09:17 to 09:47: one sour gas line, from the wall to the owner’s desk
A refinery’s three-yearly mechanical integrity audit is under way, with 26 days left to sign. This is one morning of it, as the audit team saw it.
demoThe refinery, its staff and its numbers are sample data.
- 01Before 09:17
24,316 inspection records on one wall, and 437 of them gray
Lead process safety auditorThree years of inspections, one square per record: piping, vessels, relief devices, safety instruments, pumps and tanks, a column per unit. 437 records could not be read, so they stay gray and count in each result. 12 of 15 tests are already closed by a second person. Class 1 thickness is still open, and the panel offers it next.
- 0209:17
Class 1 piping in plain words: 1,181 passed, 17 failed, 8 not tested
Lead process safety auditorShe types the test as she would say it. The agent reads it back as a rule: piping, Class 1, thickness survey, failed when the last survey is over five years old or the record is incomplete. It runs on all 1,206 records, none sampled. The three counts add up, so the number will hold in the closing meeting.
- 0309:20
Three of the 17 late circuits have a deferral and no change record
Lead process safety auditorThe tracer follows each failure into deferrals, change records and system logs. 14 carry a signed deferral and its change record. Three do not: a debutanizer overhead, a cold separator off-gas line and a sour gas line from the stripper overhead to sulfur recovery. They light red on the wall, tag by tag.
- 04Before the test closes
Eight unread Class 1 records hold the thickness test open
Lead process safety auditorThe not-tested ledger gives each gray record a reason: 186 scans too poor to read, 94 with pages missing, 71 handwritten, 52 contractor reports that will not open, 34 tags that match nothing. Eight are Class 1 thickness records, and they block the test until a person reads them. Five have a better copy attached; three still need one.
- 0509:26
The sour gas line reaches the owner with a same-day clock
Mechanical integrity program ownerThe sour gas line has gone 7.6 years without a reading, and the agent’s arithmetic brings its wall to the minimum near the next turnaround. So the lead auditor sends an urgent referral before writing a word. It lands on the owner’s desk, due by 17:00, and blocks the signature until answered.
- 0609:38
The deferral finding waits for a checker: 11 of 238 with no change record
Audit managerThe drafting agent offered the condition and the criteria only. The lead auditor wrote the cause, the recommendation and the rating, then ran the finding across all 238 inspection date deferrals: 11 have no change record, 3 of them on Class 1 lines. It joins the audit manager’s queue beside a relief test, a dispute and four records to re-perform.
- 07Before 09:41
The checker reads the agent’s sum, marked as arithmetic
Audit managerAccept stays off until five evidence records are open: the three Class 1 lines and two of the other eight. On the sour gas line the procedure, the record and what was done sit side by side: a deferral signed by the area maintenance supervisor only, then moved to the next turnaround by a planner’s note. Below them, a rate of 0.0096 in/yr leaves 0.132 in at oil out against 0.130 in.
- 0809:44
The owner orders a thickness reading, and the finding is released
Mechanical integrity program ownerAt 09:41 the audit manager accepted the finding and released it to the owner, with a response date. The referral offers two answers: order a reading, or not yet with a reason. The owner orders one. A work order is raised in the maintenance system; its result is not back yet, and the fitness call waits for it.
- 0909:47
Across the wall, 226 failures, and 57 have nothing behind them
Lead process safety auditorThe last test is the plainest: anything past its limit, on all 24,316. 23,653 pass, 226 fail and 437 could not be tested. Of the failures, 97 carry a signed deferral and change record, 11 a deferral with no change record, 57 nothing at all and 61 a missing required item. The last three groups each have a finding.