signed draft.
Where the time goes now. Most of what remains is the study director's review. These are sample figures.
Your template and signers. Template, number style, pathology terms, who reviews and who signs.
Rules. Two cannot be switched off: leave a missing value blank, and re-check every number against its source before signature.

Select any screen to open it larger. The study, people and figures are fictional sample data. Rule text, section numbers and dose labels on the screens are the sample's own; for the real clauses, see Part A.

Results sections 4.2, 4.3 and 4.5 hold almost two-thirds of the draft's 156 numbers

Numbers traced per section of the first VLT-TOX-028 draft

4.2 Body weight and food33 numbers
4.5 Histopathology33 numbers
4.3 Clinical pathology32 numbers
3 Methods19 numbers
1 Summary12 numbers
4.4 Organ weights10 numbers
4.1 Mortality and observations9 numbers
2 Introduction5 numbers
5 Conclusion3 numbers

Fictional example from this guide

Show the numbers
SectionNumbers
4.2 Body weight and food33 numbers
4.5 Histopathology33 numbers
4.3 Clinical pathology32 numbers
3 Methods19 numbers
1 Summary12 numbers
4.4 Organ weights10 numbers
4.1 Mortality and observations9 numbers
2 Introduction5 numbers
5 Conclusion3 numbers
Missing required data and empty cells make up most of what the sample team caught before QA

37 blanks and gaps across the fictional team's last 90 days

Missing data the plan requires: 12Value not in the data, left blank: 11Number differs from the plan: 6Deviation not described: 5Unit or format mismatch: 3
37caught
  • Missing data the plan requires12
  • Value not in the data, left blank11
  • Number differs from the plan6
  • Deviation not described5
  • Unit or format mismatch3

Fictional example from this guide

Show the numbers
PartValue
Missing data the plan requires12
Value not in the data, left blank11
Number differs from the plan6
Deviation not described5
Unit or format mismatch3
17 · Who signs, what goes in and out

Six report agents, one study director and the systems a GLP report draws on

In shortEach agent has one job and a line it cannot cross. People decide what the report concludes and sign it: contributors review their sections, the study director signs the report, and QA audits on its own and signs its own statement. The solution reads the files you already make and hands back a report in your template.

From study plan reader to consistency checker: the six report agents

Study plan reader

Reads the signed plan and every signed amendment: design, groups, endpoints, time points, dates and the sections the template needs.

Never infers a design element the plan does not state. Flags an unsigned amendment.

Raw data reader

Loads every table in the package, maps it to its kind of data, and checks counts and groups against the plan.

Never changes a value in a file. Records every excluded value with its reason.

Table builder

Builds report tables cell by cell from the source tables, with significance markers, under your house style.

Never types a number, or rounds beyond your style.

Section drafter

Writes each section in house style, describing changes by group and sex, with every number as a link to its cell.

Never fills an empty cell, and never decides adversity or the NOAEL. It proposes them for the study director.

Gap finder

Compares what the plan requires with what the package holds, and lists missing files, empty cells, unsigned contributor reports and exclusions.

Never closes a gap itself. Quotes the plan clause and data evidence for each.

Consistency checker

Re-reads every number against its cell, and checks that summary and conclusion repeat the results and that percent changes come from the cited cells.

Never lets a mismatch through to signature.

Who signs a VLT-TOX-028 report, and under which control

PersonDecides or signsThe control around it
Dr. Lena Ortiz, study directorApproves sections, fills or states each blank, accepts adversity and NOAEL wording, signsPassword and stated meaning, linked to the exact version, and kept in the audit trail
Dr. Omar Haddad, study pathologistReleases his signed data and reviews histopathology firstThe report's histopathology section is routed to him by a setting
Ana Kowalski, study technicianSends a corrected, versioned exportThe first export stays on the record
Dr. Maya Chen, Quality AssuranceAudits against the data and signs her own statementReceives the trace and the gap list; the audit stays hers, separate from the study team3

The agents' work supports the people who answer for the report. Controls such as roles, versioning and an audit trail support your compliance with 21 CFR Part 58, OECD GLP and Part 11. Whether a system is validated for your use is your facility's determination, on your procedures.35 Botminds' own credentials are SOC 2 Type II audited and information security managed to ISO 27001.

From signed plan and export to a report with its trace

From the study

  • Signed study plan and amendments
  • Data export: body weight, food, clinical signs, clinical pathology, organ weights, macroscopic and microscopic findings
  • Contributing scientists' signed reports, such as toxicokinetics and pathology

From your reporting group

  • Report templates by study type and your house style
  • Number style and significance markers
  • Reviewers, signers, QA auditor and who answers data queries
Agents read, draft, link and re-check Each number linked to its cell, in your template under your rules
People decide and sign
Every number linked to its cell

What the study director gets back

  • Draft study report in your template, Word or PDF
  • Number-to-source trace: file, sheet and cell
  • List of blanks and gaps, each with evidence and how it closed
  • Signed draft released to Quality Assurance

What changes for study directors and writers

  • Sections to read and edit, and no tables to key
  • A data query that names the cell and the record
  • Time spent on what the findings mean

Fits the study systems and quality records you already run

The solution works from what a study already produces: study data system and laboratory system exports, spreadsheets, signed PDFs and Word templates. Those systems stay where they are, and their records remain the records. It serves large programs with many concurrent studies, with roles and separation of duties, maker and checker on each section, and a trace and history you can export for audit.

The design target moves the keying and checking days, and keeps review with people

Estimated working days per report, the fictional team by hand against the design target

By hand, sample teamWith the solution, design target
Reading the plan, checking the package1 day0.05 days
Re-keying tables3 days0.02 days
Writing results, summary, conclusion3 days0.03 days
Cross-checking numbers2 days0.1 days
Chasing missing data1 day0.5 days
Study director review and signature1.2 days0.7 days

Fictional example from this guide · The by-hand total is the sample's 11.2 days and the target is 1.4 days. An estimated split in the solution's data, measured in the live solution and on your studies. QA's audit is outside this clock.

Show the numbers
By hand, sample teamWith the solution, design target
Reading the plan, checking the package1 day0.05 days
Re-keying tables3 days0.02 days
Writing results, summary, conclusion3 days0.03 days
Cross-checking numbers2 days0.1 days
Chasing missing data1 day0.5 days
Study director review and signature1.2 days0.7 days
Part C · Are you ready to automate?

Automating GLP final report writing: today's cost, your return, your readiness and a twelve-week pilot

You direct studies, audit them, run a study reporting group, or pay for the reports a filing depends on. This part is written for you: what errors and delays cost, what automating GLP report writing could return, whether your facility is ready, and what to ask any vendor, including us.

18 · What errors and delays cost

What hand-keyed tables and late drafts cost your study directors and QA unit

In shortStart from your own studies. We found no published figure for what a GLP report costs or how many errors one carries, so the numbers that matter are in your timesheets, QA audit records and study calendars. A few published figures frame them.

27.65 hours

per final report in FDA's paperwork estimate, across all study types, for 18,075 reports a year. Set your own hours beside it.12

FDA notice, April 2026
0.34%

of fields keyed wrongly before checking, in a clinical registry. It is the nearest careful measure we found, and it comes from different work.32

Kawado et al., 2003
46%

of the 37 GLP inspections FDA reviewed for fiscal 2024 ended with a Form 483. Not all of those observations concern reports.22

FDA, FY 2024
A team's own baseline is what a design target gets measured against

The fictional sample team against the solution's design targets

Sample team, by handDesign target
Working days, data received to signed draft11.21.4
Transcription findings per report at QA audit4.60.3

Fictional example from this guide · Neither is a measurement of your team, and neither has been measured by anyone outside the solution's sample data.

Show the numbers
Sample team, by handDesign target
Working days, data received to signed draft11.21.4
Transcription findings per report at QA audit4.60.3
What we could not find. We found no public figure for cost per GLP report, hours per report by study type, transcription findings per report, or how often a late draft moves a filing. Vendors rarely say which clock they stopped. Measure your own.

Pulling a baseline from your last six study reports

CostWhere it hidesHow to find your number in a week
Hours keying and checking tablesReport writers' and study directors' general timeTimesheets for six comparable reports, or ask two people to estimate from their last report
Package complete to signed draftNobody dates "package complete"Dates from email and the document system, for six studies
Data queriesTechnicians' and data managers' inboxesCount queries per report on the last three, and days until answered
QA findings on numbersQA's audit reports, sorted by study rather than kindTag findings on your last six audits: transcription, wording, missing content
Sponsor review roundsComment files on shared drivesRounds per report; ask three sponsors or monitors what took longest
Amendments after signingThe archiveCount amended reports in two years, and read the reasons

The study report costs that no timesheet shows

The study director's attentionHours checking digits are hours away from thinking about findings and other studies.
The invoice that waitsIn one public contract, 40% of the price fell due on the draft report.43
The IND that waitsA sponsor's calendar can stop at one report, and SEND has to travel with it.33
Inspection timeFDA's October 2026 letter on omissions in final reports came after the reports were revised, and asks for a written reply within 15 business days.28
Trust in the signatureA study director who has signed a wrong number reads every later report differently.
19 · Your return

What GLP report automation returns once you count keying, checks and data queries

In shortPut in your own numbers. The calculator values two things you can measure: hours per report and the hours QA findings cost. Calendar value appears on its own line and stays out of the total, because it counts only when something is waiting on the report. Every default is an assumption to replace.

Keying, number checks and queries: where report hours come back

Keying

Tables arrive built from source

A person reviews a table, and stops typing it.

reports × hours saved keying × hourly cost
Number checks

Comparison by machine, judgment by people

The second reader looks at what was flagged and what the sentence claims.

reports × checking hours saved × hourly cost
Data queries

One exact question

A query that names the cell and quotes the plan clause needs one reply.

queries × hours saved per query × hourly cost
QA findings

Fewer rounds on transcription

QA's time goes to methods, deviations and completeness.

reports × findings avoided × hours per finding × hourly cost
Amendments

Fewer corrections after signing

Counts only reports you would otherwise have to amend, and audit again.

amendments avoided × hours per amendment × hourly cost
Calendar

Days off the filing

Counts only where a filing or a payment waits on the report, priced by whoever owns it.

days earlier × value of a day

Work out your return from reports a year, hours per report and QA findings

Every input marked illustrative is an assumption. Ninety hours is close to the fictional team's 11.2 days at eight hours; FDA's paperwork estimate is 27.65 hours per report across all study types,12 so try that too. The findings defaults are the fictional team's baseline and the solution's design target.

Your volume
Hours per report, up to the signed draft
Transcription findings at QA audit
Your cost, and the calendar
Illustrative yearly value
Report and finding time today, valued$0
Time released, valued$0
After your yearly cost$0
Hours released a year0
Reports a year to cover your cost0
Value of earlier days, kept out of the total$0

Formulas, per year:
Time today = reports × (hours today + findings today × hours per finding) × hourly cost
Time released = reports × (hours saved + findings avoided × hours per finding) × hourly cost
After your cost = time released − yearly cost
Break-even reports = yearly cost ÷ (hours saved per report, findings included × hourly cost)
Earlier days = reports waited on × days earlier × value of a day

Hours saved per report decide how many reports a year pay back the tool

Reports a year to cover $150,000 of yearly cost, at $95 an hour

Saves 60 hours a report27 reports
Saves 25 hours a report64 reports
Saves 10 hours a report158 reports

Illustrative · replace with your own numbers · Rounded up to whole reports.

Show the numbers
Hours saved per report, findings includedReports a year
Saves 60 hours a report27 reports
Saves 25 hours a report64 reports
Saves 10 hours a report158 reports

At these defaults, a group writing 40 reports a year pays for the tool on hours alone. A group whose reports look more like FDA's 27.65-hour average may save too little per report, and should work that out first. Short reports with few tables gain less per report than repeat-dose studies full of them.

Start here20 · Readiness check

How ready your study reporting group is: raw data, templates, QA and study director sign-off

In shortPick the answer closest to your group today. Eight questions score 0 to 2, and the last is for reflection. The meter adds up your score as you go, and each question says why it matters and what a strong answer sounds like.

1
Reports a year

How many GLP or GLP-like study reports does your group write or oversee in a year?

Why it mattersVolume turns hours per report into capacity. FDA's estimate averages about 60 reports per respondent a year.12
A strong answer"About 40, of which a dozen are repeat-dose with recovery groups."
2
Your baseline

Do you know your days from package complete to signed draft, and your hours per report?

Why it mattersNo public benchmark exists, so only your own history can prove an improvement.
A strong answer"Six reports timed: 13 working days on average, about 110 hours, two data queries each."
3
What counts as raw data

Has your facility written down, for each data system, whether an export is raw data, a verified copy or a working file?

Why it mattersA trace to an export proves only what the export holds. FDA's 1981 answer on transferred data makes this a real question.5
A strong answer"Yes, in our data management procedure, with the system's verification records behind it."
4
Your templates and house style

Are your report templates written down, versioned and mapped to the 14 items in 58.185 and to OECD section 9?

Why it mattersA template that hides an item hides it faster once drafting is automated.2,4
A strong answer"One template per study type with an owner, and a mapping table reviewed by QA last year."
5
Number rules

Do you have a written rule for rounding, percent changes and significance markers that every report follows?

Why it mattersSection 6 shows two honest answers to one difference. Software will apply whichever rule you give it.
A strong answer"Yes: stored values, one decimal, in the template's methods text."
6
QA's view

Has your QA unit said how it would audit a report with a source trace, and what it would still check by hand?

Why it mattersQA stays independent and audits on its own terms. If it will not use the trace, part of your return disappears.3
A strong answer"QA will sample the trace, re-check critical numbers and treat methods and deviations as before."
7
Computerized systems

Does your test facility have a working process for validating a new system for GLP use, with roles and a risk-based approach?

Why it mattersOECD gives this to test facility management. A vendor can supply controls and evidence, and the determination stays yours.35
A strong answer"Yes, with a plan template that already covers AI features and change control."
8
An owner and a budget

Is someone senior ready to own this across study directors, QA and IT, with money for a pilot?

Why it mattersA tool used by one study director stays that person's habit, and different templates multiply.
A strong answer"The head of study reporting owns it; QA and IT have agreed a 12-week pilot."
9
Vision · for reflection

If an inspector pointed at one number in a report signed two years ago, what would have to be true for you to show its original record in five minutes?

Why it mattersYour answer lists the gaps: naming, archives, versions and the link between a report and its records. Each is a candidate job for software or for your own procedures.

Three readiness bands: settle your raw data, replay a closed study, or plan the rollout

0–6

Explore

Pull numbers from your last six reports, write down what each system's export is, settle one template per study type and name an owner. Start narrow, for example with a package check against the plan.

7–11

Ready to pilot

Replay one closed study, plant errors in a copy of its export, and run one live report in parallel with your people signing everything. Count catches, false alarms and hours.

12–16

Ready to implement

Plan your templates, rules and sign-off owners as settings, validation for your use, roles and separation of duties, connections to your study data systems, and rollout study type by study type.

21 · Questions for any vendor

What to ask a toxicology report software vendor about cells, blanks, contributors and signatures

In shortAsk every vendor the same questions, us included. The answers show how a draft is built: whether a number can exist without a source, what happens when a cell is empty, whether contributors keep their own reports, who signs what, and how you would measure it on your own study.

AskA good answerA warning sign
Numbers and their sources
Can any number appear in the draft without a link to its cell?No, and you can see the link and its file version"The model is very accurate"
Does a percent change show both inputs and the rule?Yes, under your rounding ruleOnly the result is shown
How is a number checked: by a fixed comparison or by asking another model?A fixed comparison, with the evidence shownA second AI says the sentence looks right
Blanks, exclusions and missing data
What happens to an empty cell?It stays blank, names the record and blocks signature, and that rule cannot be switched offImputation, or a smoothing option
How is an excluded value shown?The reason, who confirmed it, and the value kept on file11The row simply disappears
Contributors and study director
Do individual scientists' signed reports stay as they are?Yes, attached and quoted accurately, with unsigned ones flagged6"One integrated report replaces them"
Who decides adversity and the NOAEL?The study director, with any proposal marked as oneThe tool's conclusion is the default text, unmarked
QA, signatures and amendments
What does QA get, and can it work independently of the study team's tool?An exportable trace and read-only access, with QA's audit left to QAQA and authors share the same checker settings
How is a signature bound to a version? What does its meaning say?Name, time and meaning, linked to the version.36 Separate meanings for release to audit, final and amendmentOne "approved" button
How does it handle an amendment after the final signature?The part, the reason and a new signature, kept beside the original2The old file is overwritten
Records, validation and AI limits
What evidence do you supply for our validation?Controls, test evidence and change notices, with the determination left to you35"Our product is GLP certified" or "Part 11 validated"
What credentials do you actually hold?Named audits you can read, such as SOC 2 Type II and ISO 27001 for information securityA logo with no report behind it
When the model changes, what happens to our reports?Notice, re-test on your set, and a record of the version used in each draftSilent updates
Do our study data train your models?No, in writing, and it is in the contract"Only in anonymized form"
Does it help keep the report and SEND package in agreement?A clear answer on what it reads, and what stays with your SEND team33"SEND-ready" with no detail
22 · How to start

A twelve-week GLP report pilot: replay a signed study with planted faults, run one live report, then decide

In shortStart with a study whose report is already signed, so you know the right answers. Plant errors in a copy of its export, run the tool and count what it finds. Then run one live study in parallel, with your own process still responsible for the record. The plan below covers one study type in twelve weeks.

A twelve-week pilot ends with a decision on four numbers
Your teamVendor
Baseline from six reports; choose a study type
QA's position and a validation plan for your use
Load your template, style and rules
Replay a closed study with planted faults
Score the replay
Parallel run on one live report
Decide
Week 04812

Illustrative · replace with your own numbers

Show the numbers
ActivityFromTo
Baseline from six reports; choose a study type02
QA's position and a validation plan for your use14
Load your template, style and rules24
Replay a closed study with planted faults46
Score the replay67
Parallel run on one live report611
Decide1112

Catch rate, false alarms, hours and QA findings for each planted fault

MeasureHowWhat a good result looks like
Catch ratePlant 20 faults in a copy: changed digits, an empty cell, a missing contributor signature, a plan amendment not carried, a wrong countEvery one flagged, with evidence. Agree the number with QA first
False alarmsFlags a person rejects, per reportFew enough that people still read them
Hours to a signed draftTimesheets against your baseline, reading and editing includedYour own threshold from the calculator
QA findings by kindParallel report against the same audit methodTranscription findings fall, and other kinds do not rise
The full working-session questions: twelve questions in four groups

Bring study directors, a contributing scientist, QA, the data manager and IT into one room.

A

Study mix and data sources

  • Which study types make up most of your hours, and which would you start with?
  • Which systems feed a report, and which values still live on paper or in private spreadsheets?
  • What is your written answer on whether each export is raw data?
B

Templates and number rules

  • Does each template map to the 14 items and OECD section 9?
  • What is your rounding and percent rule, and where is it written?
  • How are pathology terms kept the same from contributor report to text?
C

Quality assurance and signatures

  • What would QA still check by hand, and what would it sample?
  • What are the meanings of each signature in your procedure, and in what order?
  • Which version does QA's statement describe, and how do you know nothing changed since?
D

Validation, sponsors and SEND

  • Who owns validation for your use, and how do model updates reach change control?
  • What must a sponsor see or approve before a tool is used on its study?
  • Who checks report and SEND package against each other, and when?
23 · Questions people ask

GLP final report FAQ: the 14 items, signatures, QA, amendments, SEND and AI drafting

In shortThe questions people search for most, each answered on its own.

What does 21 CFR 58.185 require in a GLP final report?

Under 21 CFR 58.185 it must include 14 items, among them the facility and dates, objectives and procedures with protocol changes, statistical methods, test and control articles, the test system, dosing, all circumstances that may have affected data quality, names, a summary and conclusions, signed reports of individual scientists, storage locations and the QA statement. OECD section 9 lists a similar set and asks the report to state the extent of GLP compliance. Neither sets section numbers or an order.

Who signs a GLP study report?

The study director signs and dates the final report. Individual scientists sign their own contributed reports, and quality assurance signs its own statement. Under OECD, the study director's signature indicates acceptance of responsibility for the validity of the data and the extent of GLP compliance.

What is the difference between a QA statement and a GLP compliance statement?

The QA statement comes from quality assurance and gives inspection dates and when findings were reported; under OECD it also confirms the report reflects the raw data. The compliance statement says how far the study followed GLP. Under OECD it is in the report, from the study director; for an FDA IND, the sponsor provides one under 21 CFR 312.23(a)(8)(iii).

How do you correct a signed GLP report?

With an amendment. Under 21 CFR 58.185(c) it clearly identifies the part added to or corrected and the reasons, and it is signed and dated by the person responsible. OECD's text asks the same of the study director. FDA's 1981 questions and answers say QA reviews amendments as well.

Is a data export raw data under GLP?

It depends on how it was made. 21 CFR 58.3(k) covers exact copies and data recorded by automated instruments, while FDA's 1981 answers say a printout derived from data transferred from laboratory sheets to computer media is not raw data. Each facility should write down what its exports are, and keep the verification behind any copy it treats as raw data.

How long does it take to write a toxicology study report?

No public survey measures it. FDA's April 2026 paperwork estimate averages 27.65 hours per final report across study types. The fictional team in this guide takes about 11 days from data received to a signed draft on a 28-day study, and your own figure depends on the study and the template. Date "package complete" and "signed" on six reports to get a real number.

What do you do when a value is missing from the raw data?

Ask whoever holds the original record. If the value exists, use a corrected, versioned file and keep the first one. If it was never recorded, state that in the report and describe it if it may have affected the data, because 21 CFR 58.185(a)(9) asks for that. Never fill it from another week or group.

What does FDA most often cite about GLP final reports?

FDA's fiscal 2024 trends list protocol deviations missing from the final report, circumstances affecting data quality not described, and corrections not made as an amendment. Its October 2026 letter to one research institute cited QA for final reports that left out observations and dosing issues. FDA's fiscal 2024 charts give themes without counts, so no ranking is published for report items alone.

Are SEND datasets required with a GLP report?

For many toxicology studies supporting a commercial IND or an NDA or BLA, yes. FDA's Study Data Technical Conformance Guide says they go in at the same time as the PDF report, including a draft report, and that the requirement does not depend on GLP status. The results should be traceable and aligned with the report, and differences go in the nonclinical Study Data Reviewer's Guide.

Can AI write a GLP study report?

AI can draft text and tables, and we found no rule that forbids it, but we also found no published test of drafting a GLP report from study data. The study director stays responsible for the report, numbers still have to lead back to raw data, and EMA expects your procedures to extend to AI in non-clinical studies. Treat AI output as a draft, and validate the system for your use.

Does GLP report software make a report compliant?

No software can do that. Compliance is a property of the study and the facility, decided by how they follow Part 58 or OECD's Principles. Software can supply controls, such as version control, an audit trail and signature fields that support your compliance, and your test facility validates it for your use.

What is a NOAEL in a study report?

The no-observed-adverse-effect level is, in plain words, the highest dose tested at which the study's scientists find no adverse effect, compared with the control group. In a report it is a judgment that the study director states and justifies. A toxicologic pathology working group recommends describing each effect on its own merits first, and setting the level in the overall study report.

Must a toxicology report be final before it supports an IND?

No. FDA's 1995 Phase 1 guidance accepts an integrated summary based on unaudited draft toxicology reports, with final, fully quality-assured reports available on request within 120 days of the start of the human study and an update for any differences. SEND goes with a draft too. Good labeling and version control therefore matter from the first release.

24 · One-page summary

The GLP report method, the November 2026 rules and 14 report terms, on one page

Print this page

In shortThe whole guide on one screen: the method, the rules as of November 2026, the readiness scale and the terms.

The method
  1. Check the package against the signed plan and amendments before drafting anything.
  2. Write down what each export is, and trace every number to a file, a sheet and a cell.
  3. Leave an empty value empty. Fill it from the record, or state it. Keep excluded values on file.
  4. Keep one rule for rounding and percent changes, and describe it in the methods.
  5. Describe each change first, then the judgment, in the study director's name.
  6. Keep contributors' signed reports whole. Release to QA, close its findings, sign, archive. Correct only by amendment.

Readiness: score 0–2 on eight questions: 0–6 explore · 7–11 pilot · 12–16 implement.

As of November 2026: 21 CFR 58.185 last amended 1987; FDA's 2016 proposal not final · OECD Principles from 1997, No. 22 from 2021; EU reviewing its GLP Directive · SEND with the PDF report, draft included (guide v6.3, October 2026) · FDA's AI guidance still a draft · draft EU GMP Annex 22 does not reach GLP · EU AI Act Annex III rules from December 2, 2027 · IND wording rule effective February 4, 2027 unless withdrawn.

14 terms
GLP
Good Laboratory Practice: record and organization rules for nonclinical studies.
Final report
The signed report of one study, 21 CFR 58.185 or OECD section 9.
Study director
The single point of study control, who signs the final report.
Protocol, study plan
FDA's and OECD's names for the approved written plan.
Test article, test item
FDA's and OECD's names for what is being tested.
Raw data
Original records or exact copies, needed to reconstruct the report.
Contributor report
A specialist's signed report, part of the final report.
QA unit
The group, independent of the study, that inspects and audits it.
QA statement
QA's signed list of inspection and reporting dates.
Amendment
A signed correction or addition to a final report.
Form 483
The observations an FDA investigator leaves after an inspection.
NOAEL
No-observed-adverse-effect level: a judgment stated in the report.
SEND
The standard format for submitting nonclinical study data to FDA.
ALCOA
Attributable, legible, contemporaneous, original, accurate.
25 · Sources

Sources

Accessed November 2026. Regulatory status statements are as of November 2026.

  1. US EPA, Good Laboratory Practice Program Regulatory Update, presentation to the National Alliance of Independent Crop Consultants, January 28, 2026, 2025 inspection findings. naicc.org
  2. 21 CFR 58.185, Reporting of nonclinical laboratory study results, CFR 2025 edition (revised as of April 1, 2025). govinfo.gov
  3. 21 CFR 58.35, Quality assurance unit, CFR 2025 edition. govinfo.gov
  4. OECD, Good Laboratory Practice: OECD Principles and Guidance for Compliance Monitoring, 2005. Holds the Principles adopted by Council on November 26, 1997, and the consensus documents on quality assurance and on the study director. oecd.org
  5. FDA, Guidance for Industry, Good Laboratory Practices Questions and Answers, June 1981, minor editorial changes December 1999 and July 2007. fda.gov
  6. FDA, Good Laboratory Practice for Nonclinical Laboratory Studies, proposed rule, 81 FR 58341, August 24, 2016, docket FDA-2010-N-0548. No final rule found on November 3, 2026. govinfo.gov
  7. 21 CFR 58.33, Study director, CFR 2025 edition. govinfo.gov
  8. 21 CFR 58.3, Definitions, paragraph (k), raw data, CFR 2025 edition. govinfo.gov
  9. 21 CFR 58.120, Protocol, CFR 2025 edition. govinfo.gov
  10. 21 CFR 312.23(a)(8), IND content and format, pharmacology and toxicology information, CFR 2025 edition. govinfo.gov
  11. OECD, Series on Principles of GLP No. 22, Advisory Document on GLP Data Integrity, ENV/CBC/MONO(2021)26, September 20, 2021, sections 6.7 and 6.8, as published by Germany's GLP authority. bfr.bund.de
  12. FDA, Agency Information Collection Activities; Proposed Collection; Comment Request; Good Laboratory Practice Requirements for Nonclinical Laboratory Studies, notice, FR Doc. 2026-08371, docket FDA-2026-N-3532, scheduled for April 30, 2026, Tables 1 and 2. federalregister.gov
  13. FDA, Nonclinical Testing Terminology, direct final rule, FR Doc. 2026-19350, docket FDA-2026-N-5347, scheduled for September 22, 2026. federalregister.gov
  14. FDA, Records and Reports, comparison of FDA, EPA and OECD text, content current April 7, 2015. fda.gov
  15. EMA, Good laboratory practice compliance page: Directives 2004/9/EC and 2004/10/EC; inspections by the competent authority. ema.europa.eu
  16. UK, The Good Laboratory Practice Regulations 1999, S.I. 1999/3106. legislation.gov.uk
  17. Swiss Federal Office of Public Health, GLP Newsletter 2025, and GLP Newsletter 2024 on the OECD Council act. admin.ch
  18. 21 CFR 58.130, Conduct of a nonclinical laboratory study, paragraph (e), CFR 2025 edition. govinfo.gov
  19. MHRA, GXP Data Integrity Guidance and Definitions, March 2018, sections 3.10 and 6.11. gov.uk
  20. 21 CFR 58.190 and 58.195, storage and retention of records, CFR 2025 edition. govinfo.gov
  21. FDA, Content and Format of Investigational New Drug Applications (INDs) for Phase 1 Studies, guidance, November 1995. fda.gov
  22. FDA, FY 2024 Good Laboratory Practice FDA 483 Observation Trends. fda.gov
  23. British Society of Toxicological Pathology, INHAND page. bstp.org.uk
  24. Lanning and Chen, FDA CDER, Good Laboratory Practice (GLP) Case Studies, presentation, 2022, Case 2 on translated reports. fda.gov
  25. FDA, warning letter to SAMM Solutions, Inc. dba BTS Research, October 20, 2023. fda.gov
  26. Kerlin et al., Recommended ("Best") Practices for Determining, Communicating, and Using Adverse Effect Data from Nonclinical Studies, Toxicol Pathol 44(2):147-62, 2016. PMID 26704930. pubmed.ncbi.nlm.nih.gov
  27. FDA, Bioresearch Monitoring Inspections, Fiscal Year 2024 Metrics, GLP slides. fda.gov
  28. FDA, warning letter to Lovelace Biomedical Research Institute, October 6, 2026. fda.gov
  29. FDA, warning letter to Vedic Lifesciences Pvt. Ltd., March 9, 2026. fda.gov
  30. FDA Center for Veterinary Medicine, QASR Hot Topics, presentation, March 16, 2023, top findings in studies. fda.gov
  31. 21 CFR 58.202, Grounds for disqualification, CFR 2025 edition. govinfo.gov
  32. Kawado et al., A comparison of error detection rates between the reading aloud method and the double data entry method, Control Clin Trials 24(5):560-9, 2003. PMID 14500053. pubmed.ncbi.nlm.nih.gov
  33. FDA, Study Data Technical Conformance Guide, version 6.3, October 2026, sections on the nonclinical reviewer's guide, SEND scope and resubmission, Appendix I. Nonbinding. fda.gov
  34. Doktorova et al., Transforming animal study toxicology reports into structured, harmonized data using large language models, Arch Toxicol 100(9):4105-4134, 2026. PMID 42133063. pubmed.ncbi.nlm.nih.gov
  35. OECD, Series on Principles of GLP No. 17, Application of GLP Principles to Computerised Systems, 2016, paragraphs 12 and 22 to 27, as published by Germany's GLP authority. bfr.bund.de
  36. 21 CFR 11.10, 11.50 and 11.70, electronic records and signatures, CFR 2025 edition. govinfo.gov
  37. FDA, Considerations for the Use of Artificial Intelligence to Support Regulatory Decision-Making for Drug and Biological Products, draft guidance, January 2025. fda.gov
  38. EMA, Reflection paper on the use of Artificial Intelligence in the medicinal product lifecycle, EMA/CHMP/CVMP/83833/2023, September 9, 2024, section 2.3.2. ema.europa.eu
  39. FDA and EMA, Guiding Principles of Good AI Practice in Drug Development, content current January 14, 2026. fda.gov
  40. European Commission, AI Act page, on the AI Omnibus, Regulation (EU) 2026/1744, in force July 27, 2026; Annex III rules December 2, 2027; Annex I rules August 2, 2028. ec.europa.eu
  41. European Commission and PIC/S, draft EU GMP Annex 22, consultation July 7 to October 7, 2025. EudraLex Volume 4 listed no Annex 22 on November 3, 2026. EMA report EMA/156789/2026 on the June 30, 2026 workshop. picscheme.org
  42. FDA, Computer Software Assurance for Production and Quality Management System Software, final guidance, February 2026. fda.gov
  43. A GLP toxicology study agreement dated October 18, 2006, filed as an exhibit with the US Securities and Exchange Commission. One contract, used only for its payment schedule. sec.gov
  44. Smith, DiMasi and Getz, Tufts CSDD, journal article in Ther Innov Regul Sci 58(5):855-862, 2024 (PMID 38773058), and white paper, Quantifying the Value of a Day of Delay in Drug Development, August 2024. csdd.tufts.edu
  45. SAS Clinical Standards Toolkit documentation, list of SEND 3.0 domains: FW is Food and Water Consumption. Read in place of the CDISC implementation guide, whose page does not list its domains. support.sas.com
Next step

See it on your own study data packages.

Explore the solution, or bring one closed study's signed plan, data export, contributor reports and template, and we will draft from them with you, every number linked to its cell and every empty cell left blank for your study director.