WorkflowRegulatory Affairs

The complete guide · November 2026

CTD Module 2 authoring, explained.

A company that wants to sell a new medicine files an application with thousands of pages of study reports. A regulator starts with a much shorter part, Module 2 of the Common Technical Document, which sums up how the medicine is made and tested, the animal studies and the human trials. Every number in that summary has to match the page it came from and every other place it is stated, and each section usually has a different author.

This guide is for anyone who writes, checks, signs or pays for these summaries: regulatory and medical writers, clinical leads and clinical scientists, leads for manufacturing (CMC) and animal studies (nonclinical), submission leads, quality reviewers, and the leaders deciding whether to automate the work. No background needed.

See one case, screen by screen →
Watch with transcript →
A quick example · fictional

Imagine you are a clinical efficacy lead at a mid-size biotech, the person who answers for how well a drug works. It is Tuesday, October 6, 2026. Your company's antibody, veltrimab, for moderate to severe plaque psoriasis, goes to the US Food and Drug Administration (FDA) on December 14, 69 days from now. Six people own the 14 parts of Module 2, with 4,812 statements between them, each citing a page.

At 10:05 a.m. your colleague Sam Patel updates section 2.7.4.1 from the final report that pools the trials' safety data, dated September 9. Page 22, Table 1.2, says 1,947 patients received at least one dose. Weeks ago, Dr. Omar Haddad wrote the Clinical Overview, section 2.5.5, from a draft of that report, built on data frozen on June 30, a date called the data cut. Same table number, same page number, another figure.

2.5.5 Overview of Safety
Cites
June data cut, draft v0.9
Page
22, Table 1.2
Patients exposed
1,935
Patient-years treated
2,207
2.7.4.1 Exposure to the drug
Cites
Final report, Sep 9, 2026
Page
22, Table 1.2
Patients exposed
1,947
Patient-years treated
2,316
1,935 in the overview1,947 in the final report12 patients apart, and both sentences read well.

The reason is ordinary: 12 patients joined the extension study, VLT-303, after June 30. Nobody made a typing error. The overview was right when it was written, and nothing in a folder of Word files says it stopped being right.

Careful Module 2 work finds the sentence left behind by a newer data cut before a reviewer reads both sections.

CTD Module 2 authoring guide
Part A · Understand it

CTD Module 2 in full: seven sections, ICH page lengths, data cuts, filing risk and the 2026 AI rules

What each section holds, how long it should run, how one number goes wrong, how regulators react, and what they expect of AI, explained without selling anything. If you are new to regulatory writing, start here.

01 · In plain words

CTD Module 2 explained: the summary a regulator reads before the study reports

Before a new medicine can be sold, its maker, called the sponsor or applicant, files an application with a regulator such as the US Food and Drug Administration (FDA) or the European Medicines Agency (EMA). The application follows a shared format called the Common Technical Document, or CTD, set by the International Council for Harmonisation (ICH), so that one set of files, the dossier, can go to several regions without being rebuilt.1

The CTD has five modules. Module 1 holds each region's own forms and label. Module 3 holds the quality and manufacturing data, Module 4 the nonclinical, or animal, studies, and Module 5 the human trials. Those three modules are enormous: in our fictional example, a single clinical study report runs past 2,000 pages. So the CTD puts a summary layer on top of them, Module 2.

Its seven sections tell a reviewer what the product is, what the manufacturing data show, what the animals showed and what the trials showed, and where in the dossier to look next.1 Module 2 is written last, under the most pressure. Two of its sections are overviews, which argue what the data mean, and others are summaries, which report the data. The authors work in different teams, on different clocks, from reports that keep changing until the last data cut is final.

So the craft has two halves. One is writing: choosing what matters and saying it clearly in a few pages. The other is bookkeeping: every figure in Module 2 is a copy of a figure printed somewhere else, and the same figure often appears in several sections. When an original moves, its copies have no way of knowing.

One application, from final study reports to a regulator's first read

  1. Studies finish and reports go finalVeltrimab's clinical study report (CSR) VLT-302, 2,140 pages, goes final on August 18. The integrated safety report follows on September 9.
  2. Owners are named for each sectionSix people take the 14 separately managed parts, with December 14 as the one date.
  3. Writers draft Module 2 and check every number4,812 statements, each cited to a page. This is where 1,935 and 1,947 are caught, or carried forward.
  4. Each owner signs, and the sections go into the electronic dossier, the eCTDSix of 14 parts are signed by October 6. The rest are due by November 27.
  5. A regulator reads Module 2 firstAnything the writers missed reaches FDA's filing review and its letter at day 74, or EMA's questions at Day 120.

Step 3 is the subject of this guide. The product, people and figures in this example are fictional.

Why Module 2 may add nothing new, and three more surprises

A summary may hold only what is already filed

ICH says the Quality Overall Summary "should not include information, data or justification that was not already included in Module 3 or in other parts of the CTD".2 A freshly rounded limit or a new calculation has no place in it.

The "integrated summaries" live in Module 5

FDA says the integrated summaries of effectiveness and safety "are not summaries but rather detailed integrated analyses" that belong in Module 5.3 Sections 2.7.3 and 2.7.4 summarize them. Treating the two as one document can lead to a refusal to file, FDA's decision not to accept an application for review.

Filing can turn on whether data can be found

FDA's internal deficiency list names "Inadequate annotation in final reports or summaries of where individual studies/clinical investigations or individual data and records can be found", and "Problems with hypertext links".4

Nobody publishes how long Module 2 takes

We found no regulator, trade body or peer-reviewed study that measures weeks per Module 2 or errors per dossier. The vendor figures we saw come without a dataset. Your own last submission is the only baseline you can defend.

CTD, data cut, analysis set, source of truth

CTD and eCTD

The Common Technical Document is the five-module format. The eCTD is its electronic form: the same content as linked files with a defined structure.

Data cut

The date a study's data are frozen for an analysis. A later cut counts more patients and more time on treatment, so its tables differ.

Analysis set

The group of patients a result is calculated on. One trial has several, such as everyone randomized and the full analysis set, each with its own count.

Source of truth

The final, signed document a fact must match. A topline memo or a superseded draft may print the same table with another number.

Fourteen terms are defined in the one-page summary.

02 · The seven sections

The seven sections of CTD Module 2, and how many pages ICH expects of each

In shortICH lists seven sections in a fixed order. Two are administrative and five are the writing. Added up, ICH's expectations give about 250 to 690 pages of text, and most of that range comes from the Clinical Summary. ICH writes them as what a section should normally stay within, with tables and figures left out. They are guidance, and no regulation sets a ceiling.

"Module 2 should contain 7 sections in the following order", the guideline says, and it lists them.1 The order looks odd at first, because the two overviews come before the detailed summaries they rest on. An assessor, the regulator's reviewer, reads the overview first, and turns to the summary when a claim needs checking.

SectionWhat it doesDrawn fromICH's length guidance
2.1 Table of contentsLists Modules 2 to 5. "The TOC is only called for in the paper version of the CTD".1The dossier's structureNo entry needed for the eCTD
2.2 IntroductionThe product's pharmacologic class, mode of action and proposed useThe product"should not exceed one page"1
2.3 Quality Overall SummaryModule 3, condensed heading by heading: drug substance (S), drug product (P), appendices (A), regional (R)Module 340 pages of text; up to 80 for "biotech products" and complex processes2
2.4 Nonclinical OverviewAn integrated, critical assessment of the pharmacology, pharmacokinetics (how the body handles the drug) and toxicologyModule 4, through 2.6"about 30 pages"5
2.5 Clinical Overview"a critical analysis of the clinical data": what the results mean, benefits and risks, the basis for the prescribing informationModule 5, through 2.7"about 30 pages"6
2.6 Nonclinical Written and Tabulated SummariesWritten and tabulated summaries of pharmacology, pharmacokinetics and toxicologyModule 4 study reports100 to 150 pages for the three written summaries together; tables outside that5
2.7 Clinical Summary"a detailed, factual summarisation of all of the clinical information": biopharmaceutics, clinical pharmacology, the Summary of Clinical Efficacy (2.7.3), the Summary of Clinical Safety (2.7.4), references, synopsesModule 5 reports and integrated analyses"usually be in the range of 50 to 400 pages", attached tables excluded6
The Clinical Summary sets the size of Module 2

ICH's upper page expectation for each section's text; tables and figures excluded

2.7 Clinical Summary50 to 400400 pages
2.6 Nonclinical written summaries100 to 150150 pages
2.3 Quality Overall Summary, biotech40, or up to 8080 pages
2.4 Nonclinical Overviewabout 3030 pages
2.5 Clinical Overviewabout 3030 pages

Source 1,6,2,5 · The 2.2 Introduction adds one page. Our sum across sections: 1 + 40 + 30 + 30 + 100 + 50 = 251 at the low end, 1 + 80 + 30 + 30 + 150 + 400 = 691 at the high end.

Show the numbers
ItemUpper expectation
2.7 Clinical Summary400 pages
2.6 Nonclinical written summaries150 pages
2.3 Quality Overall Summary, biotech80 pages
2.4 Nonclinical Overview30 pages
2.5 Clinical Overview30 pages

An overview argues; a summary reports

Module 2 holds two kinds of writing. ICH says the Clinical Overview "should primarily present the conclusions and implications of those data, and should not recapitulate them".6 The comparisons in the Clinical Summary "should focus on factual observations". In the overview, ICH expects interpretation and "discussion of the place of the test drug in the armamentarium", meaning among the treatments doctors already have.6

2.5 Clinical Overview · argues

What the results mean

Conclusions, implications, benefits and risks, in about 30 pages.6

2.7 Clinical Summary · reports

What the results are

Factual observations from all the clinical information, usually in 50 to 400 pages.6

When the two blur, they start to compete: an overview that re-summarizes and a summary that interprets, each with its own version of the same table. Keeping them apart also limits how many places a number has to live. ICH encourages cross-references over repetition: "It is not intended that material presented fully elsewhere be repeated in the Clinical Overview".6

Seven sections on paper, a dozen or more files in the eCTD

ICH's granularity annex sets out how finely a dossier may divide into separate files. The Quality Overall Summary may be one document or split into drug substance and drug product parts, with one document for each drug substance. For 2.7.3, "One document for each indication should be submitted", "although closely related indications can be within a single document".1 An indication is the disease a medicine is filed to treat.

The annex's tables for 2.3 and Module 3 also depend on the version of the eCTD standard in use. Whatever you choose stays: "the same approach should be used throughout the life of the dossier", because a later change replaces a file.1

In the example, seven sections become 14 managed parts, ten of them in 2.7 and 2.3

Separately managed parts per ICH section in the fictional veltrimab dossier

2.7 Clinical Summary6
2.3 Quality Overall Summary4
2.2 Introduction1
2.4 Nonclinical Overview1
2.5 Clinical Overview1
2.6 Nonclinical summaries1

Fictional example from this guide · 2.1, the table of contents, is only called for on paper, so it has no part here.

Show the numbers
ItemParts
2.7 Clinical Summary6
2.3 Quality Overall Summary4
2.2 Introduction1
2.4 Nonclinical Overview1
2.5 Clinical Overview1
2.6 Nonclinical summaries1
03 · The rules and their dates

ICH M4, FDA and EMA rules for Module 2, and what changed by November 2026

Status as of November 2026

In shortThe format comes from ICH M4 and its three companion guidelines, unchanged for a decade on the clinical side. What is moving: the quality guideline is being rewritten, with adoption expected in June 2027; eCTD v4.0 is arriving on different clocks at FDA and EMA; FDA's drug center, CDER, revised its refuse-to-file manual in October 2025; and AI rules are still forming.

Six dates reshaped Module 2 work from 2024 to 2026, and two more are coming
  1. Jun 15, 2016M4E(R2) and M4(R4)

    Current clinical guideline and granularity annex, with tables for eCTD v4.

  2. Sep 9, 2024EMA AI paper adopted

    Product information drafted under close human supervision, with quality review before submission.

  3. May 2025M4Q(R2) draft published

    Draft Technical Document endorsed by ICH; public consultation follows.

  4. Oct 23, 2025CDER MAPP 6025.4 Rev. 1

    Refuse-to-file manual revised, with deficiency lists.

  5. Dec 22, 2025EMA: eCTD v4.0 optional

    For new applications for one EU-wide, centralized authorization.

  6. Jan 14, 2026EMA and FDA AI principles

    Ten principles of good AI practice.

  7. Oct 16, 2026FDA forward compatibility

    v3.2.2 applications may continue in v4.0.

Source 6,7,8,4,9,10,11,12

Show the numbers
WhenWhat
Jun 15, 2016M4E(R2) and M4(R4)
Sep 9, 2024EMA AI paper adopted
May 2025M4Q(R2) draft published
Oct 23, 2025CDER MAPP 6025.4 Rev. 1
Dec 22, 2025EMA: eCTD v4.0 optional
Jan 14, 2026EMA and FDA AI principles
Oct 16, 2026FDA forward compatibility
Q1 2027EMA: strongly recommended
Jun 2027M4Q(R2) adoption expected
TextWhat it asks of Module 2Status
ICH M4(R4)The seven sections and their order; acronyms "defined the first time they are used in each module"; the granularity annex. It "merely indicates an appropriate format for the data that have been acquired".1Annex revised June 15, 2016; current
ICH M4E(R2)The structure of 2.5 and 2.7, with a structured benefit-risk section at 2.5.6. Narratives should include "References or electronic links to the full report of each study".6June 15, 2016; current
ICH M4Q(R1)The outline of 2.3, with "cross-referencing to volume and page number in other Modules" and "Specification(s) from 3.2.P.5.1".2Current; the R2 revision is a draft8
ICH M4S(R2)The outline of 2.4 and 2.6, and their lengths.5December 20, 2002; current
21 CFR 314.50 and 314.101The content of a new drug application (NDA), including the integrated summaries; a filing decision within 60 days; refusal when an NDA is incomplete on its face.13,3Current
FDA eCTD guidanceUnder section 745A(a) of the Federal Food, Drug, and Cosmetic Act, covered submissions must be electronic, in a format FDA specifies. Submissions must use a supported eCTD version, "either v3.2.2 or v4.0".14,11Revision 8, September 2024; page current October 29, 2026
21 CFR Part 11For electronic records and signatures: validation, secure time-stamped audit trails, a signature's printed name, date, time and meaning, and a link between signature and record.15Current
EU centralized procedure, one authorization for the whole EUApplicants should use the eCTD; evaluation "takes up to 210 active days".16Current. The EU pharma package, a rewrite of EU medicines law, was not law on November 3, 202617,18
What is changing in the quality summary. ICH's expert group agreed new definitions and "the design of Module 2" for M4Q(R2), the second revision of the quality guideline, published the draft for consultation in May 2025, posted a mapping from R1 to R2 in December 2025, and had over 2,500 comments when consultation closed in March 2026. Its work plan, dated July 10, 2026, still expects final adoption in June 2027.8 Until a region implements the new version, a section 2.3 filed there follows R1, the current text. A sponsor with a filing planned for 2028 or later should read the draft and the mapping now.
Where eCTD v4.0 stands. FDA supports v3.2.2 and v4.0, began forward compatibility on October 16, 2026, and says it "will provide advance notice" before moving to v4.0 only. EMA has accepted v4.0 optionally for new centrally authorized applications since December 22, 2025, plans strongly recommended use from Q1 2027, and plans mandatory use from Q1 2028.11,9
04 · Sources behind each section

Which Module 3, 4 and 5 reports feed each Module 2 section, and where the ISS belongs

In shortEach Module 2 section draws mainly on one module, but clinical facts cross from section to section, and quality facts can reach the clinical overview. FDA calls one mix-up a common problem: the integrated summaries of efficacy and safety (ISE and ISS) are long analyses for Module 5, and 2.7.3 and 2.7.4 are short summaries of them.3

Clinical facts travel furthest across Module 2

How much each section depends on each source; shading is our reading of the ICH outlines

RarelySomeMain source
Module 3 qualityModule 4 nonclinicalModule 5 study reportsModule 5 integrated analyses2.3 Quality Overall SummaryMain sourceRarelyRarelyRarely2.4 Nonclinical OverviewSomeMain sourceRarelyRarely2.6 Nonclinical summariesRarelyMain sourceRarelyRarely2.5 Clinical OverviewSomeSomeMain sourceMain source2.7.1 and 2.7.2 Biopharmaceutics, clinical pharmacologySomeRarelyMain sourceSome2.7.3 Clinical efficacyRarelyRarelyMain sourceMain source2.7.4 Clinical safetyRarelyRarelyMain sourceMain source2.7.6 Study synopsesRarelyRarelyMain sourceRarely

Our reading of the sources 6,2,5 · ICH points 2.3 to supporting information from other modules, and 2.5 to pertinent animal data and product quality issues. Your dossier may differ.

Show the numbers
Module 3 qualityModule 4 nonclinicalModule 5 study reportsModule 5 integrated analyses
2.3 Quality Overall SummaryMain sourceRarelyRarelyRarely
2.4 Nonclinical OverviewSomeMain sourceRarelyRarely
2.6 Nonclinical summariesRarelyMain sourceRarelyRarely
2.5 Clinical OverviewSomeSomeMain sourceMain source
2.7.1 and 2.7.2 Biopharmaceutics, clinical pharmacologySomeRarelyMain sourceSome
2.7.3 Clinical efficacyRarelyRarelyMain sourceMain source
2.7.4 Clinical safetyRarelyRarelyMain sourceMain source
2.7.6 Study synopsesRarelyRarelyMain sourceRarely

The documents a Module 2 writer reads

DocumentCTD locationWhat Module 2 takes from itWhere it catches people
Clinical study report (CSR)5.3.5.1, and others by study typeDisposition, endpoint results, subgroup resultsInterim and final versions; several analysis sets per table
Integrated Summary of Effectiveness (ISE)5.3.5.3Pooled efficacy across studiesOften final only weeks before filing
Integrated Summary of Safety (ISS)5.3.5.3Exposure, pooled clinical-trial safety tablesExposure moves at every data cut
Statistical analysis planWith the CSRWhich analysis set and method each result usesThe plan's population name versus the sentence's
Population pharmacokinetics (PK) report5.3.3.5Exposure by weight, age, organ functionExplains subgroup results that 2.5 must discuss
Toxicology and pharmacology reportsModule 4Doses, exposures, no-observed-adverse-effect levels (the highest dose with no harm seen)A margin recalculated in the summary is a new analysis
Manufacturing, specifications, stability3.2.S, 3.2.PProcess description, limits, batch results, shelf lifeDevelopment limits and registered limits are both on file

The ISS and ISE sit in Module 5, and 2.7.4 summarizes them

FDA wrote a whole guidance on this mix-up. NDAs must contain both integrated summaries under 21 CFR 314.50(d)(5)(v) and (vi)(a). There are "no corresponding regulations" for biologics license applications (BLAs), though applicants "are encouraged to provide these analyses".3

The clinical summary sections are "subject to space limitations in the eCTD of about 400 pages, whereas a typical ISS alone often can be substantially larger". FDA names the trap: "applicants incorrectly assume that the clinical summary sections satisfy the regulatory requirement for the ISE and ISS", which "may result in a refusal-to-file action".3

FDA's model case: a 4,000-page ISS, summarized in 100 pages

FDA's Example 1, a BLA with a large ISS: pages by document part and where each belongs

ISS appendices of tables and figures, 5.3.5.33,000 pages
ISS text, 5.3.5.31,000 pages
Summary of Clinical Safety, 2.7.4100 pages

Source 3 · The same example adds 4 gigabytes of datasets in Module 5. FDA's Example 3, with the whole ISS placed in 2.7.4, ends: 'This submission is unacceptable.'

Show the numbers
ItemPages
ISS appendices of tables and figures, 5.3.5.33,000 pages
ISS text, 5.3.5.31,000 pages
Summary of Clinical Safety, 2.7.4100 pages

A narrow exception exists for small applications, where 2.7.3 or 2.7.4 can carry the narrative of the integrated summary and the appendices and datasets sit in 5.3.5.3, each location pointing to the other.3

05 · One number, worked through

How a patient count, a data cut and a specification limit go wrong in Module 2

In shortThe errors in our fictional dossier are real numbers in the wrong place: a count from another analysis set, a table from an older data cut, a limit from a development document. Each reads well and looks right next to a citation. Three worked cases from our fictional dossier show the arithmetic behind them and what each one changes.

818 or 824: one trial, two right patient counts

A trial randomizes patients, assigning each by chance to the drug or a placebo, and then some never receive a dose. ICH E9 describes the full analysis set as "as close as possible to the ideal implied by the intention-to-treat principle", "derived from the set of all randomised subjects by minimal and justified elimination of subjects".19 In plain words, that is nearly everyone randomized, with few exclusions and a reason for each.

In the fictional study VLT-302 the plan excludes anyone who never received a dose, so the table prints two rows.

Six patients separate VLT-302's randomized count from its analysis count

CSR VLT-302, page 112, Table 14.1.1.1

VeltrimabPlacebo
Randomized: 824549275
Full analysis set: 818546272

Fictional example from this guide

Show the numbers
VeltrimabPlacebo
Randomized: 824549275
Full analysis set: 818546272

The draft of 2.7.3.2 read: "In VLT-302, 818 patients were randomized 2:1 to veltrimab (n=546) or placebo (n=272)." Every number is printed in the report, and the citation points to the right table. The word "randomized" is what is wrong. The corrected sentence keeps both figures, each with its population: "In VLT-302, 824 patients were randomized 2:1 to veltrimab (n=549) or placebo (n=275); 818 received at least one dose and formed the full analysis set."

1,935 or 1,947: what twelve patients change

Exposure is the number that moves most. 2.5.5 cites the June 30 draft: 1,935 patients and 2,207 patient-years. A patient-year is one patient treated for one year. 2.7.4.1 cites the September 9 final: 1,947 patients and 2,316 patient-years.

The gap of 12 patients comes with a gap of 109 patient-years. Twelve new patients can add only a little time in a few weeks, so most of that gain must be patients already counted staying on treatment. That is our reading of the example, and it shows why both figures in a sentence have to change together. Clinical-trial tables often state rates per 100 patient-years, so every such rate has this figure underneath it.

A later data cut moves every rate built on exposure

The same 50 events, per 100 patient-years, on each cut's exposure; the 50 is an assumption, to show the arithmetic

June data cut, 2,207 patient-years2.27
Final report, 2,316 patient-years2.16

Illustrative · replace with your own numbers · 50 ÷ 2,207 × 100 = 2.27; 50 ÷ 2,316 × 100 = 2.16. A later cut normally adds events too.

Show the numbers
ItemRate per 100 patient-years
June data cut, 2,207 patient-years2.27
Final report, 2,316 patient-years2.16

100 ± 10 or 95 to 105: a limit that doubled in width

Section 2.3.P.5 of the fictional dossier states a protein concentration of 100 ± 10 mg/mL, which works out to 90 to 110 mg/mL. The registered release limit in 3.2.P.5.1, specification version 2.1, is 95 to 105 mg/mL. The summary's range is twice as wide, and it claims a limit the application does not support. ICH's instruction reads "Specification(s) from 3.2.P.5.1 should be provided", which names the place to copy from.2

As drafted in 2.3.P.5

100 ± 10 mg/mL

A development limit that survived into the summary. Range 90 to 110 mg/mL, width 20 mg/mL.

As registered in 3.2.P.5.1

95 to 105 mg/mL

Quoted exactly as registered, with its page. Range width 10 mg/mL.

06 · Six kinds of error

Six kinds of Module 2 error, and which check catches each

In shortIn our judgment, reading a sentence catches few of these errors, because the sentence reads well. Opening the cited page catches more, yet it passes a stale data cut, since the old page does print the old number. A consistency check, comparing the same fact across sections and against the source's version, catches that one.

ErrorFictional exampleWhy it happens
Copying slip2.7.3.3 said 70.1%; the CSR says 70.6%. 2.7.6 said 248 randomized in VLT-201; the CSR says 250.Numbers retyped from a report or an earlier draft
Wrong population818 called "randomized" when it is the full analysis setTables print several sets; the writer lifted the wrong row
Superseded source2.5.5 cites the June data cut, now replacedSections are written weeks apart, from the version at hand
Wrong kind of limit2.3.P.5 quotes a development range. 2.3.S.7 said 36 months' shelf life; registered is 48 months at −40 °C.Several versions of a limit are on file, all printed somewhere
Overstated wording"Consistent" across subgroups, when response above 100 kg was 61.0% against 75.9%A summary sentence flattens a nuance in the table
Untraceable claimA sentence with no page, or a link that opens the wrong fileCross-references are cut to meet a length target
Opening the cited page misses the stale data cut

How likely each kind of check is to catch each error

UnlikelySometimesLikely
Reading the sentenceOpening the cited pageSame fact elsewhereSource version checkCopying slipUnlikelyLikelySometimesUnlikelyWrong populationUnlikelyLikelySometimesUnlikelySuperseded sourceUnlikelyUnlikelyLikelyLikelyWrong kind of limitUnlikelySometimesLikelySometimesOverstated wordingSometimesLikelyUnlikelyUnlikelyUntraceable claimSometimesLikelyUnlikelyUnlikely

Our reading of the sources 4,6 · Our judgment from the error types; test it on your own dossier with planted faults.

Show the numbers
Reading the sentenceOpening the cited pageSame fact elsewhereSource version check
Copying slipUnlikelyLikelySometimesUnlikely
Wrong populationUnlikelyLikelySometimesUnlikely
Superseded sourceUnlikelyUnlikelyLikelyLikely
Wrong kind of limitUnlikelySometimesLikelySometimes
Overstated wordingSometimesLikelyUnlikelyUnlikely
Untraceable claimSometimesLikelyUnlikelyUnlikely

What published research says about summaries and about checking by eye

No regulator publishes how often Module 2 sections disagree. The nearest published evidence concerns a similar document: a short summary of a longer report written by the same people. A scoping review of 17 studies comparing journal abstracts with their full reports found a median inconsistency of 39%, with individual studies ranging from 4% to 78%, and a median of 19% for major inconsistencies where those were separated.20 Those are journals, with no filing review, so treat this as an analogy and measure your own.

Published summaries often disagree with their own full reports
39 in 100

median level of inconsistency between journal abstracts and full reports, across 17 studies (range 4% to 78%)

Source 20

Show the numbers
MeasureValue
median level of inconsistency between journal abstracts and full reports, across 17 studies (range 4% to 78%)39 of 100

Reading is also a weak way to find errors. In a study of data checking by 195 students, visual checking produced 2,958% more errors than double entry, typing the data twice and comparing, and did no significantly better than entering the data once.21 A quality reviewer re-reading 4,812 statements against their pages in the last weeks before filing is doing the kind of task the study found weak. A study of students on data sheets cannot say how far that applies to a trained reviewer.

07 · How FDA finds it

Refuse to file, the 74-day letter and review questions: where a Module 2 problem surfaces at FDA

In shortFDA decides within 60 days whether an application can be filed. Four general entries on its deficiency list concern finding data. On a refusal FDA keeps 25% of the fee, $1.15 million in fiscal 2027, and the full fee is due again when the application comes back. A smaller Module 2 problem can surface as a review issue in a 74-day letter or later questions.

Veltrimab's FDA clock, if filed on December 14, 2026

The clock under FDA's user-fee program (PDUFA) for an original BLA under standard review, applied to the example's date

  1. Dec 14, 2026Day 0: FDA receives the BLA

    eCTD sequence 0000.

Fictional example from this guide · FDA's goal is to act on 90% of standard new molecular entity (NME) NDAs and original BLAs within 10 months of the 60-day filing date, and priority applications within 6.22 A non-NME NDA's clock runs from receipt.

Show the numbers
WhenWhat
Dec 14, 2026Day 0: FDA receives the BLA
Feb 12, 2027Day 60: filing decision
Feb 26, 2027Day 74: letter
Dec 12, 2027Goal date

The four general deficiencies about finding data

CDER's review manual was revised on October 23, 2025. Under 21 CFR 314.101(d)(3) FDA may refuse to file an application that is incomplete on its face, and CDER reads that to include "when required content is presented in a form that makes it inaccessible".4 Appendix B lists complex deficiencies that may support a refusal, alone or in combination. Its general entries are:

  • "Application is unreasonably disorganized"
  • "Data tabulations (line listings) and/or graphical displays are not interpretable, are inadequately labeled, or do not indicate the sources of the data"
  • "Inadequate annotation in final reports or summaries of where individual studies/clinical investigations or individual data and records can be found"
  • "Problems with hypertext links"4

Those entries concern whether a reviewer can find things, and a filing reviewer meets them first in the summaries. Disagreement between two sections has no entry of its own, though it shows a reviewer that the summaries cannot be relied on. FDA's draft guidance says an application may be incomplete when it is "unreviewable".23 A written reason does not rescue a gap: "the mere presence of an explanation is not adequate".4

What a refusal costs in fees

A refusal costs $1.15 million in fees before any review begins

Fiscal 2027 full application fee requiring clinical data, in dollars

Fee paid with the application4,600,753
Refunded on refusal, 75%3,450,565
Kept by FDA, 25%1,150,188

Source 24,25 · Our arithmetic on FDA's fee and refund rule. A refused application pays the full fee again when resubmitted or filed over protest, at the rate then in force, unless a waiver applies.

Show the numbers
ItemDollars
Fee paid with the application4,600,753
Refunded on refusal, 75%3,450,565
Kept by FDA, 25%1,150,188

We found no regular public count of refusals. FDA's own longitudinal paper excludes refused applications from its analysis.26 What FDA does publish is how often filed applications fail their first review: a complete response, the letter that says an application cannot be approved as it stands.

More than one in four filed applications in FDA's FY2024 cohort got a first-cycle complete response

CDER original NDAs and BLAs, by receipt cohort, the four cohorts FDA's paper states one by one

47%FY2008
22%FY2018
37%FY2020
27%FY2024

Source 26 · FDA gives about 27% for FY2024 (28% in one passage) and an average of 33.7% across FY2008 to FY2024. Its paper does not tie these to summaries, and says further analysis may be needed to identify root causes. Data as of June 1, 2026.

Show the numbers
PeriodValue
FY200847%
FY201822%
FY202037%
FY202427%

FDA published more than 200 complete response letters on July 10, 2025, on applications submitted from 2020 to 2024 and since approved.27 They are public reading for any team that wants to see how FDA words its deficiencies.

08 · Outside the US

The EMA Day 120 questions, clock-stops and Health Canada's view of a poor quality summary

In shortModules 2 to 5 are common across ICH regions, so one Module 2 serves several agencies. The EU clock allows up to 210 active days, stopped while the applicant answers questions, and the first stop usually lasts three to six months. Health Canada says plainly what an inaccurate quality summary costs: more assessor time.

EMA's 210 active days stop while the applicant answers
  1. Day 1Evaluation starts

    Two lead assessment teams, the rapporteurs, work independently.

  2. Up to Day 120First questions

    The CHMP, EMA's human medicines committee, sends its questions.

  3. Clock-stopApplicant answers

    Usually 3 to 6 months, as agreed with the CHMP.

  4. LaterOutstanding issues

    A second clock-stop, if the committee needs one.

  5. By Day 210CHMP opinion

    150 days under accelerated assessment.

  6. +67 daysEuropean Commission decision

    Legally binding, within 67 days of the opinion.

Source 16,28 · EMA's booklet is dated 2019; the 210 active days are confirmed on its current page. The EU pharma package reached a provisional deal on December 11, 2025, and a Council position on September 28, 2026. On November 3, 2026, Parliament's record read "Awaiting Parliament 2nd reading", with an indicative plenary date of November 23, 2026, and no final act.17 The rules generally apply 24 months after entry into force, so about 2029 by our arithmetic.18

Show the numbers
WhenWhat
Day 1Evaluation starts
Up to Day 120First questions
Clock-stopApplicant answers
LaterOutstanding issues
By Day 210CHMP opinion
+67 daysEuropean Commission decision

A number that disagrees between sections gives an assessor one more question for that list. Each question has to be answered inside a clock-stop that the applicant has agreed, while the people who wrote the section have often moved on to the next filing.

Health Canada asks for 40 to 100 pages, and spells out why accuracy matters

Health Canada's quality guidance recommends limiting the summary to "the minimum number of pages required to summarize key information (e.g. 40-100 pages)", and offers an optional chemical-entity template. It adds: "The filing of an inaccurate or incomplete QOS will result in greater expenditure of an assessor's time in retrieving, assessing and summarizing data."29

For a synthetic drug filed in both regions, a summary within ICH's 40 pages also sits inside Health Canada's range. This guidance excludes biologics, so a biologic such as our fictional veltrimab needs a separate check.

One Module 2, many labels

Module 2 also feeds the label. A European Medical Writers Association overview notes that the Clinical Summary and Clinical Overview "provide the supporting information for the Summary of Product Characteristics (SmPC) or the product label", "so it is important these documents are consistent".30 A figure that drifts in 2.5 can drift into the prescribing information.

09 · The volume and the trend

How many applications need a Module 2 each year, and what the market data leave out

In shortPublished counts give the scale: FDA's drug center approved 46 novel drugs in 2025, EMA recommended 104 medicines, and about 65 fee-paying full-application equivalents reach FDA in an average year. Supplements and other regions add many more Module 2 updates. Nobody publishes what writing them costs.

46

new drugs never before approved or marketed in the US, approved by CDER in 2025, against 50 in 2024.31,32

FDA, Novel Drug Approvals
104

human medicines recommended for EU authorization in 2025, 38 with a new active substance.33

EMA, medicine evaluation figures
65.1

fee-paying full application equivalents a year at FDA, its weighted count of applications, the fiscal 2016 to 2025 average behind the fiscal 2027 fee.25

FDA fee notice, Table 13
Fee-paying applications to FDA swing between about 45 and 81 a year

Full application equivalents paying PDUFA fees, by fiscal year

025507510067.8
20162018202020222024

Source 25 · Waived applications are not in this count, so it understates all applications. The notice updates earlier years for refunds and waivers.

Show the numbers
Fee-paying full application equivalents
201670.5
201779.8
201868.9
201981.2
202056.8
202178.9
202245.1
202349.5
202452.9
202567.8
EMA recommended fewer medicines in 2025 than in 2024

Positive recommendations for human medicines

20242025
Recommended for authorization114 medicines104 medicines
With a new active substance46 medicines38 medicines

Source 33,34

Show the numbers
20242025
Recommended for authorization114 medicines104 medicines
With a new active substance46 medicines38 medicines
What nobody publishes. There is no public figure for weeks to a first Module 2 draft, pages in a typical Module 2, medical writers per filing, statements per section, errors found at quality review, or the size of a market for Module 2 software with a dataset behind it. Treat any such number you see as a vendor's own. Part C shows how to find yours in a week.

What a day of delay is worth: two Tufts figures from one dataset

A day of delay has two published values, both from the Tufts Center for the Study of Drug Development and one dataset of 645 drugs: about $500,000 in lost prescription sales in its journal article,35 and about $800,000 in its August 2024 white paper.36 We found no source that reconciles them. Both put direct trial cost at about $40,000 a day for Phase II and III. The white paper presents these as updates to an older, much-repeated $4 million to $5 million figure.36

The sales numbers are averages across products, measure sales and leave out costs, and were built for trial delay, so use them as a starting point for your own product's figure.

10 · What regulators say about AI

Can AI write a regulatory submission? What FDA, EMA and the GMP rules say as of 2026

Status as of November 2026

In shortNothing bans AI medical writing for submissions. FDA's draft guidance leaves drafting out of scope where it does not affect patient safety, drug quality or the reliability of results. EMA's paper, in its section on product information, expects close human supervision and a quality review of all model-generated text before submission. EU Annex 22, on AI in good manufacturing practice (GMP), is still a draft, and it concerns manufacturing. The applicant stays answerable for every word.

The rules on AI in medicines are still arriving, with dates running to 2028
  1. Sep 9, 2024EMA reflection paper adopted

    Close human supervision for AI drafting of product information.

  2. Jan 2025FDA draft guidance

    A credibility framework for models that support decisions. Still a draft.

  3. Jul 2025ISPE GAMP AI guide

    An industry framework for good-practice settings.

  4. Oct 7, 2025Annex 22 consultation closes

    The draft EU annex on AI in manufacturing.

  5. Jan 14, 2026EMA and FDA principles

    Ten principles of good AI practice.

  6. Feb 2026FDA Computer Software Assurance, final

    For device production and quality systems.

  7. Jul 27, 2026Digital Omnibus on AI in force

    Moves the EU AI Act's high-risk duties.

  8. Q4 2026Annex 22 final text targeted

    EMA's inspectors aim to give the Commission final text.

Source 37,7,10,38,39,12,40,41,42

Show the numbers
WhenWhat
Sep 9, 2024EMA reflection paper adopted
Jan 2025FDA draft guidance
Jul 2025ISPE GAMP AI guide
Oct 7, 2025Annex 22 consultation closes
Jan 14, 2026EMA and FDA principles
Feb 2026FDA Computer Software Assurance, final
Jul 27, 2026Digital Omnibus on AI in force
Q4 2026Annex 22 final text targeted
Dec 2, 2027EU AI Act: Annex III duties
Aug 2, 2028EU AI Act: Annex I duties
TextWhat it says that touches Module 2Status
FDA draft guidance on AI for regulatory decisionsSets a risk-based credibility framework for models producing information that supports decisions. It does not address "operational efficiencies (e.g., internal workflows, resource allocation, drafting/writing a regulatory submission) that do not impact patient safety, drug quality, or the reliability of results".37Draft, January 2025; FDA's page shows no final version
EMA reflection paperIn its section on product information: AI for "drafting, compiling, editing, translating, tailoring, or reviewing" should run "under close human supervision"; models are "prone to include plausible but erroneous or incomplete output"; text must be "factually and syntactically correct before submission".7 Applying this to Module 2 is our reading.Adopted September 9, 2024
EMA and FDA guiding principlesTen shared principles of good AI practice across the medicines lifecycle, which EMA says "will underpin future AI guidance".10January 14, 2026; principles
21 CFR Part 11Applies to the electronic records and signatures, however the text was written. A signed record shows the signer's printed name, date and time, and meaning; "Record changes shall not obscure previously recorded information."15Current
EU GMP Annex 11 and draft Annex 22The draft says generative AI and large language models (LLMs) "should not be used in critical GMP applications". EMA's drafting group has since discussed allowing them under a documented risk-based control strategy, with concerns remaining about what that strategy needs.39,43 The annex covers manufacturing: writing Module 2 is outside it, though it matters if the same tool writes into GMP records.Consultation closed October 7, 2025. On November 3, 2026, EudraLex Volume 4 lists no Annex 22, and Annex 11 at its January 2011 revision.12 EMA's inspectors target Q4 2026 for giving the Commission final text.42
EU AI ActRegulation (EU) 2026/1744, the Digital Omnibus on AI, moved high-risk duties: stand-alone Annex III systems to December 2, 2027, and AI in regulated products under Annex I to August 2, 2028.38 Check with counsel whether a drafting tool is high-risk at all.Published July 24, 2026; in force July 27, 2026
ISPE GAMP Guide: Artificial IntelligenceAn industry framework for AI-enabled computerized systems in regulated good-practice (GxP) settings, used with GAMP 5.41July 2025; industry guide
FDA Computer Software AssuranceCovers software used in medical device production and quality management systems, under 21 CFR Part 820.40 It is written for that scope, so a drug submission tool cannot rely on it directly.Final, February 2026

Reviewers' own tools are changing too: FDA announced an agency-wide generative AI tool on June 2, 2025.44

The published evidence on fabricated detail in clinical text

EMA's word "plausible" has data behind it. Researchers planted one fabricated detail in each of 300 clinical vignettes and tested six large language models. Under the default prompt, the models built on the fake detail about 50% to 82% of the time. A prompt written to reduce the problem, the mitigation prompt, cut the rate without removing it.45 The test used clinical decision support cases, and no Module 2 drafting was involved. The lesson that transfers is that a wrong figure reads as fluently as a right one.

A better prompt lowers fabrication and leaves plenty behind

Share of cases in which the model elaborated on one planted false detail

Default promptWith mitigation prompt
Mean of six models66%44%
Best-performing model53%23%

Source 45

Show the numbers
Default promptWith mitigation prompt
Mean of six models66%44%
Best-performing model53%23%

On the time side, one large drugmaker reported cutting a fully human-reviewed clinical study report first draft from an average of 180 hours to 80, with errors down by 50%.46 That is one company's own account of its own tool, on study reports. We found no independent published test of AI drafting on Module 2.

Which Module 2 tasks suit software

Software suits the work a person can check against a page
Stakes if wrong →
People write
Owner signs
Leave as is
Automate
Benefit-riskArgumentCross-checksFact pullingHouse styleHeadings
Ease of checking against a page →

Our reading of the sources 6,2,7 · Our judgment; your quality function may place these differently. Benefit-risk is the 2.5.6 conclusion, argument is the overview's reasoning, cross-checks compare a fact across sections, and fact pulling records each fact with its page. Upper right means software proposes and a named owner signs; upper left means people write and software checks the numbers.

Show the numbers
ItemEase of checking against a page (0–1)Stakes if wrong (0–1)
Benefit-risk0.100.68
Argument0.240.54
Cross-checks0.780.68
Fact pulling0.760.54
House style0.780.26
Headings0.620.12
11 · Three ways to automate

Templates, structured content authoring or statement-level drafting: what each reaches in Module 2

In shortRegulatory medical writing automation covers three kinds of product. Templates fix structure. Structured content authoring reuses approved text. Statement-level drafting keeps each fact with its page. They solve different problems, and many teams use more than one. Only the third can tell you that a number has stopped matching its page.

Only statement-level tools reach the checking work

How far each approach reaches each kind of Module 2 work

NoPartlyYes
Structure, styleReusing approved textPulling facts with pagesNumber agrees with pageSame fact across sectionsTemplate and style guideYesNoNoNoNoStructured content authoringYesYesNoNoPartlyStatement-level drafting with citationsPartlyNoYesYesYes

Our reading of the sources 1,6 · Our classification, by design intent; individual products vary, so test them.

Show the numbers
Structure, styleReusing approved textPulling facts with pagesNumber agrees with pageSame fact across sections
Template and style guideYesNoNoNoNo
Structured content authoringYesYesNoNoPartly
Statement-level drafting with citationsPartlyNoYesYesYes
Container

Templates and style guides

ICH's headings, numbering and house style in a locked document. Cheap, and often enough for a small sponsor filing once. A template has no link to the study reports.

Reuse

Structured content authoring

Approved text in versioned components, assembled into many documents. Strong where text repeats across regions, as it can in the "Modules 2, 3, 4, and 5" that ICH makes common to them.1 Reused text is identical, and it is right only while the component is right.

Statement

Statement-level drafting

Each fact is recorded with its population and page, each sentence points to its facts, and each page is reopened to check the claim. It solves a smaller problem, and it needs named owners and known source versions.

A tool's citation coverage says little about its citation accuracy

The common mistake in judging these tools is counting citations. Coverage asks what share of statements carry a reference. Accuracy asks what share of those references, when opened, say what the statement says. The fictional 818 sentence carried a citation to the right table: full marks on coverage, wrong on accuracy.

For the same reason, a validated system can reliably store a wrong sentence. Part 11 validation looks at "accuracy, reliability, consistent intended performance" of the system and its records.15 Whether a sentence agrees with its source is a separate measurement.

Measure 1

Coverage

Statements with a citation ÷ all statements of fact. Easy to reach, and tells you little alone.

Measure 2

Accuracy

Citations whose page confirms the value, the population and the direction ÷ citations opened.

12 · How teams do it today

Who writes and signs CTD Module 2 today, and where the working days go

In shortOwnership follows the module a section summarizes, so five functions work inside one document against one date. Writers draft, scientific owners approve, a quality reviewer re-reads numbers near the end, and a submission lead builds the eCTD. In a fictional sponsor's estimate, half the working days of a first draft go to reading, checking and reconciling.

CMC lead to submission lead: who touches Module 2

CM

Chemistry, manufacturing and controls (CMC) regulatory lead

Owns 2.3. Decides what is critical in Module 3 and quotes limits exactly as registered.

Cares about: the registered limit, every time.
NC

Nonclinical lead

Owns 2.4 and 2.6, usually a toxicologist or pharmacologist working with a writer. Carries doses and exposures exactly as printed.

Cares about: no new analysis in the summary.
CL

Clinical lead

Owns 2.5, and defends the benefit-risk argument to the regulator.

Cares about: the overview's story matching the summaries.
CS

Clinical scientist or efficacy lead

Owns parts of 2.7, working from CSRs and integrated analyses. Clinical-trial exposure moves at every data cut.

Cares about: which report version each number came from.
MW

Regulatory or medical writer

Drafts and keeps the text consistent. EMWA calls 2.5 and 2.7 the documents a medical writer is "most likely to be asked to write".30

Cares about: time to think, in the last weeks before filing.
SL

Submission lead and regulatory operations

Runs the schedule, assigns owners, builds the eCTD. O*NET lists "Coordinate, prepare, or review regulatory submissions" among regulatory affairs tasks.47

Cares about: one date, every section.

Six hand-offs between a final study report and the eCTD build

A number passes through six pairs of hands before it reaches a reviewer
  1. 1Report goes final

    CSR, ISS or Module 3 document signed; earlier versions still in folders.

    Statistics, CMCRolling
  2. 2Facts pulled

    Writers read reports and note key numbers, often in a spreadsheet.

    Medical writerWeeks
  3. 3Section drafted

    Written to template, each author from the version at hand.

    Writer and ownerWeeks
  4. 4Review cycles

    Comments from clinical, statistics, regulatory, sometimes legal.

    Section ownerWeeks
  5. 5Quality review

    Each number re-read against its source page, late in the timeline.

    Quality reviewerWeeks
  6. 6Sign-off and build

    Owners sign; links and leaves checked; the eCTD is assembled.

    Submission leadDays to weeks

Illustrative · replace with your own numbers

Show the numbers
StepWhat happensWhoTime
Report goes finalCSR, ISS or Module 3 document signed; earlier versions still in folders.Statistics, CMCRolling
Facts pulledWriters read reports and note key numbers, often in a spreadsheet.Medical writerWeeks
Section draftedWritten to template, each author from the version at hand.Writer and ownerWeeks
Review cyclesComments from clinical, statistics, regulatory, sometimes legal.Section ownerWeeks
Quality reviewEach number re-read against its source page, late in the timeline.Quality reviewerWeeks
Sign-off and buildOwners sign; links and leaves checked; the eCTD is assembled.Submission leadDays to weeks

Where 110 working days go on a first Module 2 draft

Half of a hand-written first draft goes to reading, checking and reconciling

Working days, one fictional sponsor's estimate for a 22-week first Module 2 draft

Reading Modules 3 to 5, pulling factsDrafting 2.5 and 2.7Drafting 2.3, 2.4 and 2.6Re-reading numbers against pagesReconciling figures across sections
110 working days2535202010

Illustrative · replace with your own numbers · An estimate in our fictional example, with no published benchmark behind it. Replace it with your last submission.

Show the numbers
Reading Modules 3 to 5, pulling factsDrafting 2.5 and 2.7Drafting 2.3, 2.4 and 2.6Re-reading numbers against pagesReconciling figures across sections
110 working days2535202010

In-house writers, a contract research organization or AI tools

In house

Your own writers and a shared drive

Deep product knowledge and control. The weak points: versions that drift in folders, a quality review that lands at the end, and little capacity when two filings collide.

Outsourced

Writers from a contract research organization

Capacity on demand. Knowledge has to be rebuilt each time, and the applicant stays responsible. Review cycles and source access take planning.

Software

Templates, content libraries, AI writing tools

Section 11 sets out the differences. Drafting speed is the easy part to show. The questions in Part C test how tools handle page-level evidence and a changed source.

Part B · See it working

Botminds CTD Module 2 Authoring on a fictional biologic's BLA, 69 days before filing

Part A described the work without naming a product. This part shows how Botminds does it, on the Veltrimab BLA: 14 managed parts, 4,812 cited statements, one date. Every company, person, number and document in the screens is sample data.

13 · One changed section, start to finish

From a changed exposure figure to a signed 2.7.3: one morning in the Module 2 binder

In shortThis is the example from the top of the page, inside the product. Sam Patel changes 2.7.4.1. Dr. Maya Chen opens it, and the consistency agent checks its facts live. It finds the 12-patient gap, shows both pages and drafts the fix, which goes to Dr. Omar Haddad because he owns 2.5. Then Maya fixes the disagreement in her own section and signs.

1

Module 2 as a binder, with the evidence beside every section

Tuesday, October 6. The home screen is the ICH section tree: 14 sections, 4,812 statements each cited to a page, 312 facts tracked across modules, two conflicts open, six of 14 signed. Each section shows the studies it cites, a ring for how much of it is cited and verified, and who signs.

Maya owns 2.7.3, in owner review at version 0.6 and due October 8. A conflict already sits on it: 2.7.3.2 says 818 patients randomized in VLT-302, and 2.5.4 says 824. On the right, the sign-off steps show 213 of 214 pages opened and matched.

The Module 2 binder. The section tree, a conflict with both sources side by side, the source studies and the sign-off steps for 2.7.3.
2

Sam updated 2.7.4, and exposure turns amber

At 10:05 a.m. Sam Patel, the clinical scientist, updated 2.7.4.1 Exposure to the drug. Maya opens 2.7.4, and the consistency agent checks its 29 facts against 2.5, 2.7 and Module 5: 28 match, one conflicts.

The card states it in one line: 2.5.5 says 1,935, 2.7.4.1 says 1,947, 12 patients apart. The final Integrated Summary of Safety and the June draft sit side by side, each with its version and date, and the screen names who decides: Dr. Omar Haddad owns 2.5.

A conflict across modules. Both values, both source pages, and the conflicts now open in this binder.
3

One click opens the superseded page

Maya opens what 2.5.5 cites: the Integrated Summary of Safety, June data cut, draft version 0.9, page 22 of 296, marked superseded. The passage is highlighted: 1,935 subjects, 2,207 patient-years, data cut June 30, 2026.

This page does say 1,935, so a check that only opens the cited page passes this sentence. The conflict comes from comparing facts across sections and knowing which version is the source of truth.

The cited page. Any citation opens its page at the highlighted passage, with its version and the statements that cite it.
4

The agent finds why they differ and drafts the fix

The consistency agent opens both versions of Table 1.2, finds that 12 patients enrolled in VLT-303 after the June 30 cut, and proposes a tracked change to 2.5.5, cited to the final report, page 22: "Across the program, 1,947 patients received at least one dose of veltrimab, for 2,316 patient-years of exposure."

Maya does not own 2.5, so she cannot apply it. She sends it to Omar at 10:18 a.m. The conflict stays open on the section until he applies it.

A proposed fix. The agent's steps, the tracked change with its citation, and the button that sends it to the owner.
5

2.7.3 cannot be signed while one statement disagrees

Back in her own section, 213 of 214 statements are verified. One is red. The citation verifier opened CSR VLT-302, page 112, Table 14.1.1.1, and found 824 randomized and 818 in the full analysis set.

On Facts across modules she chooses Fix with agent. It compares the populations and proposes wording that keeps both figures, then re-checks 2.5.4 and 2.7.6, which already say 824. Maya owns 2.7.3, so she applies it. Now 214 of 214 are verified, and she signs at 10:26 a.m. as Dr. Maya Chen, Clinical efficacy lead, with the meaning "Approved as section owner" and her password. The section locks as version 1.0.

Approved and locked. The corrected statement says who did what, and the history lists each agent step and each person's action with its time.
14 · Every screen

Ten more screens: the draft, the blocked signature, all 312 facts, the sources and the rules

In shortOne morning is the story. These screens show the rest: the section as a reviewer reads it, the block on signing, the facts board and its fix, the signature dialog, the sent fix, the binder afterward, every source with its version, progress against the design target, the citation rules, and a second application.

The section draft. Statements set as a reviewer will read them, each with its citation number and the verifier's verdict. The one that disagrees shows the page it was checked against.
The signature is blocked. A section cannot be signed while a statement disagrees with its source.
Sent to the owner. A fix to someone else's section goes to its owner, and stays open until applied.
Facts across modules. Every figure stated in more than one place, where it is stated, its source of truth, and what has been resolved: 41 conflicts since August in this example.
Fix with the agent. The right population, each number with its page. Nothing changes until the owner applies it.
Sign the section. What is being approved, then the signer's name, role, meaning and password.
Sources. The Module 3 to 5 documents, each with CTD location, pages, version and how many statements cite it. A statement can cite more than one source, so the column does not add to 4,812.
Progress. Weeks to first draft by section, conflicts per week, and citation status. The 5 weeks is a design target, and the 22 weeks is the fictional sponsor's baseline.
Your rules. Who signs each section, and the citation rules every statement is checked against.
A second application. Another dossier, a fictional efficacy supplement with four Module 2 sections, in the same binder.
15 · Who reads, who signs

Six agents read, draft and check Module 2; the named section owner applies changes and signs

In shortOne agent reads the sources, three draft by discipline, one opens every cited page, and one compares facts across modules. None of them applies a change or signs. Each section has a named owner, a fix to another person's section goes to that person, and a signed section locks as a version.

Source reader to consistency agent: the six Module 2 agents

Source reader

Reads CSRs, integrated summaries and Module 3 documents page by page, and records every key fact with its population and its exact page, table or figure.

Never: infers a number that is not printed.

Clinical summary writer

Drafts 2.5 and 2.7 in ICH M4E(R2) order and your template, with a citation to the source page on every statement of fact.

Never: writes a number outside the key facts register, or approves its own draft.

Nonclinical summary writer

Drafts 2.4 and the 2.6 written and tabulated summaries in ICH M4S(R2) order from the Module 4 reports.

Never: rounds or restates a dose or a no-observed-adverse-effect level.

Quality summary writer

Drafts 2.3, summarizing each 3.2.S and 3.2.P section under its matching heading.

Never: quotes a limit other than the registered one.

Citation verifier

Opens every cited page and checks the number, the population and the direction of the claim; marks each statement verified, to check, or disagrees.

Never: changes text. It proposes, and each verdict keeps the page it read.

Consistency agent

Tracks each key fact across Modules 2 to 5. When two places disagree, it opens a conflict with both values, both pages and a proposed tracked change.

Never: applies a fix or closes a conflict.

The section owner signs; the submission lead releases Module 2 to the build

Decides and signsSection ownerApplies, edits or rejects every proposed change to their section, and signs with name, role, meaning and password.
Owns the dateSubmission leadAssigns section owners, watches what is due, and releases signed sections to the eCTD build.
Sets the rulesHead of regulatory or medical writingSets citation rules, the source of truth for each fact type, house style and the Module 2 template.

Agent steps and human actions are kept apart on the section's history. A signed section is locked as a version, and a later change opens a new version with a reason. These are controls that support your compliance with 21 CFR Part 11; your own validation and procedures complete it. Botminds is SOC 2 Type II audited, with information security managed to ISO 27001.

The six people who own Veltrimab's Module 2 in the screens

Fictional, from the sample data
MC

Dr. Maya Chen · clinical efficacy lead

Owns 2.7.3 and 2.7.6. Reviews drafts, answers reviewers, signs her sections.

"Show me which number disagrees, and where it came from."
OH

Dr. Omar Haddad · clinical lead

Owns the 2.5 Clinical Overview and 2.7.1 and 2.7.2.

"If 2.5 says it, 2.7 had better say the same."
SP

Sam Patel · clinical scientist

Owns 2.7.4, working from the integrated safety report.

"Exposure numbers move every data cut."
LO

Lena Ortiz · CMC regulatory lead

Owns 2.3, written from Module 3.

"Quote the limit exactly as registered."
DO

Dana Okafor · submission lead

Owns the timeline and the eCTD build. Dr. Jonas Weber, the nonclinical lead, owns 2.4 and 2.6.

"Fourteen sections, one date: December 14."
16 · What goes in and out

Modules 3 to 5 go in; cited Module 2 sections, a citation map and signed versions come out

In shortThe solution reads what you already have: study reports, integrated summaries, Module 3 and 4 documents, your template and style guide. It returns sections ready for your eCTD build, with every citation mapped and every conflict listed. Its outcome figures here are design targets, measured in the live solution on your own dossier.

From the dossier

  • Clinical study reports, final and interim, with protocols and analysis plans (Module 5)
  • Integrated summaries of effectiveness and safety, population PK reports
  • Quality documents: process, specifications, stability, validation (Module 3)
  • Nonclinical study reports (Module 4)

From your team

  • ICH M4 templates and your style guide
  • Section owners and reviewers
  • Citation rules, p-value and decimal style
  • Source of truth for each fact type
Agents read, draft, cite and compare Every page of every source, against every fact stated in more than one place
The section owner signs
Every statement cites a page

Back to the team

  • Cited Module 2 sections, 2.2 to 2.7
  • A citation map to every source page
  • Facts across modules: conflicts with both sources
  • Owner signatures and locked versions
  • A history of every agent step and human action

Weeks to a first draft, section by section, in the fictional BLA

The design target takes each section's first draft from months to weeks

Weeks, as the Progress screen shows them: the fictional sponsor's last submission against the 5-week target for a whole first draft

By hand, last submission (fictional)With agents (design target)
2.7.4 Trial safety data18 weeks5 weeks
2.3 Quality summary16 weeks4 weeks
2.7.3 Clinical efficacy14 weeks3 weeks
2.5 Clinical overview12 weeks3 weeks
2.7.2 Clinical pharmacology9 weeks2 weeks
2.7.6 Synopses8 weeks1 week

Fictional example from this guide · Neither set is a measurement of a customer. Sections run in parallel, so these do not add up to the 22 and 5 weeks for the whole draft.

Show the numbers
By hand, last submission (fictional)With agents (design target)
2.7.4 Trial safety data18 weeks5 weeks
2.3 Quality summary16 weeks4 weeks
2.7.3 Clinical efficacy14 weeks3 weeks
2.5 Clinical overview12 weeks3 weeks
2.7.2 Clinical pharmacology9 weeks2 weeks
2.7.6 Synopses8 weeks1 week
5 weeks

to a first Module 2 draft, against about 22 weeks by hand on the fictional sponsor's last submission.

Design target
100%

of statements cited to a source page, each citation opened and checked.

Design target
312 facts

kept in step across 14 sections, re-checked when a section or a source changes.

Design target, from the sample dossier

Your template, document system and eCTD tool stay in place

Document managementStays the home of final reports. The solution reads them and records each version it read.
Regulatory information managementApplications, sequences and dates
eCTD publishingStill builds the sequence. Signed, locked sections reach it through your normal process.
Identity and single sign-onNamed owners, roles and signatures
Word and your templateKept. Headings and order follow ICH M4 and your style guide, and p-value and decimal style are settings.

Your writers stay too. Their work moves toward the argument and the review. The agents cannot approve a draft, so every section still needs an owner.

Cited to a page, compared across modules, signed by its owner

1

Every statement cites a page

A statement without a citation cannot leave drafting. A click opens the page at the passage.

2

Facts are compared across modules

The final report is the source of truth, and a changed section or source triggers a re-check.

3

Agents propose; owners decide

Only the named owner applies a change or signs, and no signature can sit over a disagreement.

Part C · Are you ready to automate?

Clinical summary authoring software: what Module 2 costs you, what it could return and how to test it

You write Module 2, or run the people who do, or answer for the date. This part is written for you: what errors and delays cost today, what automating could return, whether your team is ready, and what to ask any vendor, including us.

17 · What errors and delays cost

What a late Module 2 and a mismatched number cost a sponsor

In shortStart from your own costs. Nobody publishes the weeks Module 2 takes or how often it is wrong, so the numbers that matter are yours. A few published figures frame them: the value of a day, the fee a refusal keeps, and how often filed applications need a second cycle.

$500-800K

in lost sales for a day of delay, on average across products: two figures from one Tufts dataset. That counts sales, and your own product's figure may be far from it.35,36

Tufts CSDD, 2024
$1.15M

of the fiscal 2027 fee kept by FDA on a refusal to file, with the full application fee due again on resubmission.24,25

FDA guidance and fee notice · our arithmetic
27%

or so of CDER's FY2024 cohort of original NDAs and BLAs received a first-cycle complete response, for reasons FDA's paper does not tie to summaries.26

FDA longitudinal analysis, data as of June 1, 2026
Late-stage trial days cost the most, and a slipped filing may keep them running

Mean direct cost of a clinical trial per day, by phase

Phase III$55.7K
Phase II$23.7K
Phase IV$14.1K
Phase I$7,829

Source 36 · Tufts built these from 447 protocols' budgets for trial delay. Whether any apply to your filing depends on what keeps running while the summaries wait.

Show the numbers
ItemDollars a day
Phase III$55.7K
Phase II$23.7K
Phase IV$14.1K
Phase I$7,829
Four costs with no public figure. Hours per Module 2 section, conflicts found per filing, the share of filing issues that trace to summaries, and what a first-cycle question costs in writer time. The table below shows how to find yours.

Finding your own Module 2 baseline in a week

CostWhere it hidesHow to find your number in a week
Writer and owner hoursReading reports, pulling numbers, drafting, review cyclesTimesheets from your last filing, or ask each owner to estimate by section
Quality reviewRe-reading every number against its page, late in the timelineHours and findings from the last quality review report
ReconciliationCalls between section owners after a data cut movesCount the changes made to 2.5 and 2.7 after the final data cut
Errors that escapedNumbers that disagree in a dossier already filedPick ten facts from a filed Module 2 and trace each through every section
Agency questions74-day letters, information requests, Day 120 listsSort your last two sets of questions by whether a summary could have prevented them
Time to filingThe last weeks of Module 2 waiting on the last reportsWeeks from last report final to Module 2 signed, on your last two filings

Reviewer trust, the label, your writers' time and the next filing: costs no calculator counts

Reviewer trustA reviewer who finds one mismatch checks everything else more closely. Health Canada names the assessor time an inaccurate summary costs.29
The labelA figure that drifts in 2.5 can drift into the prescribing information.30
Your writers' last monthSpent re-reading numbers, when the overview's argument needs the most thought.
Two filings at onceA second application in the same quarter finds no spare writing capacity.
The next regionEvery later filing reopens the same facts, and the reasons behind each choice may have left with the writer.
18 · Your return

What faster Module 2 drafts return when you count writer hours against the tool's yearly cost

In shortPut in your own numbers. The calculator values the hours released on each Module 2, sets them against what the tool and your testing cost, and keeps any value of filing sooner on a separate line, because that value is the most tempting and the least certain. Every default marked illustrative is an assumption to replace.

Reading, checking, reconciling: where Module 2 saves

Reading

Facts arrive with their pages

Key facts are recorded with population and page before anyone starts a sentence.

Module 2s × hours saved reading × hourly cost
Drafting

First drafts to react to

Owners edit a cited draft and keep their time for the argument.

sections × hours saved drafting × hourly cost
Quality review

Numbers checked as they are written

Reviewers work the flagged statements and a sample of the rest.

statements × minutes saved per check ÷ 60 × hourly cost
Reconciliation

A moved number finds its copies

A new data cut lists every statement it touches, for each owner.

changes after final cut × hours each × hourly cost
Questions

Fewer avoidable questions

Conflicts found before filing cannot reach a 74-day letter.

avoidable questions × hours per response × hourly cost
Timing

Weeks back near the end

Count it only if Module 2 held the date.

days sooner × your product's value of a day

Module 2s a year, hours by section and your hourly cost

The hour defaults come from the fictional example's Progress screen: six sections at 77 section-weeks by hand and 18 at the design target, at 40 hours a week (our arithmetic). The value of a day defaults to the lower of Tufts's two published averages;35 every input marked illustrative is an assumption.

Your volume
Hours per Module 2
Your cost
Filing sooner, only if it is real
Illustrative yearly value
Module 2 time today, valued$0
Time released, valued$0
After your yearly cost$0
Hours released a year0
Hours you must release to cover your cost0
Separate line: value of filing sooner$0

Formulas, per year:
Time today = Module 2s × hours today × hourly cost
Time released = Module 2s × (hours today − hours with automation) × hourly cost
After your cost = time released − yearly cost
Break-even hours = yearly cost ÷ hourly cost; compare it with the hours released above
Filing sooner = Module 2s × days sooner × value of a day

Days sooner defaults to 0 on purpose. A filing date often depends on other things, such as the last report or a manufacturing batch, and Tufts's $500,000 to $800,000 is sales, averaged across products, and built for trial delay. Not counted: fewer agency questions, or a second filing you can now staff. Released hours are value only when you decide what they are for.

The hours saved per Module 2 decide how often you must file to break even

Module 2s a year to cover $300,000 of yearly cost, at $95 an hour

Saves 2,360 hours a Module 21.3
Saves 1,500 hours a Module 22.1
Saves 800 hours a Module 23.9

Illustrative · replace with your own numbers

Show the numbers
Hours savedModule 2s a year
Saves 2,360 hours a Module 21.3
Saves 1,500 hours a Module 22.1
Saves 800 hours a Module 23.9
The design target saves the most days on drafting and the largest share on reading

Working days on a first Module 2 draft, by kind of work

By hand (fictional estimate)With agents (design target)
Reading Modules 3 to 5, pulling each fact25 days3 days
Drafting 2.5 and 2.735 days8 days
Drafting 2.3, 2.4 and 2.620 days5 days
Re-reading numbers against pages20 days4 days
Reconciling figures across sections10 days5 days

Fictional example from this guide · 110 working days against 25. An estimate and a target: measure both on your own filing.

Show the numbers
By hand (fictional estimate)With agents (design target)
Reading Modules 3 to 5, pulling each fact25 days3 days
Drafting 2.5 and 2.735 days8 days
Drafting 2.3, 2.4 and 2.620 days5 days
Re-reading numbers against pages20 days4 days
Reconciling figures across sections10 days5 days

A sponsor that files one application every two or three years may be better served by a template and a disciplined quality review. A sponsor or contract research organization with several filings and supplements a year passes the 1.3 Module 2s on the chart's top line, provided a pilot confirms the hours.

Start here19 · Readiness check

How ready your regulatory writing team is: filings, source control, owners, findings and sign-off

In shortPick the answer closest to your team today. Eight questions score 0 to 2; the last is for reflection. The meter adds up your score as you go, and each question says why it matters and what a strong answer sounds like.

1
Filings ahead

How many Module 2 first drafts or major updates does your team expect in the next two years?

Why it mattersVolume sets the return. One filing every few years rarely covers the cost of a new tool.
A strong answer"Two original applications and three efficacy supplements, one of them in the EU."
2
Your Module 2 baseline

Do you know your weeks to a first draft, by section, and how many conflicts your last quality review found?

Why it mattersNo public benchmark exists, so your own baseline is the only way to prove an improvement.
A strong answer"Twenty weeks to first draft last time, and 37 numeric findings in quality review."
3
Source versions

Can you say, for any report, which version is final and which earlier versions are still in circulation?

Why it mattersSoftware can only hold a fact to the source of truth if the source of truth is known.
A strong answer"Final reports live in the document system with status and date. Drafts are marked superseded."
4
Section owners

Does each Module 2 section have one named owner who applies changes and signs?

Why it mattersA system that proposes changes needs somewhere to send them. Committees cannot apply a tracked change.
A strong answer"Six named owners, assigned at kickoff, and the submission lead holds the list."
5
Findings on file

Have reviewers, an agency or audit questioned Module 2 traceability or consistency in your last two filings?

Why it mattersFindings bring budget. FDA's deficiency list names summaries that do not say where data can be found.4
A strong answer"A 74-day letter asked us to reconcile two exposure figures, and we lost a month."
6
House rules on paper

Are your citation rules, p-value style, decimal places and template written down in one place?

Why it mattersThese become settings. A rule that lives in people's heads cannot be applied across 14 sections.
A strong answer"One style guide, owned by the head of medical writing, updated last year."
7
Sponsor and budget

Is there a named sponsor for Module 2 writing with a budget to change how it is done?

Why it mattersModule 2 crosses clinical, nonclinical, CMC, statistics, regulatory operations and quality. Without one sponsor it stalls.
A strong answer"Our head of regulatory affairs sponsors it, and writing vendor budget can move."
8
AI and Part 11 path

Do you have a way to approve AI in regulatory writing: a quality review of the output, Part 11 validation and a written context of use?

Why it mattersEMA's paper asks for close human supervision and quality review of product information documents, and applying that here is our reading.7 Validation of the system and checks on the text are separate.15
A strong answer"Quality has a path for AI tools, and a one-sentence context of use for each."
9
Vision · for reflection

If a reviewer asked tomorrow where the exposure figure in your last Clinical Overview came from, and where else you state it, how long would the answer take?

Why it mattersYour answer lists the gaps. Each gap is a candidate job for software: finding the page, finding the copies, or tracking the version.
A strong answerA short, specific list, for example: "every fact with its page, one register of shared facts, and a re-check when a source changes."

A low score means naming section owners and final sources first

0–6

Explore

Build the baseline first: trace ten facts through a filed Module 2, write down your rules, and name owners on the next filing. A template and a shared key facts list may be all you need for now.

7–11

Ready to pilot

Run a seeded test on a closed submission, with planted faults and a superseded report left in the sources. Compare catches, false flags and minutes with your own quality review.

12–16

Ready to implement

Plan the live filing: owners and rules as settings, document system and eCTD links, Part 11 validation, and when in the timeline the first full check runs.

20 · Questions for any vendor

What to ask vendors of regulatory writing software about citations, superseded data cuts and who signs

In shortAsk every vendor the same questions, us included. The answers show how a statement is built, whether its citation has been opened, what happens when a source changes, who may apply a change, and how you would measure all of it on your own dossier.

AskA good answerA warning sign
What it reads
Does it read Module 3 and 4 documents as well as CSRs, with tables?All three modules, every table, each value with its pageClinical text only, or "we summarize the whole document"
Where does a number in a draft come from?From a recorded fact, with population, page and tableGenerated in the sentence, with a reference added afterward
What does it do with a number it cannot find printed?Leaves it out and says soCalculates or infers it silently
Citations
Does a citation open the page at the passage?Yes, in one click, with version and dateA document name, or a page number to look up
Is each citation opened and checked, separately from the drafting?A separate check of value, population and direction, with a verdict kept"Every sentence has a citation", as the only evidence
Can it tell 818 randomized from 818 in the full analysis set?It compares the population named in the sentence with the row in the tableIt matches the number and stops
Consistency and changed sources
How does it know that 2.5.5 and 2.7.4.1 state the same fact in different words?A register of facts, with each statement linked to its entrySearch for identical text
What happens when a report gets a new version?The old version is marked superseded, and affected statements are listed for each ownerA person re-uploads and re-runs everything
What does it do with a statement citing a superseded page?Opens a conflict naming both versionsPasses it, since the page does say that
Who decides
Can the software change a section on its own?It proposes tracked changes, and only the section's owner applies themAuto-corrections, with a log
Can a section be signed while a statement disagrees with its source?No, and the block shows the pageA warning anyone can dismiss
What does a signature record?Printed name, date, time and meaning, bound to a locked version15A status field called "approved"
Your data and AI
Where do our unpublished study data go, and are they used to train anything?A named environment, contractually excluded from trainingA general privacy page
What evidence supports validation under Part 11, and what stays our job?A clear split of supplier and customer duties, and audit reports"The product is Part 11 compliant"
Which credentials can you show?Named audits you can read, with dates and scope"GxP certified", which no product can be
Proof
Will you run on our closed submission with faults we planted?Yes, and you grade the results against the pageA demonstration on prepared documents only
What is your false-flag rate on clean text?Measured by section type, and you can test itOnly a catch rate is quoted

We found no published independent test of any Module 2 tool's accuracy, as of November 2026. A planted-fault test on your own closed submission is the fairest comparison, and the same test measures your current quality review.

21 · How to start

Test Module 2 software on a closed submission with planted faults, then decide on four numbers

In shortMeasure first, then test on a closed submission whose answers are settled, with faults you planted and a superseded report left in. Then run alongside one live section. None of these steps commits you to a vendor, and the test measures your current process as well.

  1. Trace ten facts through a filed Module 2: patients randomized, patients exposed, a key result, a specification limit. That is your baseline for escaped conflicts.
  2. Choose a closed submission and two sections: one numeric, such as 2.7.3, and one argument, such as 2.5. Keep the data in the environment your agreements require.
  3. Plant 40 faults from your own quality history: wrong population, superseded source, rounding, development limit, overstated wording. Lock the key, and keep planted text away from any live dossier.
  4. Run and grade: two graders who did not choose the tool, against the page, with a third to settle disputes. Sample 60 unflagged statements too, to see what was missed.
  5. Decide with four numbers: citation accuracy, catch rate by fault type, false flags on clean text, and owner minutes to a section they are willing to sign.
A twelve-week pilot ends with a decision on four numbers
Your teamVendor
Trace ten facts; gather quality findings
Choose submission; plant 40 faults; lock the key
Load sources; set rules and template
Run on two closed sections
Grade against the page
Parallel run on one live section
Report four numbers and decide
Week 04812

Illustrative · replace with your own numbers

Show the numbers
ActivityFromTo
Trace ten facts; gather quality findings02
Choose submission; plant 40 faults; lock the key14
Load sources; set rules and template35
Run on two closed sections57
Grade against the page69
Parallel run on one live section811
Report four numbers and decide1112

Citation accuracy, catch rate and false flags per planted fault

MeasureHowWhy
Citation accuracyCitations whose page confirms value, population and direction ÷ citations opened, per sectionCoverage can be full while accuracy is poor
Catch rate by fault typePlanted faults found ÷ planted, per type, with the number plantedOne percentage hides the wrong-population faults
Stale-source catchStatements citing the superseded report that were flaggedThe fault that opening a page cannot find
False flagsTrue statements flagged ÷ true statements, in reviewer minutesA tool that flags everything catches every plant
Owner minutes to signTime from draft to a section the owner will sign, checking includedA fast draft with a slow check saves nothing
Findings you did not plantA list, each confirmed against its pageOften the clearest evidence of what the tool adds
The full working-session questions: 12 questions in four groups

Bring regulatory affairs, medical writing, clinical, CMC, nonclinical, statistics, quality and IT into one room. Each question says why it matters, what a strong answer looks like, and the warning sign.

A

Filings, sections and who owns each

A1

Which filings and supplements fall in the next 24 months, in which regions?

Why it mattersSets the volume and the eCTD versions you will meet.9
Strong answer · warning sign
A dated list, by region.
"It depends on the data."
A2

What is our Module 2 granularity, and is it fixed for the life of each application?

Why it mattersICH expects the choice to stay.1
Strong answer · warning sign
A written choice per product.
Decided by each publisher.
A3

Who applies a change to 2.5, and who signs it?

Why it mattersProposals need a destination.
Strong answer · warning sign
One name per section.
"The clinical team."
B

Final reports, data cuts and the source of truth

B1

Which document is the source of truth for each fact type?

Why it mattersThis is the setting everything else checks against.
Strong answer · warning sign
A short table: CSR, ISS, 3.2.P.5.1.
"Whatever is latest."
B2

What happens to Module 2 when a data cut moves after drafting starts?

Why it mattersStale statements come from here.
Strong answer · warning sign
A listed re-check with an owner.
An email to the team.
B3

Are the ISE and ISS planned for Module 5, with 2.7.3 and 2.7.4 summarizing them?

Why it mattersFDA warns of the mix-up.3
Strong answer · warning sign
Both planned at 5.3.5.3.
"2.7.4 covers it."
C

Quality review findings and agency questions

C1

What did the last quality review find, by type?

Why it mattersThis is your fault list.
Strong answer · warning sign
Counts per type.
"Mostly formatting."
C2

Which agency questions on the last filing trace to a summary?

Why it mattersSizes the avoidable rework.
Strong answer · warning sign
A list, with hours.
Nobody has looked.
C3

Are hyperlinks in the summaries tested before the build?

Why it mattersA named deficiency entry.4
Strong answer · warning sign
Tested on each sequence.
Left to the publisher, at the end.
D

Part 11, AI approval and data handling

D1

What is our one-sentence context of use for an AI drafting tool?

Why it mattersRisk is judged against it in FDA's framework, which is also a useful test outside its scope.37
Strong answer · warning sign
Narrow, testable, names who decides.
"It writes Module 2."
D2

Who validates the system, and against which specification?

Why it mattersPart 11 asks for it; the pilot covers what validation does not.15
Strong answer · warning sign
Quality owns a plan.
"The vendor is compliant."
D3

Do our agreements allow study data in the chosen environment?

Why it mattersUnpublished results and patient-level data carry duties.
Strong answer · warning sign
Reviewed by legal before the pilot.
Found out in week three.
22 · Frequently asked questions

CTD Module 2 questions answered: sections, page limits, QOS, ISS, refuse to file and AI

In shortThe questions writers and buyers search for most, each answered on its own.

What is CTD Module 2?

CTD Module 2 is the summary layer of a Common Technical Document, the format the International Council for Harmonisation (ICH) set for marketing applications. It has seven sections: table of contents, introduction, Quality Overall Summary, Nonclinical Overview, Clinical Overview, Nonclinical Written and Tabulated Summaries, and Clinical Summary. A regulator reads it first, then goes to Modules 3, 4 and 5 for the detail.

How many pages should CTD Module 2 be, and are there page limits?

Adding ICH's expectations gives about 250 to 690 pages of text: one page for the introduction, 40 for the Quality Overall Summary (up to 80 for biotech products), about 30 each for the two overviews, 100 to 150 for the nonclinical written summaries, and 50 to 400 for the Clinical Summary. Tables and figures are left out of those counts. ICH words most of them as what a section should normally or generally stay within, and they are guidance, with no regulation setting a ceiling.

What is the difference between the Clinical Overview and the Clinical Summary?

The Clinical Overview, section 2.5, is a short critical analysis of about 30 pages: what the results mean, the benefits and risks, and the reasoning behind the prescribing information. The Clinical Summary, section 2.7, is a longer factual summary of all the clinical information, usually 50 to 400 pages. ICH asks the overview to cross-refer to the summary and not repeat it.

What goes in the Quality Overall Summary?

The Quality Overall Summary, section 2.3, follows Module 3's outline: drug substance, drug product, appendices and regional information. It emphasizes critical key parameters and cross-refers to the data, and it may include nothing that is not already in Module 3 or elsewhere in the dossier. Specifications should be taken from 3.2.P.5.1 as registered.

Is there a Quality Overall Summary (QOS) template?

ICH's M4Q guideline is itself the outline: every heading with an instruction on what to carry up from Module 3. Health Canada also publishes an optional template for chemical entities. ICH's draft M4Q(R2) will change the design, with adoption expected in June 2027 according to its work plan of July 2026. Until a region implements it, filings there follow M4Q(R1).

Where does the Integrated Summary of Safety go in the CTD?

The full Integrated Summary of Safety goes in Module 5, section 5.3.5.3, with the Integrated Summary of Effectiveness. FDA's 2009 guidance says they are detailed analyses rather than summaries, and that section 2.7.4 and section 2.7.3 summarize them in Module 2. Assuming the Module 2 sections meet the new drug application (NDA) requirement can lead to a refusal to file.

Who writes CTD Module 2?

Usually several people. A chemistry, manufacturing and controls (CMC) regulatory lead owns the Quality Overall Summary, a nonclinical lead owns 2.4 and 2.6, a clinical lead owns the Clinical Overview, and clinical scientists or efficacy leads own parts of the Clinical Summary, often with regulatory or medical writers drafting. A submission lead holds the date and builds the electronic dossier, the eCTD.

Can inconsistent data cause an FDA refuse to file?

The review manual of FDA's drug center, CDER, revised October 23, 2025, lists among its general deficiencies an unreasonably disorganized application, tabulations that do not indicate the sources of the data, summaries lacking annotation of where data can be found, and problems with hypertext links. Inconsistency has no entry of its own. A mismatch short of those problems can surface as a review issue in FDA's 74-day letter or later questions.

What does an FDA refuse to file cost?

FDA refunds 75% of the paid application fee, so at the fiscal 2027 fee of $4,600,753 it keeps $1,150,188. The full fee is due again when the application is resubmitted or filed over protest, unless a waiver applies. Time is lost too, because the corrected application goes through filing again.

Does the FDA allow AI to write a regulatory submission?

Nothing in FDA's rules bans it. FDA's January 2025 draft guidance leaves out AI used for drafting a submission where it does not affect patient safety, drug quality or the reliability of study results, and encourages early contact if a sponsor is unsure. As of November 2026 that guidance is still a draft, and the applicant stays responsible for every statement.

What does the EMA say about AI drafting regulatory documents?

EMA's reflection paper, adopted in September 2024, says AI used to draft or review product information documents should run under close human supervision, because generative models can give plausible but wrong or incomplete output. It asks for quality review so that text is factually and syntactically correct before submission. That section names product information documents, so applying it to Module 2 is our reading.

Does 21 CFR Part 11 apply to AI-drafted sections?

Part 11 applies to the electronic records and signatures, however the text was written. A signed record must show the signer's printed name, the date and time, and the meaning of the signature, and audit trails must not obscure earlier entries. No software can be certified as Part 11 compliant on its own: controls in a product support your compliance, alongside your validation and procedures.

What is eCTD v4.0, and when is it required?

eCTD v4.0 is a newer version of the electronic submission standard. FDA supports v3.2.2 and v4.0, began forward compatibility on October 16, 2026, so applications begun in v3.2.2 may continue in v4.0, and says it will give advance notice before moving to v4.0 only. EMA has accepted it optionally for new centrally authorized applications since December 22, 2025, plans strongly recommended use from Q1 2027, and plans mandatory use from Q1 2028.

How long does it take to write CTD Module 2?

No regulator or study publishes a figure. Time depends on the size of the clinical program and when the last reports go final, and much of it goes to reading and checking. Your own last submission is the only reliable baseline: take the weeks from last report final to Module 2 signed, section by section.

23 · One-page summary

CTD Module 2 on one page: the method, the November 2026 rules, readiness and terms

Print this page

In shortThe whole guide on one screen: the method, the rules as of November 2026, the readiness questions and the terms.

The method
  1. Name one owner per section and one source of truth per fact type.
  2. Record each key fact with its population, version and page before drafting.
  3. Draft to ICH's outline: overviews argue, summaries report, nothing new appears.
  4. Open every cited page: check the value, the population and the direction.
  5. Compare every shared fact across sections, and against the final source.
  6. Re-check when a section or a source changes; run the pass again after the last report goes final.
  7. Sign with name, date, time and meaning; lock the version; a later change opens a new one.

Readiness: score 0–2 on eight questions: 0–6 explore · 7–11 pilot · 12–16 implement.

As of November 2026: M4E(R2) and M4(R4) current · M4Q(R2) draft, adoption expected June 2027 · FDA supports eCTD v3.2.2 and v4.0 · EMA v4.0 mandatory planned Q1 2028 · FDA's AI guidance a draft · Annex 22 a draft · EU pharma package not yet law.

14 terms
CTD · eCTD
The five-module dossier format, and its electronic form.
QOS
Quality Overall Summary, section 2.3.
Clinical Overview
Section 2.5: critical analysis, about 30 pages.
Clinical Summary
Section 2.7: factual, usually 50 to 400 pages.
CSR
Clinical study report, one per trial, in Module 5.
ISE · ISS
Integrated analyses of effectiveness and safety, in Module 5 at 5.3.5.3.
Data cut
The date a study's data are frozen for an analysis.
Analysis set
The group of patients a result is calculated on.
Full analysis set
As close to all randomized patients as justified exclusions allow.
Patient-year
One patient treated for one year.
Granularity
Which parts of the CTD are separate files, kept for the application's life.
Refuse to file
FDA's decision, within 60 days, that an application cannot be filed for review.
74-day letter
FDA's note of filing review issues and the planned review timeline.
Clock-stop
A pause in EMA's 210 active days while the applicant answers questions.
24 · Sources

Sources

Accessed November 2026. Regulatory status statements are as of November 2026.

  1. ICH, M4 Organisation of the Common Technical Document, M4(R4), with Annex: Granularity Document, June 15, 2016. database.ich.org
  2. ICH, M4Q(R1) The Common Technical Document: Quality, Step November 4 9, 2000, numbering edited September 12, 2002. database.ich.org
  3. FDA, Integrated Summaries of Effectiveness and Safety: Location Within the Common Technical Document, guidance, April 2009. fda.gov
  4. FDA CDER, MAPP 6025.4 Rev. 1, Good Review Practice: Refuse to File, effective October 23, 2025. fda.gov
  5. ICH, M4S(R2) The Common Technical Document: Nonclinical, December 20, 2002. database.ich.org
  6. ICH, M4E(R2) The Common Technical Document: Efficacy, June 15, 2016. database.ich.org
  7. EMA, Reflection paper on the use of artificial intelligence in the medicinal product lifecycle, adopted by CHMP September 9, 2024. ema.europa.eu
  8. ICH, M4Q(R2) Expert Working Group Work Plan, July 10, 2026. database.ich.org
  9. EMA, eSubmission: eCTD, timelines for eCTD v4.0. esubmission.ema.europa.eu
  10. EMA, EMA and FDA set common principles for AI in medicine development, January 14, 2026. ema.europa.eu
  11. FDA, Electronic Common Technical Document (eCTD), content current as of October 29, 2026. fda.gov
  12. European Commission, EudraLex Volume 4, read November 2026. health.ec.europa.eu
  13. 21 CFR 314.101, Filing an NDA and receiving an ANDA. govinfo.gov
  14. FDA, Providing Regulatory Submissions in Electronic Format: Certain Human Pharmaceutical Product Applications Using the eCTD Specifications, Revision 8, September 2024. fda.gov
  15. 21 CFR 11.50, Signature manifestations, govinfo.gov; 21 CFR 11.10, Controls for closed systems, govinfo.gov; and 21 CFR 11.70, Signature/record linking.
  16. EMA, Obtaining an EU marketing authorisation, step by step. ema.europa.eu
  17. European Parliament, Legislative Observatory, procedure files 2023/0131(COD) and 2023/0132(COD), read November 3, 2026. europarl.europa.eu
  18. CMS, EU Pharmaceutical Package: what the Council's revised texts mean for companies, October 2, 2026. cms.law
  19. ICH, E9 Statistical Principles for Clinical Trials, February 5, 1998. database.ich.org
  20. Li et al., "A scoping review of comparisons between abstracts and full reports in primary biomedical research", BMC Medical Research Methodology, 2017. doi.org
  21. Barchard and Pace, "Preventing human error: The impact of data entry methods on data accuracy and statistical results", Computers in Human Behavior 27(5), 2011. doi.org
  22. FDA, PDUFA Reauthorization Performance Goals and Procedures, Fiscal Years 2023 Through 2027. fda.gov
  23. FDA, Refuse-to-File: NDA and BLA Submissions to CDER, draft guidance, December 2017. fda.gov
  24. FDA, Assessing User Fees Under the Prescription Drug User Fee Amendments of 2022, guidance, July 2023. fda.gov
  25. FDA, Prescription Drug User Fee Rates for Fiscal Year 2027, FR Doc. 2026-15334, published July 30, 2026. federalregister.gov
  26. FDA CDER, First-Cycle Complete Response Rates for CDER NDA and BLA Applications: A Longitudinal Analysis, FY 2008–2024, data as of June 1, 2026. fda.gov
  27. FDA, FDA Embraces Radical Transparency by Publishing Complete Response Letters, July 10, 2025. fda.gov
  28. EMA, From laboratory to patient: the journey of a centrally authorised medicine, 2019. ema.europa.eu
  29. Health Canada, Guidance Document: Quality (Chemistry and Manufacturing) Guidance, New Drug Submissions and Abbreviated New Drug Submissions. canada.ca
  30. Jordan, overview of the Common Technical Document, Medical Writing 23(2), European Medical Writers Association, 2014. emwa.org
  31. FDA, Novel Drug Approvals at FDA: 2025. fda.gov
  32. FDA, Novel Drug Approvals at FDA: 2024. fda.gov
  33. EMA, Medicine evaluation figures, 2025 overview. ema.europa.eu
  34. EMA, Human medicines in 2024. ema.europa.eu
  35. Smith, DiMasi and Getz, "New Estimates on the Cost of a Delay Day in Drug Development", Therapeutic Innovation & Regulatory Science 58(5), 855-862, 2024. doi.org
  36. Smith, DiMasi and Getz, Quantifying the Value of a Day of Delay in Drug Development, Tufts Center for the Study of Drug Development white paper, August 2024. csdd.tufts.edu
  37. FDA, Considerations for the Use of Artificial Intelligence to Support Regulatory Decision-Making for Drug and Biological Products, draft guidance, January 2025. fda.gov
  38. Lewis Silkin, The Digital Omnibus on AI enters into force today, July 27, 2026, on Regulation (EU) 2026/1744 (OJ:L_202601744). lewissilkin.com
  39. European Commission, Stakeholders' consultation on EudraLex Volume 4: Chapter 4, Annex 11 and new Annex 22, July 7 to October 7, 2025. health.ec.europa.eu
  40. FDA, Computer Software Assurance for Production and Quality Management System Software, final guidance, February 2026. fda.gov
  41. ISPE, GAMP Guide: Artificial Intelligence, July 2025. ispe.org
  42. EMA, 3-year work plan of the GMDP Inspectors Working Group. ema.europa.eu
  43. EMA, Good manufacturing practice: multistakeholder workshop on expert contributions to AI guidance development (Annex 22), report of the June 30, 2026 meeting. ema.europa.eu
  44. FDA, FDA Launches Agency-Wide AI Tool, June 2, 2025. fda.gov
  45. Omar, Sorin, Collins, Reich et al., "Multi-model assurance analysis showing large language models are highly vulnerable to adversarial hallucination attacks during clinical decision support", Communications Medicine 5:330, August 2025. doi.org
  46. Merck, company press release on internal generative AI for clinical study reports, June 25, 2025 (company-reported). merck.com
  47. O*NET OnLine, Regulatory Affairs Specialists, 13-1041.07. onetonline.org
Next step

Check a closed Module 2 against its study reports.

Explore the solution, or bring a closed submission's sources and Module 2 drafts, and we will check them with you, every statement opened at its page.

botminds.ai The complete guide to CTD Module 2 authoring · November 2026. Veltrimab, Dravenzo, Talvoren, their studies, every person and every figure in the example and the screens are fictional. Regulatory status is as of November 2026; check the sources before relying on it.